ML19225A525
Jump to navigation
Jump to search
| ML19225A525 | |
| Person / Time | |
|---|---|
| Site: | Dresden |
| Issue date: | 05/10/1979 |
| From: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | |
| Shared Package | |
| ML19225A522 | List: |
| References | |
| 50-010-79-08, 50-10-79-8, 50-237-79-12, 50-249-79-10, NUDOCS 7907190497 | |
| Download: ML19225A525 (1) | |
Text
.
Appendix A NOTICE OF VIOLATION Commonwealth Edison Docket No. 50-237 Company Based on the inspection conducted on April 2-30, 1979, it appears that certain of your activities were in noncompliance with NRC requirements, as noted below.
This item is an infraction.
Unit 2 Technical Specifications, Section 3.7.A.1 requires the maximum volume in the torus to be 115,655 cubic feet.
Contrary to the above, during a quarterly flow test and sub-sequent troubleshooting of the HPCI System on January 3, 1979, the technical specification required maximum volume in the torus was exceeded.
IUO7190497 353 OjftD