Forwards Suppl IE Bulletin 79-01A, Environ Qualification of Class IE Equipment (Deficiencies in Environ Qualification of Asco Solenoid Valves). No Action Required
ML19225A487
Person / Time
Site: Fort Calhoun 
Issue date: 06/06/1979
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Short T
OMAHA PUBLIC POWER DISTRICT
References
NUDOCS 7907190407
Download: ML19225A487 (1)


Text

CENTRAL FILES PDR:HQ f

'"'4 t*

9 y

p, UNITED STATES R

y#(f(1 NUCLEAR REGULATORY COMMISSION 2

p USIC

$ W,0#/.- E REGION IV 9,%db[#[

611 RYAN PLAZA DRIVE, SUITE 1000

'D AR LINGTON, TEX AS 7F012 9

,o

  • ese*

June 6, 1979 Docket No.

50-285 Omaha Public Power District ATTN:

T. E. Short, Assistant General Manager 1623 Ilarney Street Omaha, Nebraska 68102 Gentlemen:

Enclosed is supplement IS Bulletin 79-01A.

It requires action by you with regard to power reactor facilities with an operating license except for the 11 SEP plants which are listed in Enclosure 3.

This Bulletin is also being sent for information to the 11 SEP plants and all power reactor facilities with a construction permit.

No action or written response is required for construction permit facilities or the 11 SEP plants.

Should you have questions regarding this Bulletin or the actions required of you, please contact thic office.

Sincerely, Karl V. Seyfrit/

Director

Enclosures:

1.

IE Bulletin No.79-01A 2.

List of IE Bulletins Issued in the Last 12 Months 3.

List of SEP Plants (11) cc:

R. L. Andrews, Manager Fort Calhoun Station Post Office Box 98 Fort Calhoun, Nebraska 68102 420 163 gd) 7907100407

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Bulletin No.79-01A Date:

June 6, IW 9 Page 1 of 3 SUPPLEMENT NO.79-01A TO IE BULLETIN 79 E1WIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT (DEFICIENCIES IN THE ENVIRONMENTAL QUALIFICATION OF ASCO SOLEN 0ID VALVES)

Description of Circumstances:

Recently, a noncomplia.ce report under 10 CFR Part 21 was received by the NRC from the Henry Pratt Company, manufacturer of butterfly valves which are installed in the primary containment at the Three Mile Island Unit 2 Nuclear Station. These butterfly valves are used for purge and exhaust purposes and are required to operate during accident conditions. The report discusses the use of an unqualified solenoid valve for a safety-related valve function which requires operation under accident conditions. The solenoid valve in question is Catalogue No. HT-8331A45, manufactured by the Automatic Switch Company (ASCO) of Florham Park, New Jersey. This pilot valve is used to pilot control the pneumatic valve actuators which are installed on the containment ventila-tion butterfly valves at this facility.

The deficiency in these solenoid valves identified in the Part 21 Report concerns the parts made of acetal plastic material. The acetal disc holder assembly and, bottom plug in the pilot valve assembly are stated by ASCO to have a maximum service limit of 400,000 Rad integrated dosage and 200 degrees F temperature.

According to ASCO, exposure of these acetal plastic parts to specified maximum environmental conditions may render the solenoid pilot valve inoperable which would cause the associated butterfly valve to malfunction.

Further ir.vestigation at ASCO by the NRC staff has revealed that the valve seals in cost ASCO solenoid valves contain Buna "N" elastomer material, which reportedly has a maximum service limit of 7,000,000 Rad integrated dosage and 180 degrees F temperature.

The investigation further revealed that ASCO has available a line of qualified solenoid operated pilot valves (ASCO Catalogue No. NP-1) which have no plastic parts, utilize ethylene propylene or viton elastomers and have a continuously energized operating life of four years, under normal ambient conditions up to 140 degrees F.

According to the manu-facturer, at the end of this period, thg coil, manual operator (optional fea-ture) and all resilient parts must be rq ~ -

W "+ m intenance instructions are specified in the insta]

DUPLICATE DOCUMENT 7

are provided to the purchaser with each hd #-t previously entered The final items of concern identified d int sys e application of Class "A," "B," or "F,"

i accident environ =ent.

In this regard, ANO_7 9O70 @ ]

j T64 t

No-of Pages:

[

j J3,-

\\

3 1-q o

-d