ML19240A983

From kanterella
Jump to navigation Jump to search
COL Docs - FW: Discussion on LAR 19-013
ML19240A983
Person / Time
Site: Vogtle  
Issue date: 08/28/2019
From:
NRC
To:
NRC/NRO/DLSE/LB4
References
Download: ML19240A983 (2)


Text

1 Vogtle PEmails From:

Patel, Chandu Sent:

Wednesday, August 28, 2019 1:08 PM To:

Vogtle PEmails Cc:

Rankin, Jennivine

Subject:

FW: Discussion on LAR 19-013 Discussion topic for a public meeting From: Patel, Chandu Sent: Wednesday, August 28, 2019 10:51 AM To: Leighty, Steven <sleighty@southernco.COM>; Roberts, Kelli Anne <KROBERTS@southernco.com>

Cc: Rankin, Jennivine <Jennivine.Rankin@nrc.gov>

Subject:

Discussion on LAR 19-013 Hi Steve and Kellie, We would like to discuss this issue ASAP. When do you think you can support. Do you think we can do it tomorrow? If not, we can handle it as a clarification call out of Thursdays call to expedite the process. Please let us know. I think we may be able to include it as a last minute change.

The following paragraph is in the LAR (ML19207A727) Section 3.4, First Plant Testing:

The applicability of the Sanmen Unit 1 first plant surge line monitoring to Vogtle Units 3 and 4 was confirmed by verifying the systems, structures and components (SSCs) within the scope of the surge line monitoring requirement were designed using the same standard AP1000 design requirements across Sanmen Unit 1 and Vogtle Units 3 & 4. Reviews were completed of design documents specific to the Sanmen Unit 1 surge line to confirm there were no site-specific deviations that would invalidate the surge line data from being used at Vogtle Units 3 and 4. Similarly, Sanmen Unit 1 heat up and cooldown procedures and transients were reviewed which also confirmed that the changes and transients did not invalidate the surge line data from being used at Vogtle Units 3 and 4.

The highlighted part is what we would like to discuss with SNC. During the 6/27/2019 public meeting phone call, part of the feedback provided to SNC was that the applicability of the Sanmen Unit 1 first plant surge line monitoring to Vogtle Units 3 and 4 is valid if the heatup and cooldown procedures of Vogtle 3 & 4 are identical to those of Sanmen Unit 1 (see public meeting memo ML19190A319). And if that is the case, the LAR should clearly demonstrate that.

Thanks, Chandu Patel, Senior Project Manager U.S. NRC, Office of New Reactors NRC/NRO/DNRL/LB4, Washington, DC 20555-0001 301.415.3025

Hearing Identifier:

Vogtle_COL_Docs_Public Email Number:

474 Mail Envelope Properties (BYAPR09MB296848935467CA1908E9A66582A30)

Subject:

FW: Discussion on LAR 19-013 Sent Date:

8/28/2019 1:08:09 PM Received Date:

8/28/2019 1:08:11 PM From:

Patel, Chandu Created By:

Chandu.Patel@nrc.gov Recipients:

"Rankin, Jennivine" <Jennivine.Rankin@nrc.gov>

Tracking Status: None "Vogtle PEmails" <Vogtle.PEmails@nrc.gov>

Tracking Status: None Post Office:

BYAPR09MB2968.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 2166 8/28/2019 1:08:11 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: