BOSTON EDISON COMPANY GENERAL omCES 800 BoyLRTON STREET B O S TQ N. M A S S A C H U S ETTS o2199
- c. CARL ANOCGNiN1 MANAGER NUCLEAR QPER ATIONS DEPARTMENT May 20, 1979 BECo. Ltr. #79-95 Mr. Eldon J. Brunner, Chief Reactor Operations and Nuclear Support Branch Office of Inspection and Enforcement Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA.
19406 License No. DPR-35 Docket No. 50-293 Response to IE Inspection No. 79-04
Dear Sir:
Inspection No. 79-04, dated April 26, 1979, contained one item of non-compliance.
Boston Edison Company's response to that item is presented as follows:
Deficiency Technical Specification (TS) 4.7.D.1.b(2) requires that reactor power be less than 50" when tripping the main steam isolation valves individually, and verifying closure ti e.
Contrary to the above, Procedure Number 8.7.4.4, Main Steam Isolation Valve Trip, written to satisfy the above TS requirement contained acceptance criteria allowing the surveillance test to be perfor=ed at a reactor power less than 60%,
a less conservative value.
Further, surveillance tests performed May 28, 1978 and February 18, 1978 were conducted at reactor power levels of 55% and 52.5%,
respectively.
Respoase Procedure Number 8.7.4.4 has been changed and is now in conformance with the 50%
reactor power limitation as stated in the Technical Specifications.
A Technical Specification change to remove the power restriction requirement is currently in draft form and will be submitted in a subsequent letter.
790720cd 366 030
+
BOSTON 'EoisoN COMPANY Mr. Eldon J. Brunner, Chief May 20, 1979 Page 2 At the present time we are in compliance in this area.
We 'oelieve that this letter is responsive to your concerns.