/ma - i PDe
\\^
NUCLEAR REGULAIGRY COMMISSION UNITED ST ATEs
-j 4r W ASHINGTON D. C. 20%5 A
y y9:a,/l JUN 5 G79
- 3GML : r t.J
'0-1113 General Electric Companj ATTN: Mr. A. L. Kaplan, Manager Licensing and Compliance Audits Mail Stop J-26 P. O. Cox 780 Wilmington, North Carolina 28401 Gentlemen:
i This is in response to your letters of April 2, 4 and May 4,1979 whit, were argmented by discussions held at NRC Headquarters between General Electric - Wilmington and Division of Safeguards personnel on April 4, 20 and May 31, 1979.
We have reviewed your submittal, " Application Amendment S-8 For Physical inventory of UO, Pellets and Certain Containers of SNM," dated April 2,197-together with mbdifications 1 and 2 submitted April 4 and May 4, 1979, We have detennined that the application does not meet the respectively.
requirer.,ents of 10 CFR 70.51(e)(4),10 CFR 70.51(f)(2)(iii),10 CFR 70.51(f)
Your application is deficient in that it doe' (3)(ii), and 10 CFR 70.53(b).1) the remeasurement, at the time of physical inventory not provide for:
all meterial for which the validity of previously made measurements has not been assured by tamper-safing and 2) the calculation, reconciliation and reporting of material unaccounted for within 30 calendar days after the start Accordingly, your request for approval of the of the physical inventory.
application is hereby denied.
We understand that you have arranged to meet with Mr. R. F. Burnett on June 8, 1979 to discuss this matter.
It has been established that the attachments to your letters of April 2 and 4
()
dnd May 4,1979 contain information of a type specified in 10 CFR 2.790 d.
Accordingly, pursuant to Section 2.790(d)(1), such information is deemed to be commercial or financial information within the meaning of 10 CFR 9.5(a)(4) and shall be subject to disclosure only in accordance with the provisions of 10 CFR 9.12.
Sincerely, (M