, p a cg,'o, Mr{.

UNITED STATES l

ET NUCLEAR REGULATORY COMMISSION 7;

$.,k.~h*'%

l., '

E REGION V o'[rits, E

1990 N. C AllFORNI A COULEVARD gh SUITE 202, WALNUT CREEK PLAZA e

o e,,,e WALNUT CitEEK, CALIFORNI A 94S96 July 10,1979 Docket ilo. 50-344 Portland General Electric Company 121 S. W. Salmon Street Portland, Oregon 97204 Attention: Mr. Charles Goodwin Assistant ' lice President Gen cl e:r,en :

In accordance with cur letter dated April 1,1979 transmitting Bulletin 79-05, we are enclosing Preliminary i;otification 79-67AW.

Sincerely,

/; f / 9, yc c L R. H. Engelken Cirector Enclosure P:10-79-67AW cc w/ enclosure:

B. Withers, PGE F. Gaidos, PGE 460 U17

%%%%om 7908020 g g

y es w m

.jdegij Q.

i l

1 l

INEDIATE PRELIMIMRY NOTIFICMION i.

PRELIMINARY WTIF.' 'ATIcN OF EVENT OR UNUstill OCCUARENCE--PNO-79 il y

This orslininary notification orovidas updated informatic, of safsty or 3_Q puolic int.orast Gicnificacca.

Q

,ygk*d b 4's q

?

l 4

FACILITY:

Thrw Mile Island, Unit 2 R '[;v ^ '.,%5 ?

Middleton, Psnnsylvania (DN 50-320)

J f 5f c

3 y

' G;-

'L'

/

' ',,.. f' )F

SUBJECT:

tJPJATED STATUS REPOJtT r

1

'M&{

Ct>vrs ti ce.al :

t 1

g j

i 1.

Averaqa cuolant taparaturs is 165 dagrees F.

The highest incors ther w couple terperature indication is 270 dagroe3 F.

Corn ficw is being provid4d[by natural circul ation.

Core cooling is biting uaintained by st antir>:; the "A" Stam Canarstar to the.sain condenser on the bypaas valve.

Printry pressure is about 275 psi.

I 2.

Daily 2:easurmonts of rsactor building water level still indicata 7.0 i h.5 in*t above floor level.

t 1 Functienal testing of the Pressurs/Volu>e Control syste.a has begun a,d will continue throughout the wek.

hvi - u n to--

Environ,= ental adiation levels remain consistant with natural background ley 915.

Airborne releases rs.>ain well belev Technical Specification limits.

From t

July 2 - July 8,1979, 23 sir suples. 2 nilk supiss, 4 vcCatation samples gnd 2 so'l smples were collected by the NRC.

All analytical ra3ults era less thm MOA.

EPA air, watar, and :ailk sagles collected during the wwk (ep to Julyi4) showed no detectable activity frcss TMI.

f(r[$ [7 6 h

l.

Contact:

DThomson IE, x28487 RPaulus IE, x27246 J

0.YOf Distribution:

Transmitted H St 'f ' */ F

'"4!y*fjjjjj 1 Chair:::an Hendrie ccavaission9r Bradford S. J. Chilk, SECY

' #Se Ccmaissioner Xannedy Cownissioner A.hoarra C. C. Kam.arar CA g

Ccealssionar Gilinsky (For Distribution)

Ws Transmittad:

>>E3 4/,' 5*0 P. Bleg e ;

J. G. Davis, IE t

L. V. Gossick, ECO geh H. R. Conton, NRR Region I J M T

[

H.L.Ornstein,ECOue,.,h R. C. DeYoung, NRR

' legion Il s'N "/

J. J. Fouchard, PA R. J. Mattson, NRR Reglon III

-,h.c H. M. Haller, MPA V. Stallo. NRR Ragion IV

-p g E R. G. Fysn, OSP

2. S. Boyd, NRR P'gion V _ R 2 1

!!. :' Separ. ELD S5 31cg

'/ : i'T e l

(:ML) i.

11. J.

Direxs, AMS$ t.

J.

J.~ Cu mings, DIA S. Lavine. RES R. ?tirogu*, 50 p

v LCMTINUED qQQ

]}@

19 0 717 0 't 6 3 l

o i

3.

~ ' ' " -

4* 5 W 3**E'M y;.-,,.,-._

_ %r.

4

)

. n I

!r i

I 4

Ph0-79-67-/N 2-7j9779

}

Continued -

'*~

,' I.'

t IE (TMI) Site MM (Provide copy to STATE)

}

3;

~

e. Abrsham, PA (Middletown - T91-Information Cantar) 5htta House Situation 3oco I

i

!(-

FDAA (Provide cepf es to tha Administrator and the Operations Centar)

E?A i

3 bbkM t

PEM t l' ORP (5t.ata of PA)

CcrA lj' ttEM i.

Hanocarry (FAA) if f

I.WOLUC PRELINUuRY MOTIFICATION il

'l 9-I t

,I.

.I

!}

-@\\ - y

r J.

=..

. v.;

.a,

1

' *- ?

e-d C'

~?

.e m-o..

a.

I t m

t

,4 I

I' '

l v.

tt 3

a op t-6 i

);

460 u,,t,

g t r,

.i a

m..

a.

s.

t3 I f 9.

C T i:

3,1 i

.$ 1 a

r%'

l!

  • v:

1.

E tt l!

..m-.- m EO ' U ",,c ~

,l L.

,I 6

/

ao N/?g n )/}! M,A h f

r0.' '

,q' 5

I D lj' s i wkag,f

' 't 9 f

fa

,a p' ' r i.

j *,

I i

.-~.v.}