Revision 1 r " s U.S. NUCLEAR REGULATORY COMMISSION September 1978 m,

Ef. REGU _K'ORY G U D E t

OFFICE OF STANDARDS DEVELOPMENT REGULATORY GUIDE 3.8 PREPARATION OF ENVIRONMENTAL REPORTS FOR URANIUM MILLS 9

142 i86

"*',ts sN.mni t e sam to is, sas., tar y n' +e commisse U s h. ear USNRC REGULATORY GUIDES pq,4tw Commewe A a*Nnc e' DC 2'W6 A *t ew.o.

D = b e'w a c peqv att < v G s Ws ava sw;*1 to <1es, r tie cri.1 ma.a av a-w..w

'> toe UUtk serw e Br erx h metN w+s +'r eptatr+c to ter 'v D C Ca**

r..f emtw.r wyq.ng gy,fs u r+ g c>e ts, Cive4%c m S rag,. gf Hrs f 4.1 riervrwA's tei-tv1 h.#% Unc ) by the gi a *',n p, q%

I N* glid!P18 e F%gite']

  • the8:# riming fer (wra j h vi rrig at rs; 4 4=4 poet. em. :w amtvint =1 aroijents tw to perv.<1,.a. mia ry, to I

b' '*#' b 9d' *f *f s b b flUL '%

ADL a s dt%

bhJu*.9t' ry C u 't je*4 4F P r W'sf gut 4f-f y *pg lyr e pg,1.4'& g go.-j ipm

b 8'%Oa##r arvi T esi ew I s s 7 T ' a n ww w' 4'a in

[1M 9 A'th th#r" 'S fMit 8 Arji,W40sj M$tNbjgghj yp, g{g ypg cji t

ofpr prij $g p ty.gp 3 F 'de'% aD*iA8U # d 3$O' d fle%

h 08f b N'W W.W HM'h SPt r%fO %# QtsN)*% A'Il IA 54r,. Pp*M 48 6f I' hey pg.3yy}p g (qgsq fi pp The firy tr,g g r

4 k "Wdf

    • M 4M S ' y q An i st am1 6. > > a

,a P orjil'9M# '

ft'e %3drit 4 (4 Czw ' 62d v e (,f g upy m.f (w

,,arge h me (OF1rDr41 Ori h M st'Pf d5% a' ';T UdD$ b f. T AEFInr l) b mOHr GI

( s.rmn pf'!g druj ggg lpg[q og top errs pr og pft,p r$'3 mr1 f t pgp 4.,,r'eg gp prh( bi af d jm1 Rfk] s#%'s f d er ge ar.(.pg.: $, gg.,de. j y,j < jpg Ah g(

'9 NJy (ws p(bf ia

,a Pe ' l v' 4'W v"

p,sc ter"t m a.,

4,T pate ijs's t %t oor 4,,1 64 ? eg.e r op.es of qui te-s de #1 ' +es ami a r!*s WiH be raw se ? as ar(<qw n'y to a. r re-wwja's r r

t a epf,e r,pv, if or m4 r g,e

,w pa geni #F'48 M ' %envast t' Wimporg rnr g pe it.g.

.j, s it,g OF I ? he r*iAi!p r1 we f.I'Q fr 'he V.,

%i mA* P e< p,ld mer'eg yw] f,3 i

..,'a.-e.?%,++

aN.

'v o mo mg af+ ne.ts isso y. c

.,o te C r,m viw. w, W agh,q+

CC Mg Atsart e

),es ti g D., s a

id it'.s goi *

  • d gi st i go j O g e prf [ j t f

id Wi my y f o rg.or I p. hne. 4. P 8 F. h bd.OQ '* P ficeil l

[qtf th" sid P b

,%P'.,

79071109 7&*

TABLE OF CONTENTS Pa ff A.

INTRODUCTION IV 1.

National Environmental Goals iv 2.

Applicant's Environmental Reports.

vi 3.

Preparation of Environmental Reports viii B.

STANDARD FORMAT AND CONTENT OF ENVIRONMENTAL REPORTS FOR URANIUM MILLS.

1-1 CHAPTER 1 PROPOSED ACTIVITIES.

1-1 CHAPTER 2 THE SITE 2-1 2.1 Site Location and Layout 2-1 2.2 Uses of Adjacent Lands and Waters.

2-2 2.3 Population Distribution.

2-4 2.4 Regional, Historic, Archeological, Architectural, Scenic, Cultural, and Natural Landmarks.

2-5 2.5 Geology.

2-6 2.6 Seismology

?

2-7 2.7 Hydrology.

2-7 2.7.1 Ground Water.

2-7 2.7.2 Surface Water 2-8 2.8 Meteorology.

2-8 2.9 Ecology.

2-10 2.10 Background Radiological Characteristics.

2-12 2.11 Background Nonradiological Characteristics 2-12 2.12 Other Environmental Features 2-12 CHAPTER 3 THE MILL AND MINE(S) 3-1 3.1 Site Area.

3-1 3.2 External Appearance of Mill.

3-2 3.3 Mill Circuit 3-2 3.4 Sources of Mill Wastes and Effluents 3-2 3.5 Controls of Mill Wastes and Effluents.

3-3 3.6 Sanitary and Other Mil) Waste Systems.

3-4 3.7 Mining Activities.

3-4 CHAPTER 4 ENVIRONMENTAL EFFECTS OF SITE PREPARATION, MILL CONSTRUCTION, AND MINE OPENING 4-1 4.1 Site Preparatiori and Construction.

4-1 4.2 Resourtes Commi tted.

4-3 1

142 187

TAfuE OF CONTENTS (continued)

P3M CllAPTER 5 ENVIRONMENTAL EFFECTS OF MILL AND MINE OPERATION

) - 1 5.1 Radiological Impact on Biota Other than Man.

5-2 5.1.1 Exposure Pathways

)- 2 5.1.2 Radioactivity in the Environment.

5-2 5.2 Radiological Impact on Man 5-3 5.2.1 Exposure Pathways 5-3 5.2.2 Liquid Effluents.

5-4 5.2.3 Airborne Etfluents.

5-4 5.2.4 Direct Radiation.

5-5 5.2.5 Summary of Annual Radiation Doses 5-5 5.3 Etfects of Chemical Discharges 5-5 5.4 Effects of Sanitary and Other Waste Discharges 5-6 5.5 Other Effects.

5-6 5.6 Resources Committed.

5-6 CilAPTER 6 EFFLUENT AND ENVIRONMENTAL blEASUREMENTS AND MONITORING 6-1 PROGRAMS 6.1 Applicant's Preoperational Environmental Programs.

6-2 6.1.1 Surface Waters.

6-3 6.1.2 Ground Water.

6-3 6.1.2.1 Physical and Chemical Parameters 6-3 6.1.2.2 Models 6-4 6.1.3 Air 6-4 6.1.3.1 Meteorology.

6-4 6.1.3.2 Models 6-4 6.1.4 Land.

6-5 6.1.4.1 Geology and Soils.

6-5 6.1.4.2 Land Use and Demographic Surveys 6-5 6.1.4.3 Ecologica1 Parameters.

6-5 6.1.5 Radiological Surveys.

6-5 6.2 Applicant's Proposed Operational Monitoring Programs b-6 11 42 188

TABLE OF CONTENTS (continued)

Page 6.2.1 Rad;ological Monitoring 6-6 6.2.1.1 Mill Effluent Monitartug 6-7 6.2.1.2 Environmental Radiological Monitoring 6-7 6.2.2 Chemical Effluent Monitoring.

6-7 6.2.3 Meteorological Monitoring 6-8 6.2.4 Ecological Monitoring 6-8 5.3 Related Environmental Measurement and Monitoring Programs 6-8 CIIAPTER 7 ENVIRONMENTAL EFFECTS OF ACCIDENTS 7-1 7.1 Mill Accidents Involving Radioactivity 7-1 7.2 Transportation Accidents 7-1 7.3 Other Accidents.

7-2 CliAPTER 8 ECONOMIC AND SOCIAL EFFECTS OF MILL CONSTRUCTION AND OPERATION.

8-1 8.1 Benefit; 8-1 8.2 Costs.

8-2 CHAPTER 's DECOMMISSIONING AND PICLAMATION.

9-1 CHAPTER 10 ALTERNATIVES TO THE PROPOSED ACTION 10-1 CHAPTER 11 BENEFIT-COST ANALYSIS 11-1 CHAPTER 12 ENVIRONMENTAL APPROVALS AND CONSULTATION.

12-1 CHAPTER 13 REFERENCES.

13-1 APPEKDIX A SUGGESTED FORMAT FOR REPORTING RADIOLOGICAL PARAMETERS A-1 iii 142 189

IN"fRODUCTION 1.

National Environmental Goals Prior to the issuance of a license authorizing uranium milling activities, the Nuclear Regulatory Commission (NRC) is required to assess the potential environmental effects of the proposed activities in order to ensure that issuance of the licen3e will be consistent with the national environmental goals.

In order to obtain information essential for this assessment, the Commission requires each applicant for a license to submit a report on the potential environmental impact of the proposed uranium mill and related activities.

The national environmental goals are expressed by the National Environmental Policy Act (NEPA) of 1969 (Public Law 91-190, 83 Stat. 852),

as follows:

a

..it is the continuing' responsibility of the Federal ravernment to use all practicable means, consistent with other essential considerations o f national policy, to improve and coordinate Federal plans, functions, programs, and resources to the end that the Nation may--

"(1) fulfill the responsibilities of each generation as trustee of the environment for succeeding generations;

"(2) assure f or all Americans safe, healthf ul, productive, and esthetically and culturally pleasing surroundings; 4,c 1, 0, 0 tv

"(3) attain the widest range of' beneficial uses of the environment without degradation, risk to health or safety, or other undesirable and unintended consequences;

"(4) preserve important historic, cultural, and natural aspects of our national heritage, and maintain, wherever possible, an environment which supports diversity and variety of individual choice;

"(5) achieve a balance between population and resource use which will permit high standards of living and a wide sharing of life's amenities; and

"(6) enhance the quality of renewable resources and approach the maximum attainable recycling of depletable resources."

In addition to NEPA, the Atomic Energy Act of 1954, and the Energy Reorganization Act of 1974, numerous other pieces of legislation and implementing regulations, both Federal and State, may affect the siting and operation of uranium mills.

Some of these, such as the Endangered Species Act of 1973, require that the NRC make primary determination of acceptability, while compliance with others, such as the Federal Water Pollution Control Act, must be reported to the NRC.

No attempt will be made in this guide to discuss any of these in det. ail.

The applicant should make an independent determination of those statutes and regulations that may affect the proposed mill. Early consul-tation with the staff is encouraged to determine relevancy in specific instances.

47 IQ1 L

i/i v

2.

Applicant's Environmental Reports 10 CFR Part 51, " Licensing and Regulatory Policy and Procedures for Environmental Protection," 651.40, " Environmental Reports," requires that each applicant for a license authorizing uranium milling submit 15 copies of a separate document entitled "The Applicant's Environmental Report" with the license application.

The applicant must retain an additional 85 copies of the environmental report for distribution to Federal, State, and local officials in accordance with written instruc-tions issued by the NRC's Director of the Office of Nuclear Material Sa fety and Saf eguards. The applicant's environmental reports are important documents of public record. Therefore, the applicant is urged to give full atte ntion to their completeness.

The environmental report must discuss the following environmental cons ide ra t i ons :

The environmental impact of the proposed action, a.

b.

Any adverse environmental effects that cannot be avoided should the proposal be implemented, c.

Alternatives to the proposed action, d.

The relationship between local short-term uses of man'n erviron-ment and the maintenance and enhancement of long-term productivity, and e.

Any irreversible and itretrievable commitments of resources that would be involved in the proposed action should it be implemented.

O vi 142 19?

The discussion of alternatives to the proposed action in the environ-mental report must be sufficiently complete to aid the Commission in developing and exploring, pursuant to Section 102(2)(D) of the National Environmental Policy Act, appropriate alternatives.

.in any proposal which involves unresolved conflicts concerning alternative uses of avail-able resources."

The environmental report must also include a benefit-cost analysis that considers and balances the environmental effects of the facility end the alternatives available for reducing or avoiding adverse environmentai effects, as well as the environmental, economic, technical, and other benefits of the facility. The benefit-cost analysis must, to the fullest extent practicable, quantify the various factor; considered.

To the extent that such factors cannot be quantified, they must be discussed in qealitative terms.

The environmental report should contain sufficient data to aid the Commission in its development of ar. independent benefit-cost analysis covering the f actors specified.

The environmental report must further include a discussion of the stat us of compliance of the f acility with applicable environmental quality standards and requirements that have been imposed by Federal, State, and regional agencies having responsibility for environmental protection.

In addition, the environmental impact of the facility should be fully dis-cussed with respect to matters covered by such standards and requirements irrespective of whether a certification from the appropriate authority has been obtained (including, but not limited to, any certification obtained pursuant to Section 401 and any discharge permit obtained pursu-ant to Sect ion 402 of the Federal Water Pollut ion Control Act, as amended).

While compliance with NRC standards and criteria pertaining to radiological effects will be necessary to meet the licensing requirements of the Atomic Energy Act, the benefit-cost analysis for the purposes of the National Environmental Policy Act must consider the radiological effects together with a broad range of ot her environn. ental ef fects of the f acility.

142 193

3.

Preparation o f Envi rotunen_t al Reports Purpose of T_his Guide a.

The Commission's regulatiov in 10 ad Part 51 orovide only general information concerning the content of an applicant's environmental report.

This guide has been prepared to provide specific and detailed guidance for the preparation of environmental reports for uranium mills.

The guide identifies information needed by the NRC staff in its assessment of the potential environmental effects of the proposed uranium mill and di rectly associated mir.ing activities and establishes a format acceptible to the staff for its presentation.

Conformance with this s t.a nd a rd format, however, is not required.

Use of the format of this the completeness of the information provided, will guide will help ensure assist the NRC staff and others in locating the information, and will aid in shorteping the time needed for the review process.

b.

Scope of This Guide In order to cover a wide variety of anticipated situations, the

., cope of this guide is comprehensive In some instances, requests for specific information may not be applicable to a particular mill or site.

If any topics are not relevant to the particular mill under consideration, the applicant should identify them.

If any topics in this guide relate to information not asailable at the time the report is prepared, the applicant should indicate when the information will be available.

c.

Presentation of Information The applicant should strive for clear, concise presentation of the information provided in the environmental report.

Each subject viii I42 194

should be treated in sufficient depth and with sufficient documentationn to permit the Commi n i on to evaluate the extent of the environmental impact independently.

Tables, line drawings, and pho'.ographs should be used wherever they contribute to the clarity and brevity of the report.

The number o f signi ficant figures stated in numerical data should reflect the accuracy of the data.

Descriptive and narrative passages should be brief and concise.

In cases where test results are needed to support conclusions, test data procedures, techniques, and equipment. used to perform tests should be included.

Pertinent published information relating to the site, the mill, and its surroundings should be referenced.

Where published information or assumptions are essential to evaluate specific environmental effects of the proposed activities, they should be included in sumury or verbatim f orm in the environmental report or as an appendix to the report.

Some of the information t.

ae included in the environmental report may have already been prepared by the applicant during preparation of the license application for the proposed mill.

In such cases, this i n f o rma tion (whether in the form of text, tablea. or figures) should be incorporated in the environmental report where appropriate in order to provide a complete document.

The site for the mill mr.y also be the site of the mine The applicant, in preparing the environmental report relating to cuch a mill, should consider the cumulative or synergistic effects of directly asso-ciated mining activities.

  • Documentation as used in this guide means presentation of information, supportic:g data, and statements and includes (1) references to published information, (2) citations f rom the applicant's experience, and (3) reference to unpublished information developed by the applicant or the applicant's consultants. Statements not supported by documentation are acceptable provided the applicant identifies them either as inf ormation f or which documentation is not available or as expressions of belief or judgment.

142 195 t*

B.

STANDARD FORMAT AND CONTENT OF EWIRONMENTAL REPORTS FOR 12ANIUM MILLS 1.

PROPOSED ACTIVITIES This chapter should discuss the proposed project and the activities to be conducted as a result of the project. For example, such matters as are reserves, ore-body locations, anticipated quantity of ore to be mined and milled, mining methods, plans for overburden storage and disposal, cre transport, milling processes, plans for tailings disposal and management, transport of product, operating plans and schedules, expected longevity of the project, U c ntent f the ore, ore processing 38 rate, concentrate yield, planned end use of the project areas, and surety arrangements for the eventual decommissioning of the mill and reclamation of the areas impacted should be addressed.

142 196 1-1

9 2.

THE S _ITE This chapter should present the basic relevant in f ormat ion concerning those physical, iii o l og i ca l, human, and social characteristics of the art a "nvironment that might be af fected by the constsruction arul operation o f a ur anium milling project and its associatil.: t t a t ies in the region.

To the extent possible, the inf onaation preser t ed s?.nld reflect observa-irors and measurements mc.de over periods of time sufficient to allot:

detensible conclusions to be reached.

2.1 Site.ocation and Layout Provide a map showing the site and its location wit h re:> pe t t to State, county, and other political subdivisions. On Jctailed maps, show location of the plant perimeter-exclusion area boundary; applicant's property; adjacent properties, including water bodies. wooded areas, and farms; nearby settlements; industrial plants, parks, and othe public facilities; and t ransport at ion links (railroads, highwavs. watorways).

Indicate total acreage owned or leased by the appli: ant aan thM part occupied or modified by the mine and mill.

Indicate oth( r emisting and proposed uses of applicant's property and the acreage devoted 'o these uses.

Describe any plans for site modifications such as a visitors' center.

A contour map of the site should also be supp1ted with eleva-t ion contours of an interval suttable to show significant variations of the site environs and drainage gra itents.

In addition, indicate i f the flood plain.

This information should be site is in the vicinity of a

supplied as sepa rate maps, if required, for clarity.

2.2 lises o f _A(!j ac ent I.a n d s and Waters I rnt i ca t e, within an 8-km (5-mi) radius, the nature and extent of present and projected land use (e.g, a gr i citl tu re, livestock raising, daicies, pa s t u re l a ruls, residences, wildlife prescrves, sanctuaries, hunting areas, i ndiis t r i es, recreation, transportatlon) and any recent t rernis such as abnormal changes in population or industrial patterns Note whether any ot her nuclear fuel cycle tacilities are located or are proposed wit hin an 80-km (50-mi) radius of t he site Provide in tabular form for each of the 22-1/2-degree sectors centered on one of the 16 compass points, i e.,

north, north northeast, etc., the distances (to a distance of 8 km (5 mi)) irom the center of the tite to the following:

a.

Nearest cattle (or other meat animals) grazing on natural iorage b.

Nearest game animals consumed by sportsman.

c.

Nearest residence.

d.

Nea rest site boundary.

r e

Nearest vegetable garden larger than 50 m' (60 yd') in area.

The type of crop and amounts produced should he noted.

Where possible, the applicant should provide specific information on act ual consumption of the treat f rom cat t le arel game anima ls.

Provide data on annual production and distribution of meat (kg) and truck farming produce (kg) within an 80-km (50-mi) radius from the proposed f acili ty.

Provide information on grazing season (give dates) 2-Z

\\ rtc s<m

and feeding regimes for cattle Agricultural production, crop yield, grazing, and feeding data may be obtained irom sources such as local and State agricultural agencies, agricultural agents, and other reliable sources.

Identify the location, nature, and amounts of present and projected surf ace and ground water use (e.g., water supplies, irrigation, reservoirs, recreation, and t ransportation) within 16 km (10 mi) i.f the site and the present and projected population associated with each use point, where appropriate Data on both present and projected future water use should be sum-marized and tabulated; users should be located on maps of legible scale.

Tabulat tens should include:

a.

Location:

Include symbols shown on maps identifying the loca-t ion of water users Provide map coordinates if appropriate b.

Distance f rom mill.

c Withdrawal Rate Provide present and projected withdrawal rate (in liters per second or cubic meters per second) for each water use d.

Return Rates:

Provide present and projected return rates (in liters per second or cubic met er s per second) if appropriate Type of Water Use Provide type of water use f or each location, e

e. g., municipa l, i ndust rial, i rri gat ion, steck/ game watering.

f.

In addition, for ground-water use, indic at e depth of wella, ground-wa t er eleva t ion, and drawdown and cha racterize t he use by a<pii f er.

} k f_

9

g.

Source and Projection of Water-Use Estimates: Where use rates are anticipated to change over the life of the project and beyond, indicate projections and the source of the projection Information.

Sources for such projections may be available from u s e r:: or planning agencies et dif f erent levels of government.

For items e and d above, if use varies significantly seasonally, indicate monthly values Provide data on the annual recreational and commercial fish catch from waters within an 8-km (5-mi) radius of the sitt Report tbc catch by principal species, location, and amount used for human consumption (note amounts consumed locally).

2.3 P_opulation Distribution Population data presented should be based on the most recent census data.

On a map of suitable scale that identities places of significant population grouping, such as cities and towns, within an 80-km (50-mi) radius, concentric circles should be drawn with the mill at the center potat, at distant" ot 2,

10, 20, 30, 50, 70, and 80 kilometers. The circles should be divided into 22-1/2-degree sectors with each sector centered on one of t i.e lei compass points (with reference to true north, i.e.,

no r t h-no r t hea s t, northeast. etc.).

A table appropriate.y keyed to the map should provide the current residential population within each area for the expected first year of mill operation and census years through the anticipated life of the mill.

The tables should provide sepnate and cumulative population totals for each se tor an1 annular ring. Distant e to the nearest residence should be noted f or each sector.

The basis for population projections should be described.

Descriptive miterial should include tables giving significant populat ion and vis t t or st atistics of neighboring schools, plant s, hospi tals,

k

(

9-sports facilities, residential areas, parks, etc., within 8 km (5 mi) of t he plant.

2.4 Regional llistoric, Archeological; Architectural

Scenic, u

Cu_Itural, and Natural Landmarks Areas valued for their historic, archeolcgical, architectural, scenic, cultural, or natural significance may be affected. The environ-meatal report should include a brief discussion of the historic, scenic, archeological, archimectural, cultural, and natural significance, if any, of the mill site and nearby areas with specific attention to the sites and areas listed in the National Registry of Natural Landmarks and properties included in on eligible for inclusion in the National Register of Ilistoric Places.

The National Registry of Natural Landmarks appears in 37 FR 1496.

The National Register of Historic Places is published annually in the Federal Register; additions are published in the Federal Register on the first Tuesday o.

each month.

General guidance on the treatment of historic, archeological, architectural, and cultural features can be obtained from the National Park Service publication, " Preparation of Envi ronmental Sta tements : Guidelines for Discussion of Cultural (Ilistoric, Archeologi cal, Architectural) Resources," August 1973.

The env i ro.,ue n t a l report should identify those properties included in or eligibl_ for inclusion in the National Register of Ilistoric Places located within the area of the project's potential environmental impact.

Also, the a; plicaat should discuss its consultation with the appropriate State lii s t o r i c Preservation Officer concerning the identification of properties included

r eligible for inclusion in the National Register y

Copies may c e,btai -d f rom Chie f IIistorian, Room 1226, National Park Service, '8t h and C St reets, N.W., Washington, D.C.

20240.

2-5 142 201

of lit storic Places. The environment _1 report should contain evidence of contact with the lli s t o r ic Preservation Gitater for the State involved, including a copy of h.s comments tuncerning the ef fect of the undertaking on historic, a rcheological, a rchitectural, and cultural resources.

State whether new roads, pipelines, and utilities connected wi'.h the proposed mill will pass through or near any area or locatien of known historic, scenic, cultural, natural, archeological, or architect ural significance 2.5 Geology Describe the major geological aspects of the site and its environs.

The discussion should note the stratigraphy, structure, and tectonic history.

Comment on regional continuity, faulting, dip, and strikes of water-bearing formations that will be affected. An inventory of econom-ically important minerals and energy-related deposits, in addition to t he uranium ore, should be included. Any unique mineralogical or paleonto-logical deposits of particular scientif ic interest should also be noted.

Any effect that planned operations might have on the future availability of other mineral resources should be noted.

Detailed geological data at building sites and in the vicinity of tailings or other effluent impoundments, sanitary landfills, spoil disposal areas, and sewage disposal facilities should be included.

These data should include st rike and dip and lateral and vertical distribu-tion of permeable layers, shales, and clays, and data on any fault, fracture, or joint pattern that may exist.

Locations of local outcrops where seepage from landfills, damps, impoundments, and sewage facilities is likely to occur should be noted.

The location of ground water with respect to tailings disposal areas, spoil dumps, liquid impoundments, sanitary landfills, and sewage 2-6

")

') G )

14L (GL

disposal facilities is important f or the assessment of possible ground-water cont amination. The discussion should include a statement concerning permeability and porosity) of the the hydraulic properties (such as materials between the ground water and the above f acilities.

2.6 Seismology Discuss the seismicity (including history) of the region.

Where possible, associate seismic events with tectonic features identified in regional earthquake epicenter map the geology discussion.

i'u r n i s h a showing si te location.

2.7 Hydrology The effects of mine/ mill construction and operation on adjacent surface and ground waters are of prime importance The applicant should describe, in quantitative terms, the physical, chemical, biological, radiological and hydrological characteristics, the typical seasonal ranges and averages, and the historical extremes for surface and ground water bodies.

Information relating to water quality characteristics should include maasurements made on or in close proximity to the site.

Information should be presented in sufficient detail to allow an independent review to be made of the ef fects of construction and operation on both resources. Data should be presented in metric units as specified by the U.S. Geological Survey.

2.7.1 Ground Water Describe the hydrology of the ' region that a f fects the local ground-water aquifers, forma t ions, sources, and sinks. Describe the recharge potential o f t he i.wedia te plant a rea, including vertical and horizontal permeabilities o.' the natural and modified terrain, as well as that of tailing disposal 142 203 2-7

areas.

Indicate gradients and sea onal variations in ground-water levels ben"ath the site.

Furnish sufficient site-specific data for the evaluation of the effects of construction and operation of the facility on established ground-water tab'es and usage. This is especially important for consideration of dewatering o. erations in associated mines.

Descriptions of the major a uifers in the area should include piezometric contour maps, hydraulic gradients, permeabilities for reprc-sentative geologic features, total and ef fective porosities, bulk density estimates, storage coefficients, dispersion and distribution (sorption) coefficients, descriptions of pertinent geologic formations and soil types, including formation depth throughout the site and to the nearest downgradient well or water body, chemical and radiological properties, and time histor f es of ground-water fluctuations.

The applicant should provide data concerning any drawdown of ground water that may be caused by withdrawals f rom neighboring major industrial, agricultural, or municipal wells.

2.7.2 Surface Water Describe the location, size, shape, and other hydrologic character-istics of water bodies in the environs of the site.

Include a description of upstream and downstream river control topographic map showing the major hydrologic structures, and provide a

teatures.

2.8 Meteorology description of the meteorological This section should provide a

diffusion characteristics of the site and its surrounding area.

The description should include the use of data collected for at least one

\\k}

annual cycle trom an onsite or nearby local meteorological station, plus examination of additional regional meteorological information. Sufficient data should be included to permit independent evaluations and assessmeuts of atmospheric dif fusion characteristics.

The following data concerning site meteorology from meteorological measurements taken onsite and at nearby representat ive stations should be presented; a.

Quarterly ano annual wind rose presentation for the 16 compass directions.

b.

Quarterly and annual wind speed, wind direction, and atmospheric stability data in joint frequency form at heighto apresentative of effluent releases.

c.

Total precipitation and evaporat ion by month.

This information should be fully documented and substantiated as to validity of its representation of ext.ected long-term conditions at and near the site.

Present the joint wind speed-stability-di rection frequencies (in item b above) in tabular form, giving the frequencies as f ractions when using 5 -yea r flational Weather Service summaries or as number of occur-r e n c e :, when using only 1 or 2 years of onsite data.

The data should be presented for each of the 16 compass directions, and the stability cate-gories should be established to conf orm as closely as possible with those of Pasquill.

In addition, the annual average inverston height should be provided f rom ot her nearby weather stat ions

'>_9 142 205

Guidatae on acceptable onsite metcotological measurements and data format is presented in Regulatory Guide 1.21 "< >ns i t e Meteorological Programs "

a discussion of general In addition, this section should provid-clinatology, existing levels of att pollution and their effects on site operations, the relationship of the meteorological data gathered on a regional basis to local data, the impact of the local terrain and large lakes and other bodies of water on meteorologn al conditions in the area and the occurrence of severe weather in the irea and its elfects. Data on diurnal and monthly averages and extremes of temperature and humidity

hould also be provided.

2.9 Ecology In this section, the applicant should describe the flora and fauna in the vicinity of the site, their habitats, and their distribution.

This initial inventory will reveal certain organisms which, because of their importance to the c onunun i t y, should be given :;peci t ic at t ent ion.

A species is "important" (f ar t he purposes of this guide) if a speciftc causal link can be identified between the facility and the species and if one or more of the following criteria applies (a) the species it comme rc ia l ly o r recreationally valuable, (b) the species is threatened or endangered,- (c) the species affects the well-being of some important species within criteria (a) or (b), or (d) the species is critical to the structure and function of the ecological system or is a biological indicator of radionuclides or chemical pollutants in the envi ronment.

In the writing an reviewing of envi ronmental repo rt s, speci f ic cons idera-l tion should be given to possible impact on any species (or its habitat )

that has been determined to be endangered or threatened with endangerment by the Secretary of the In t e r i o r and t he acc ret a ry o f Comme rce New terminology de t ining " endangered o r t hreat ened wi th endange rment" has been promulgat ed in Public 1.aw 4 3-205, 8 7 S t a t. 884.

0 2-10 142 206

The initial inventory should establish the identity of the majority of terrest rial and aquatic organisms on or near the site and their rela-tive (qualitat ive) abundances. The applicant should identify the "important' species f rom this list and discuss in detail their quantitat ive abundances.

The discussion should include species that migrate through the area or use it for breeding grounds Special attention should be given to the relative importance of the site area to the total regional area of the living resources (potential or exploited).

The applicant should provide data on the count and distribution of important domestic fauna, in particular, cattle, sheep, and other meat animals that may be involved in the exposure of man to radionuclides.

Important game animals should receive similar treatment.

A map that shows the distribution of the principal plant communities should be provided.

The discussion of species-environment relationships should include descriptions of area usage (e.g., habitat, breeding, etc.) for important species; it should include life histories of important regional animals and aquatic organisms, their normal seasonal population fluctuations, and their habitat requirements; and it should include identification of food chains and other interspecies relationships, particularly when contributory to predictions or evaluations of the impact of these are the f acility on the regional biota.

Identity any definable preexisting environmental stresses from per'iient ecological conditions pollutants, as welI as sources such as suggestive 01 such, tresses lhe status of ecological succession should be described.

Discuss the histories of.iny intestations, epidemics, or catast rophe: (caused by natural phenomena) that have had a significant impact on regional biota.

-11 142 207

The information should be presented in two separate subsections:

" Terrestrial Ecology" and " Aquatic Ecology." The sources of information should be identified. As part of this identification, present a list of pertinent published material dealing with the ecology of the region.

I.ocate and describe any ecological or biological studies of the site or its environs currently in progress.

2.10 Background Radiological Cha racteristics Regional radiological data should be reported, including both natural background radiation levels and results of measuren ents of concentrations of radioactive materials occurring in important biota, in soil and rocks, in air, and in regional surf ace and local grota.d waters.

These data, whether determined during the applicant's preoperational surveillance program (see Section 6.1.5) or obtained from other tources, should be referenced.

2.11 Background Nonradiological Characterir. tics Regional nonradiological characteristics, particularly those that are similar to expected site-related effluents, should be reported.

Data should include such parameters as heavy metals and other potentially toxic substances, atmospheric pollutants, dusts, etc., that could affect water or air quality.

Other regional sources of these same materia ls should be noted along with a discussion of the possible contribution to levels f ound at the f acility site.

2.12 Other Environmental Features For certain sites, some relevant informatu n on tFy mill or mine environs may not clearly fall within the scope of the preceding topics.

Additional information may be required with respect to some environmental features in order to reflect the value of the site and site environs to important segments of the population. Such inf ormation should be included here O

2-]?

142 208

3.

THE MILL AND filNE(S)

The operating will and associated mines should be described in this chapter.

Since environmental effects ire of primary concern for this report, the combined effects of mill and mine effluents and

'ated systems that interact with the environment should be described in detail sufficient for the reviewer to independently reach def ensible conclusions.

3.1 Site! Area A map o.

the site area should be included; it should clearly show the following:

The location of the site boundary.

a.

b.

The location and orientation of principal structures within the site area.

Principal structures should be identified as to function (e.g.,

mines, ore crushing structures, chemical separation and ctorage, ore stock piles, waste rock dumps, tailings disposal areas, retention and settling ponds, explosive magazines, housing areas, administration buildings, yellowcake storage a reas, pa rking lots).

c.

The boundary 1ines of any restricted areas, access to which a re to be cont rolled by fences or othe-means.

d.

A scale that will permit the measurement of distances with reasonable accuracy.

e True north.

-. Site means the contiguous real estate on which the mine and mill are located.

142 209 3-'

3.2 External Appearance of rti l l The building layout and plant profile m>uld be shown to scale by line drawings or other illustrative te(hniques The architectural design and efforts to make the st ruct ures n.1 grounds esthetically pleasing should be noted.

3.3 flill Circuit The entire mill process and/or circuit should be quantitatively and qualitatively described in sufficient depth to permit confirmation af the quantities and constituents of all gaseous, liquid, and solid wastes and ef fluents generated in the process. The followin>; should be included:

A flow diagram of the process and/or circut t.

a.

b.

A material balance diagram.

Description of any water recycle systems.

c.

d.

Water balance diagram for the entire mining / milling project.

3.4 Sources of. Mill Wastes and Effluents Clearly identify the location of release points for all gaseous (include stack heights), liquid, and solid wastes and ef fluents (including bulk storage locations, i.e.,

piles of ore or tailings, overburden dumps, etc. ) speci fying quantities, concentrations, and physical, chemical, and radiological characteristics of all materials released. Average and maximum release rates should be included plus all pertinent supporting information such as assumptions and computational methods used.

The quantities and concentrations of radioactive and nonradioactive materials

}k2 2i

that will be released into the environs should be compared wit h State and other applicable standards.

Suggested fortats for supplying this material on radioactive emissions are included as Appendix A of this Guide.

The tables supplied by the applicant should not be 21.nited to the examples listed, however.

3.5 Controls of Mill Wastes and Effluents Provide a description of mill waste and effluent control systems and equipment for minimizing to as low as is reasonably achievable the quantities of materials released into the environment.

Identify the operating ef ficiency of such systems and equipment in relation to current best methods for controlling milling wastes and effluents.

Also, identify the factors that affect these efficiencies, and describe the operating practices to be pursued during the life of the proposed project.

For waste retentionshtems, a design analysis of the integrity of the proposed systems should be provided. This should include:

a.

Drawings showing the layout in plan, typical cross sections of all embankments showing proposed design and, if applicable, anticipated future extensions, and other pertinent design details.

Embankment designs should include information on heights, top width, side slopes, freeboard, seepage control, and protection of embankment surfaces as well as foundation design.

b.

The results of soil tests, geologic exploration, foundation materials stability investigations, as well as characteristics of fill material and a description of the construction methods and specifications.

142 211 3-3

3.o Sanitary and Other Mill Waste Systems Describe any other nonradioactive solid or liquid waste materials, such as sanitary, laundry, and chemical laboratory wastes that may be generated during operation.

Describe the manner in which they will be treated and controlled, and describe procedures for disposal.

Means for control and treatment of all systems subject to effluent limitation guidelines and standards of performance under the Federal Water Pollution Control Act (FWPCA) should be described.

The applicant should (a) describe any other airborne effluents (e.g., from diesel engines, gas turbines, heating plants, incinerators) created during project operation, (b) estimate the frequency of release and describe how they will be treated before release to the environment, and (c) estimate the total quantity of pollutants to be discharged annually.

3.7 Mining Activit.ies This portion of the report should contain a thorough description of the interrelated minir.g activities including:

Topographical maps showing locations and areas to be mined and a.

haulage and access roads.

b.

A description of the mining metFa1(s) to be employed including any dewatering activities and assuciated ef fluents.

A description of the method (s) for accumulating and storing c.

wastes in order to minimize esthetic and other ef f ects.

\\ h, 212 Q

a

d.

Identification and source terms of all sources of effluents associated with mining activities (radon and particulate emissions, dust from haulage, storage activities, etc.),

including release rates and concentrations and their physical and chemical characterist ics.

\\

e.

A description of methods to minimize and control releases of effluents into the environe.

f.

Any other information that mignt be helpful in assessing the environmental ef fects connected with the mining project.

}NLA ') 3

(-

3-5

4.

ENVIRONMENTAL EFFECTS OF SITE PREPARATION, MILL CONSTRUCTION, AND MINE OPEN _ING The construction of a uranium mill and the openings of related mines will inevitably affect the environment; some of the effects will be adverse and some may be beneficial.

Effects are considered adverse if environmental change or stress causes a valuable or otherwise important biotic population or natural resource to be less safe, less healthy, less abundant, less productive, less esthetically or culturally pleasing; if the change or stress reduces the diversity and variety of individual choice, the standard of living, or the extent of sharing of life's amenities; or if the change or stress tends to lower the quality of renewable resources or to impair the recycling of depletable resources.

In the applicant's discussion of adverse environmental effects, it should be made clear which of these are considered unavoidable and subject to later amelioration and which are regarded as unavoidable and irreversible.

Those effects that represent an irretrievable commitment of resources should receive detailed consideration in Section 4.2.

(In the context of this discussion, " irretrievable commitment of resources" alludes to natural resources and means a permanent impairment of these, e.g.,

loss of wildlife habitat; destruction of nesting, breeding, or nursing areas; interference with migratory routes; loss of valuable or esthetically treasured natural areas; and expenditure of directly utilized resources.)

4.1 Site Preparation and Construction The applicant should organize the discussion in terms of the ef fects of site prepacation (including mine opening) and mill construction on 142 214 4-1

both land use and water use. The applicant should consider causequences to both human and wildlife populations and indicate which are ur. avoidable, irreversible, etc., according to the categorization set forth earlier in this chapter.

In the land-use discussion, describe how construction activities may disturb the existing terrain and wildlife habitats.

Consider the effects of such activities as creating building material supply areas; build.ag temporary or permanent roads, bridges, or service lines; disposing of trash; excavating; and land filling. Provide information bearing on such questions as how much land will be torn up, for how long, will there be dust or smoke problems, what explosives will be used, where and how of ten.

Indicate proximity of human populations and identify undesirable impacts on their environment arising from noise, disruption of stock grazing patterns, inconvenience due to the movement of men, material, machines, including activities associated with any provision of housing, transportation, and educational facilities for workers and their f amilies.

Describe any expected change:, in accessibility of historical ar.d archeo-logical sites in the region.

Discuss measures designed to mitigate or reverse undesirable ef fects, such as erosion control, dust stabilization, landscape restoration, control of truck traffic, and re s to ra t i o n of a f fected habitats.

The discussion should also include any etfects of site preparation and onstruction activities whose consequences may be beneticial to the re t;i o n.

The discussion of water use should describe the impact of site preparation and construction activities on area water sources.

Such activities would include mine dewatering, diversion of streams, placement of fill material in water, etc.

The applicant should describe the ef fects of these act ivities on t ish and wildlif e resources, water quality, 4-2 A ')

71F 4L

l. I d

water supply, esthetics, etc., as applicable. Describe measures to miti-gate undesirable ef fects such as pollution control and other procedures for habitat improvement.

4.2 Resources Committed Discuss any irreversible and irretrievable commitments of resources (loss of land, destruction of biota, etc.) that are expected should site preparation and mine opening and mill construction proceed. Such losses should be evaluated in terms of their relative and long-term net impacts, as well as their absolute impacts.

(See Section 5.6 of this guide for more detailed consideration. )

142 216 4-3

5.

ENVIRONMENTAL EFFECTS OF MILL AND MINE OPERATION This chapter describes the interaction of the mill and mine (discussed in Chapter 3) and the environment (discussed in Chapter 2).

To the extent possible, material presented in Chapters 2 and 3 does not need to be repeated. Measures planned to reduce any undesirable effects of the tot al project on the environment should be described in detail.

In the discussion of environmental ef f ects, as in Chapter 4, ef f ects that are considered unavoidable but either inherently temporary or subject to later amelioration should be clearly distinguished from those regarded as unavoidable and irreversible. Those effects that represent an irret rievable commitment of resources should receive detailed considera-tion in Section 5.6.

The ispacts of operation of the proposed activity should be, to the fullent extent practicable, quantified and systematically presented.

In the discussion of each impact, the applicant should make clear whether the supporting evidence is based on theoretical, laboratory, onsite, or field st udies undertaken on this or on previous occasions. The source of eacb impact (the plant subsystem, waste effluent) and the population or res urce affected should be made clear in each case.

The impacts should be distinguished in terms of their effects on surface water bodies, ground water, air, land, land use, acolegical systems, and important plants and ani.nals.

Finally, the applicant should discuss the relationship hetween local s ho r t -t e rm us<s of man's environment and the maintenance and enhancement of long-term productivity.

As used in this guide, "short term" reters to the operating 1ife of the proposed faciIity and "long 142 217 s-i

term" refers to time periods extending beyond this life. The applicant should assess the action for cumulative and projected long-term ef fects from the point of view that each generation is trustee of the environment for each succeeding generation.

5.1 Radiological Impact on Biota Other Than 'ian In this section the applicant should consider the impact on biota other than man attributable to the release of radioactive materials from the facility. The biota to be considered are those species of local flora and local and migratory f auna defined as "impc-tant" in Section ~ 9 Since the region may contain many important species, the applicar.

should concentrate any efforts on those important species whose terrestrial t ad aquatic habitat ; provide the highest potential for radiation exposure.

5.1.1 Exposure Pathways The various possible pathways for radiation exposure of the important local flora and local and migratory fauna should be identified and described in textual and flow-chart format. The pathways should include the important routes of radionuclide translocation (including food chains leadirg to important species) to organisms or sites.

5.1.2 dadioactivity in the Environment In Sections 3.4 and 3.7, the radionuclide and chemical concentrati ens in the liquid and gaseous effluents discharged from the site are listed.

In this section, the applicant should consider how these effluents are quantitatively distributed in the environment. Specifically, estimates should be provided for the radionuclide concentration (a) in any water sources, (b) on land areas, and (c) on vegetation (on a per unit area basis) in the environs.

5-2 142 218

If there are other components of the physical environment that may becoca contaminated and thus result in the exposure of living organisms to radiation, they should be identified and their radioactivity burden estimated.

In addition, information concerning any cumulative buildup of radionuclides in the environment should be presented and discussed.

A summary of data, assumptions, and models used in determining radioactivity concentrations and burdens should be provided.

From considerations of the exposure pathways and the distribution of radioactivity released into the environs, the applicant should estimate the maximum radionuclide concentrations that may be present in important local flora and local and migratory fauna. Values of bioaccumulation factors used in preparing the estimates should be based on site-specific data if available; o the rwi s e, values from the literature may be used.

The applicant should tabulate and reference the values of bioaccumulation factors used in the calculations.

5.2 Radiological Impact on Man in this section the applicant should consider the radiological effects of oparationa and transportation of radioactive materials on man.

Estimates of the radiological impact on man via various exposure pathways should be provided.

5.2.1 Exposure Fathways The various possible pathways for radiation exposure of man should be identified and described in textual and flow chart format.

Discuss any exposure pathways, if they exist, involving radionuclide accumulation in specific components of the environment.

} k [_

5-3

5.2.2 I.iquid Effluents E..timate the expected annual average concentrations of radioactive nuclides (listed in Sections 3.4 and 3.7) in receiving water at locations where water is consumed or otherwise used by human beings or where it is inhabited by biota of significance to human food chains.

Specify the dilution factors used in preparing the estimates and the locations where the dilution factors are applicable Consideration should be given to the absence of mixing and dilution because of f act ors such as channeling.

Determine the expected radionuclide concentrations in aquatic and terrestrial organisms significant to human food chains. Use the bioaccumu-lation f actors given in Section 5.1.2 or supply others as necessary.

Using the above information and any other necessary supporting data, calculate the total annual body and significant organ doses (millirems) to individuals in the population (discussed in Section 2.3) from all receiving-water-related exposure pathways, i.e.,

all sources of internal and external exposure.

Provide, as an appendix, details of the models and assumptions used in these calculations.

5.2.3 Airborne Effluents From release rates of airborne radioactivity and meteorological data (Sections 3.4, 3.7, and 2.8), estimate total annual body and signif-icant organ doses (mi l l i rems ) to individuals exposed at the point of maximum ground-level contentrations off site, individuals exposed at the site boundary in the direction of the prevailing wind, individuals exposed at the site boundary nearest to the sources of emission, and individuals exposed at the nearest residence in the direction of prevailing wind. Assume annual average meteorological conditions. Identif y locations of points of release (e.g., stack, roof vent) used in calculations.

Aq q q 1^

OL ll 5-4

Estimate deposition of radioactive materials on food crops and pasture grass. Estimate total annual body doses (millirems) and significant annual doses received by othet organs via such potential pathways.

Provide an appendix describing the.nodels used in these calculations.

5.2.4 Direct Radiation The applicant should provide an estimate of the maximum annual external dose (millirems) that would be received by an individual at the nearest site boundary f rom direct radiation. Provide an appendix describing the models and assumptions used in these calculations.

5.2.5 Summary of Annual Radiation Doses The applicant should provide estimates of the maximum annual doses (millirems) to an individual at the site boundary and the nearest residence

. hat could be received via all pathways.

The applicant should also present a table that summarizes the estimated radiation dose to the regional population (within 80-km) from mill-and mine-relited sources using values calculated in previous sections.

The tabula; ion should include (a) the total annual doses (man-rems) to the population (discussed in Section 2.3) f rem all receiving-water-related pathways and (b) the total annual doses (man-rems) to the population attributable to airborne ef fluents.

5.3 Effects of Chemical Discharges In this section, the specific concentrations of nonradioactive wastes in effluents at the points of discharge should be compared with natural ambient concentrations without the discharge and also compared with applicable standards.

The projected effects of the effluents for 5-5 142 221

both acute and chronic exposure of the biota (including any long-term buildup in soils and sediments and in the tnota) shoulit be iilent i fied and discussed.

Dilution and mixing of disch<irges into the receiving environs should be discussed in de t a i 1, a nd es t in.a t e:, of concentrations at various d i s t. int es from the point of discharge should be provided.

The effects on terreatrial and aquatic environments from chemical wastes that contaminate ground water should be included.

5.4 Effects of Sa n i t a ry a nd O t he r_ _Wa_s t e l_h s el_ia rge s Describe and discuss the environmental impact associated with sanitary and other mill waste systems discussed in Section 3.6.

5.5 Other Effects The applicant should discuss any effects of operation that do not clearly fall under any single topic of Sections 5.1 through 5.4.

These may include changes in land and water use at the pr3 ject site, interac-tion of the f acility with other existing or projected neighboring f acilities, effect of ground-water withdrawal on ground-water resources in the vicinity of the mine and mill, effects of construction and operation of roads, transmission corridors, railroads, ete, effects of changes in surface water availah lity on biotic populations, and disposal of solid and liquid wastes ot n r than t ruc e al ready discussed.

5.6 I<esources committed Any ir:eversible and irretrievabic commitments of resources due to mine and mill operation should be discussed. This discussion should include both direct commitments such as depletion of aranium resources and irreversible environmentel losses such as destruction of wildlife habitat.

\\L 9_g

In this discussion, the applicant should consider lost resources f rom the viewpoints of both relative impacts and long-term net effects.

As an example of relative impact assessment, the loss of a few animals of a given species could represent quite dif ferent degrees of significance, depending on the total population in the immediate region. Such a loss in the case of a small local population, however, could be less serious if the same species were abundant in neighboring regions.

Similarly, the loss of a given area of highly desirable land should be evaluated in terms of the total amount of such land in the environs. These relative assessments should accordingly include statements expressed in percentage terns in which the amount of expected resource loss is related to the total resource in the immediate region and in which the total in the immediate region is related to that in surrounding regions. The latter should be specified in terms of areas and distances f rom the site 9

142 223 m

6.

EFFLUENT AND ENVIRONMENTAL MEASUREMENTS AND M0hlTORING PROGRAMS The purpose of this chapter is to describe in detail the means by wnich the applicant collected the baseline data presented in other chapters and to describe the applicant's plans and programs for monitor-ing the impacts of the proposed activities on the environment.

Section 6.1 is addressed to the measurement of preexisting character-istics of the site and the surrounding region. This program will estab-lish a reference framework for assessing subsequent environmental effects attributable to the proposed activity and for use as baseline reference data at the time of site decommissioning.

The applicant's attention is directed to two considerations pertinent to Secticn 6.1.

First, the term " preexisting" refers to the characteristics of the site prior to any mining-related activities. A gisen characteristic 9

or parameter may or may not require assessment prior to site disturbance and mill construction, depending on whether that particular characteristic may be altered at these stages.

Second, in most instances this guide indicates the specific environmental ef fects to be evaluated; consequently, the parameters to be measured will be apparent.

In some cases, it may be necessary to establish a monitoring program based on the applicant's own identification of potential or possible

!ects and to provide the underlying rationale for such a program.

At t

y, the applicant

~

shoeld caref ully review the plans for measurement o. preexisting conditions to ensure that these ple include all factors that must be subsequently monitored as discussed in Section 6.2.

6-1

Sampling design, frequency, methodology (including calibration and checks with standards), and instrumentation for both collection and analysis should be discussed as applicable.

In all cases, the applicant should estimate the statistical validity of any proposed sampling program.

Information should be provided on instrument

curacy, sensitivity, and (especially for highly automated systems) reliability.

Where standard analytical or sampling techniques can be identified, they need only be so identified anc ref erenced.

For quantitative descriptions of samples collected within each area of interest and each time of interest, descriptive statistics should include, unless justifiably omitted, the mean, standard deviation, standard error, and a confidente interval for the meae In each case, the sample size should be clearly indicated.

If diversity indices are used to oescribe a collection of organisms, the specific diversity indices used shoald be stated.

O 6.1 Applicant's Preol.crational Favironmental Programs The programs for collection of initial or baseline environmental data prior to submittal of the license application should be described in sufficient detail to make it clear that the applicant has established thorough and comprehensive approach to environmental assessment. The a

description of these programs should be confined principally to technical desc ript ions of inst rumentat ion, scheduling, technique, and procedures.

Where it.f ormat ion f rom the literature has been used by the applicant, it should be concisely summa ri zed and document ed by re f e rence t o o ri gi na l data sources.

Where the availability of original sources that support important conclusions i: limited, the applicant should provide either u-2 142 225

extensive quotations or references to accessible secondary sources. - In all cases, information derived from published results should be clearly distinguished from information derived from the applicant's field measurements.

6.1.1 Surface Waters If a body of surface water n.y 1.e af fected by the proposed activi-ties, the applicant should sc -ibe the programs by which the background condition of the water and th..

related eco:agy were determined.

If a natural water body has already bec.. subjected to enviro'amental stress from pollutant source',

.ter-f this stress and its consequences should be evaluated. The appli ar*.

.cuid t tim '- the potenti al. quality of the af fected water body.

6.1.2 Ground Water In those cases in which the proposed activities may potentially affect local ground water, the program leading to assessment of potential effects should be described.

6.1.2.1 Physical and Chemical Parameten.

The properties and configuration of the local aquifer will have been defined in sufficient reasonable projection of effects of detail (in Section 2.7) to permit a proposed activities on the ground water. Methods for obtaining information on ground-water levels and ground-water quality should be described.

Any reports of work (e.g., ecological surveys) supported by the applicant that are of significant value in assessing the environmeatal impact of the f acility should be included as appendices or supplements to the environ-mental report unless these reports are otherwise generally available.

'~3 142 226

6.1.2.2 Models Models may be used to predict such effects as changes in ground-water levels, dispersion of contaminants, and eventual transport through aquifers to surface water bodies.

The models should be described and supporting evidence for their reliability and validity presenter 6.1.3 Air The applicant should describe the program for obtaining information on local air quality and local and regional meteorology.

6._1. 3.1 Meteorology.

The applicant should identify sources of meteorological data used in the atmospheric transport models and reported in Section 2.8.

Locations and elevations of observation stations, instrumentation, and f requency and duration of measurements should be specified both for the applicant's meas.. ing activities and f or activities of governmental agencies or other organizations on whose information the applicant intends to rely.

Guidance for an acceptable meteorological measurement program and for data format is presented in Regulatory Guide 1.23 (Safety Guide 23), "Onsite Meteorological Programs."

The description should show the basis for predicting such effects as the dispersion of airborne effluents and should present tiie methodology for gathering baseline data.

6.1.3.2 Models.

Any models used by the applicant, either to derive estimates of basic meteorological information or to estimate the effects of effluents, should be described in detail and their validity and accuracy discussed.

Staff guidance should be sought in adapting provided in Regulatory Guide 1.111, " Methods existing guidance such as f or Estimating Atmospheric Transport and Dispersion for Gaseous Ef fluents in Routine Releases trom Light-Water-Cooled Reactors," to the particular effluents f rom uranium mines and milIs.

6-4 142 227

O 6.1.4 Land Data collection and evaluation programs concerning the terrestrial environment.af the proposed mill should be described and justified with regard to both scope and methodology.

6.1.4.1 Geology and Soils.

Those geological and soil studies designed to determine the environmental impact of the construction or operation of the mine/ mill should be described. The description should include identification of the sampling pattern and the justitication for its selection, the sampling method, holding periods, preanalysis treatment, and analytic techniques. Other geological and soil studies (e.g.,

those conducted in support of safety analyses) should be briefly summarized and reference made to the relevant reports for a more detailed presentation.

6.1.4.2 Land Use and Demographic Surveys.

The applicant should describe its program for identifying the actual land use in the site environs and for acquiring demographic data for the region as reported in Section 2.3.

Sources of information should be identified. Methods used to fore-cast probable changes in land use and demographic trends should be described.

6_.1.4.3 Ecological Parameters.

In this section, the applicant should discuss the program used to assess the ecological characteristics of the site, with primary reference to important biota identified in Section 2.9.

6.1.5 Radiologica1 Surveys This section of the environmental report should discuss the methods used to determine the preoperational radiation levels at the site and 6-5 142 228

environs and the concentrations of radionuelides in important local and regional biota, soil, sediment, vegetation, air, and surface and ground waters.

The NRC licensing staff has developed a Technical Position entitled "Preoperational Radiological Environmental Monitoring Programs for Uranium Mills."*

This Technical Position specifies the essential program elements of an acceptable preoperational radiological monitoring program.

6.2 Applicant's Proposed Operational Monitoring Programs The applicant should present the proposed operational monitoring program for planned operations.

Review of this description will be facilitated if the applicant includes maps of proposed observation sites and tabular presentation of summary descriptors of such factors as sample collection and analysis frequency, type of sampling, method of collection, analytic method, preanalysis treatment, instrumentation, and minimum sensitivities.

The discussion should include the justification for the choice of sampling sites, analyses, and sampling frequencies.

The program description should be explicit with respect to the paramete-limits that are not to be exceedei under normal operating conditions and with regard to the actions planned in the event the limits are exceeded.

6.2.1 Radiological Monitoring:

The applicant's operational nonitoring program for radiological ef fects should be described bath for the mine and mill ef f luent-monitoring program and for the environmental monitoring program.

.-Copies may be obtained upon request to the Of f ic e of Nuclear Material Sa fety and Sa f egua rds, U.S. Nuclear Regulatory Commiss ion, Washington, D.C. 20555, Attention: Chief, Fuel Processing and Fabrication Branch.

Regulatory Guide 4.14, " Measuring, Evaluating, and Report ing Radioactivi ty in Releases of Radioactive Materials in Liquid and Airborne Ef fluents f rom Uranium Mills," should be reviewed in connection with this section.

6-6 142 229

6.2.1.1 Mill _ Effluent Monitoring. Describe the proposed effluent-monitoring program for liquid and airborne effluents.

Discuss the sensitivit.y limits for detecting radioactivity corresponding to routinely expected release rates.

List the effluent streams, if any, that will not be monitored and provide a brief rationale for the absence of monitor-ing.

Also, provide criteria for setting threshold levels for corrective action and describe the actions to be taken if these levels are exceeded.

6.2.1.2 Environmental Radiological Monitoring.

The operational monitoring program should be described in detail, with specific attention given to the types of samples to be collected, sampling locations and frequency, the analyses to be performed on each sample, the analytical sensitivity (detection threshold) for each analysis, and the criteria for investigating it reases of con entration of material detected in the environs.

6.2.2 Chemical Effluent Monitoring The proposed measurement program, including instrumentation, locations,

frequencies, and analytical techniques, should be fully described. The description of the program should include instrumentation sensitivity and reliability.

Monitoring procedures prescribed by local, State, or Federal agencies as conditions placed on operation should be so identified.

The criteria for setting threshold levels for corrective action should be presented.

In the case of prescribed quantitative standards set by agencies, the applicable agulation should be cited.

In the case of quantitative limits set by t.m applicant to conform to qualitative standards or restrictions, the ar plicant's rationale should be presented.

i f measurements exceed thresholds, the action to be taken In either case, should be specified.

6-7 142 230

6.2.3 Meteorological Monitoring Tiu-applicant program for mon i t :> r i ng meteorological phenomena should be described.

6.2.4 Ecological Monitoring In the preoperational surveillance p rog ra m, the ao 1, cant will have established methodology for determining the ecological characteristics of the region. The applicant should desc ribe any additional ecological monitoring to be conducted during plant operation.

63 Related Environmental Measurement.iini Moni_t o r i rig P_rog rams When the applicant'> iite lies within.i region for which environ-monitoring programs are carried out hy public n.ent a l measurement o agencies or other agencies not directly suppo rt ed by t he applicant, any such related programs known to the applicin< should be identified and d i S cils S t'd.

Ne l eV 111ce oI

';ll C }l i!! dependent iindiogs lo the proposed raci1ity'> etfects should be described, and plans f o r exch.inge of intorma-t I ()lt, It it fly, :,Iltill l t! he f t's eill ed. t\\ g e!!c 1 t ct'S p()llS i h l e i G r lilt' })I og f.ImS s } loll [ d } Int' i deril I i I t'il, .lllil, lo ! !!c t'X l t'lll pt)s S i b ! f', llle p rof t'dlll es .l li d ille t Iloilo l(igy t'mjil t)yt'sl 5Ilt)l1 } 81 l>t b r i t* ! l y des c r i ht'd. o-8

7. ENVIROF 7TAL EFFECTS OF ACCIDENTS The applicant should discuss the environmental effects of possible accidents that may occur at the mill and during transportation of mate-rials to and f rom the mill, whether or not those acciderts may produce an impact on the site or its environs. Analyses should be based on relevant experience and statistics f rom operation of similar milling and transportation aperations. The statistical validity of the data should be discussed as well as the rationale for applying the data to the applicant's proposed operation. Accidents due to both man-caused and natural phenomena should be addressed. 7.1 Mill Accidents Involving Radioactivity The applicant should provide accident analyses for a spectrum of accidents that might occur ranging in severity from trivial (essentially no release of radicactivity to the environment) to very large releases. Each class within the spect rum should be characterized by an occurrence rate or probability and its potential consequences, if any. Examples of accidents resulting in large releases would be a tornado striking the mill er the failure of a waste retention system resulting from an act of nature or misoperation. Examples of accidents resulting in small releases would be a fire or explosion in a solvent extraction circuit or failure of the air cleaning system serving the yellowcake area during operation. An example of a trivial accident would be the malfunction of mill F.cocess equipment or the rupture of a vessel containing mill solutions. 7.2 Transportation Accidents The potential environmental effects from transportation accidents involving radioactive and other hazardous materials should be evaluated. 7-1 A3 '.) ^{ ^'

55ven though the probability of sucF an accident may be low and its con-sequences small, the applicant shc uld identif y the envi roinnental et tects t h a t. might result. Adequate docun entat ion should be present ed to pros ide assurance that all sa f ety requi rt ment s will he met prior t o transportation of hazardous materials (e.g., sp illage of ha za rdo u., chemicals, ores, fuels, yellow cake, sulf uric acid). 7.3 Other Accidents In addition to accidents that can release radioactivity to the environs, there may be accidents that, although radioactive materials are not invo!ved, do have consequences that affect the environment. Such accidents as (hemical explosions or tires, steam boiler failures, and leakage or rupture of vessels containing toxic mater als can have .significant environmental impacts 'Inese possible accidents ind asso-ciated et f ect s should be ident i fied and evaluated. O e ~ m m

8. ECONOMIC AND SOCIAL EFFECTS OF MILL CONSTRUCTION AND OPERATION The purpose of this chapter is to provide guidance on the information needed to assess the economic and social ef fects of the proposed facility. There are, of course, limitations on the extent to which all the social and economic benefits and costs of a uranium milling project can be evaluated. The wide variety of benefits and costs are not only diffi-cult to assess, but many are not amenable to quantification or even to estimation in commensurable units. Some primary benefits such as the quantity of uranium recovered are, to a degree, measurable as are the capital costs and operating and maintenance costs of the proposed facility. On the other hand, numerous environmental costs ani their economic and social consequences are not readi'y quantified. 8.1 Benefits The primary benefits of the proposed nuclear facility are those inherent in the value of the uranium to be recovered and the kilowatt-hours of electricity it represents. "he re are other social and economic benefits that affect various political jurisdictions or interests to a greater or lesser degree. Some of these reflect transfer payments or other values that may partially, if not fully, compensate for certain services as well as external or environmental costs, and this fact should be reflected in the designation of the benefit. The following lists some examples: Tax revenues to be received by local, State, and Federal governments. Temporary and permanent new jobs created and payroll (value-added concept). 8-1 142 234

Incremental increase in regional product. Enhancement of recreational values. Environmental enhancement in support of the propagation or protection of wildlife and the improvement of wildlife habitats. Creation and improvement of local roads, waterways, or other t ransporta-tion facilities. Increased knowledge of the environment as a consequence of ecological research and environmental monitoring activities associated with plant operation and technological improvements from the applicant's research program. The applicant should discuss significant benefits that may be realized from the construction and operation of the proposed mii. Where the benefits can be expressed in monetary terms, they slm .d be discounted to present worth. In each instance where a particular benefit is discussed, the applicant should indicate, to the extent practical, who is likely to be affected and for how long. In the case of esthetic impacts that are difficult to quantify, the applicant should provide pictorial drawings of structures or environmental modifications vi.ble to the public (refer to Section 3.2). 8.2 Costs The economic and social costs re. s ul t in g from the proposed nuclear f acility and its milling project are likewise complex and need to be appraised. are (1) the capital costs tI land acqui-The primary internal costs sition and improvement, (2) the capital costs of facility construction, 8-2 142 235

(3) other operating and maintenance costs, including license fees and taxes, (4) plant decommissioning, tailings stabilization, and site reclamation costs, and (5) research and development costs associated with potential future improvements of the mill and its operation and maintenance. As in the case of benefits, the applicant should discount these costs to present worth. There are also external costs. Their effects on the interests of people need to be examined. The applicant should supply, as applicable, an evaluation plus supporting data and rationale regarding such external social and economic costs. For each cost, the applicant should describe the probable number and location of the population group adversely affected, the estimated economic and social impact, and any special measures to be taken to alleviate the impact. Temporary external costs include shortages of housing; inflationary rentals or priceo; congestion of local streets and highways; noise and temporary esthetic disturbances; overloading of water supply and sewage treatment facilities; crowding of local schools, hospitals, or other public facilities; overtaxing of community services; and disruption of people's 1ives or the local community caused by acquisition of land for the proposed site. Long-term external costs include impairment of recreational values (e.g., reduced availability of desired species of wildlife and sport animals, restrictions on access to land or water areas preferred for recreational use); deterioration of esthetic and scenic values; restric-tions on access to areas of scenic, historic, or cultural interest; degradation of areas having historic, culturat, natural, or archeological value; removal of land from present or contemplated alternative uses; reduction of regional products because of displacement of persons from the land proposed for the site; lost income f rom recreation or tourism that may be impaired by environmental disturbances; lost income attributable 1A7 ') 8-3 (_ ) )

to environmental degradation; decrease in real estate values in areas adjacent to the proposed facility; increased costs to local governments fc r the services required by the permanently employed workers and their families. In discussing the costs, the applicant should indicate to the extent practical who is likely to be af fected and for how long. O 142 237 9 8-4

9. DECOT1ISSIONING AND RECLAMATION The applicant should describe in depth its plans for mill decommis-sioning and site reclamation. Detailed discussions should be provided for the following: a. Plans for reclaiming and restoring lands disturbed by mining and milling activities. b. A technical and financial feasibility assessment on methods and costs of mill decommissioning and site (including tailings area) reclamation. c. Financial arrangements to be made (such as bonding arrangements, etc.) to ensure that adequate funds will be available for mill decommissioning, site reclamation, and restoration when opera-tions are concluded. In th' discussion of rcclamation of tail. ags disposal areas, consider-ation shouid be given to the following post-reclamation performance objectives developed by the NRC staf f: a. Reduce d i. ce c t gamma radiation from the impoundment area to essentially background. b. Reduce the radon emanation rate from the impoundment area to about twice the emanation rate in the surrounding environs. c. Eliminate the need for an ongoing monitoring and maintenance program following successful reclamation. d. Provide surety arrangements to ensure that sufficient funds are available to complete the full reclamation plan. 142 238 9-1

9 10. ALTERNATIVES TO THE PROPOSED ACTION In this chapter of the environmental report, the applicant's choice particular site and the location of project of a particular mill at a structures on the site must be supported through a comparative evaluation of available alternatives. To the extent possible, the applicant shoold discuss all alternative parameters. The NRC will consider all available alternatives that may reduce or avoid adverse environment..1, social, and economic effects expected to result from construction and operation of the proposed milling and mining project. The NRC will not specify in advance which a l t.e rna t ive s should be selected by the applicant for consideration; rather, the applicant should make this selection and also make clear the basis and rationale for the choices in regard to number, availability, suitability, and factors limiting the range of alternatives that might avoid some or all of the environmental effects previously identified. Particular attention should be placed on the relationship 9 between tailings management alternatives and mill site and process alternatives. In the discussion of tailings management alternatives, considera-tion should be given to the following siting, design, and operation performance objectives developed by the staff in addition to the post-reclamation performance objectives listed in Chapter 9: a. Locate the tailings isolation area remote from people in order to reduce population exposures to the maximum extent reasonably achievable. b. Locate the tailings isolation area so that disruption and dispersion by natural forces is eliminated or reduced to the maximum extent reasonably achievable. 10-1 142 239

c. Design the isolation area so that seepage of toxic materials into the ground-water system would be eliminated or reduced to the maximum extent reasonably achievable. d. Eliminate the blowing of tailings to unrestricted areas during normal operating conditions and prior to. inal reclamation. O 10-2 kkb

11. BENEFIT-COST ANALYSIS In this chapter the applicant's benefit-cost statement should be presented. The presentation should be made in the form of a narrative with accompanying tables and charts. It should make clear what the applicant considers to be the important benefits and costs of the pro-posed f acility and why, in the judgment of the applicant, the former outweigh the latter. The applicant will have to develop criteria for assessing and com-paring benefits and costs where these are expressed in nonmonetary or qualitative terms. The rationales for the selection among site-mill alternatives, as well as among subsystem alternatives, should be pre-sented. In any case, '.he applicant should carefully describe any aggre-gation of effects and discuss in detail the tradeoffs that were made in order to justify the proposed operation. If any of the benefits or costs are deleted from the applicant's enalysis, the rationale for doing so should be explained. The applicant should key all the terms used in the benefit-cost analysis to the relevant sections of the environmental report. 11-1 l42 24i

12. ENVIRONMENTAL APPROVALS AND CONSULTATIONS List all licenses, permits, and other approvals of construction and operations required by Federal, State, local, and regional authorities for the protection of the environment.' List those Federal and State approvals that have already been received and indicate the status of matters regarding approvals yet to be obtained. For general background, submit similar information regarding approvals, licenses, and contacts with local authorities. Discuss the status of efforts to obtain a water quality certifica-tien under Section 401 and discharge permits under Section 402 of the Federal Water Pollution Control Act, as amended. If not already obtained, indicate when certification is expected. If certification is not required, explain. In view of the effects of the plant on the economic development of the region in which it is located, the applicant should also note the State, local, and regicnal planning authorities contacted or consulted. Office of Management and Budget Circular A-95** identifies the State, metropolitan, and regional clearinghouse that should be contacted, as appropriate. Cite meetings held with environmental and other citizen groups with reference given to specific instances of the applicant's compliance with citizen group recommendations. This list should be updated bimonthly until final action is taken by the NRC. Inquiries concerning this circular may be addressed to the Of fice of Management and Budget, Washington, D.C. 20503. ,) k k d-12-1

13. REFERENCES The applicant should provide a bibliography of all sources used in Preparation of the environmental report. References cited should be keyed to the specific sections and page numbers to which they apply. 13-1

4 e APPENDIX A SUGGESTED FORMAT FOR REPORTING RADIOLOGICAL PARAMETERS 142 244

O-TABLE A-1 AVERAGE ANNUAL RADIOACTIVE NUCLIDE EMISSIONS (in curies) DURING ACTIVE MILLING AND MINING OPERATIONS Nuclide Y Source U-238 U-234 Th-230 Ra-226 Rn-222 Pb-210 Mine Ore Pad and Feeding Grinding Uranitm Concentrating and Packaging Tailings N N 4 LTl

O TABLE A-2 PRINCIPAL P/ RAMETERS FOR RA9IOLOGICAL ASSESSMENT Parameter Valne Ore quality, U 0 33 Ore activity, U-238, U-234, Th-230, Ra-22ts, and Pb-210 pCi/g Operating days per yea. (plant factor) days Ore process rate ____ tonnes /yr F'< traction etficiency ___________4 Ye!'owcake yield tonnes /yr Yellowcake quality, U O 3g Yellowcake drying stack etfluent, UO __ _kg/yr 3g Yellowcake drying stack filter ef ficiency _____..________________.o Total mine area m o Active mine area m Average m i lle depth rii Average hauling distance m Total tailings area m Tailings pond (solution) area m Tailings impoundment depth (20th year) m l'a i 1 i n gs density - - - _ - _ _ _ _ - _ _g/cm Seepage rate from tailings impoundment gpm Fraction U, Th-230, Ra-22ti, and Pb-210 to Lai1ings 't Mill water throughput /yr m Ore pad area and height m m Ore storage time days Tailings activity, U, Ra-2 %, Th-2 30, and Fb-i.C in s1imes pCi/g Tailings activity, U, Ra-226, Th-230, and Pb-210 in ;and pCi/g railings activity, U, Ra-226, Th-230, and Pb-?l0 in solution pCi/l A-2 142 246

UN'TE D ST ATES O NUCLEAR RE Gut.A TOR Y COMMISSION W ASHING TON, D. C. 20555 rost Act Ano rE Es P Ato OFFICI AL BUSINESS couu, g,og U S MAJL PEN ALT Y FOR PRIV ATE USE $300 L~J O wL L 't /}}