ML19225A476

From kanterella
Jump to navigation Jump to search
Forwards Suppl IE Bulletin 79-01A, Environ Qualification of Class IE Equipment (Deficiencies in Environ Qualification of Asco Solenoid Valves). No Action Required
ML19225A476
Person / Time
Site: River Bend  
Issue date: 06/06/1979
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Weigand J
GULF STATES UTILITIES CO.
References
NUDOCS 7907190393
Download: ML19225A476 (1)


Text

"; fg 01N%,

o UNITED STATES

! j ',.e. ('( ';

NUCLEAR REGULATORY COMMISSION

fi C,/.

C REGION IV SNkh

[

011 HYAN PLAZA DRIVE, SulTE 1000

%, ' W

,o#

ARLINGTON, TEXAS 76012 C

+....

June 6, 1979 In Reply Refer To:

RIV Docket Nos.

50-458/IE Bulletin No.79-01A 50-459/IE Bulletin No.79-01A Gulf States Utilities Attn:

Dr. J. G. Weigand General Manager, Nuclear Projects Post Office Box 2951 Beaumont, Texas 77704 Gentlemen:

Enclosed is supplement IE Bulletin 79-01A.

It requires action by you with regard to power reactor facilities with an operating license except for the 11 SEP plants which are listed in Enclosure 3.

This Bulletin is also being sent for information to the 11 SEP plants and all power reactor facilities with a construction permit.

No action or written response is required for construction permit facilities or the 11 SEP plants.

Should you have questions regarding this Bulletin or the actions required of you, please contact this office.

Sincerely, Karl V. Seyfr Director Enclosures.

1.

IE Bulletin No.79-01A 2.

List of IE Bulletins Issued in the Last 12 Months 3.

List of SEP Plants (11) 420 144 790719039 3 h

UNITED STATES NUCLEAR REG!ILATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Bulletin No.79-01A Date: June 6, 1979 Page 1 of 3 SUPPLEMENT NO.79-01A TO IE BULLETIN 79 ENVIRONMENTAL QUALIFICATION OF CLASS 1E EQUIPMENT (DEFICIENCIES IN THE ENVIRONMENTAL QUALIFICATION OF ASCO SOLEN 0ID VALVES)

Description of Circumstances:

Recently, a noncompliance report under 10 CFR Part 21 was received by the NRC from the Henry Pratt Company, manufacturer of butterfly valves which are installed in the primary containment at the Three Mile Island Unit 2 Nuclear Station. These butterfly valves are used for purge and exhaust purposes and are required to operate during accident conditions. The report discusses the use of an unqualified solenoid valve for a safety-related valve function which requires operation under accident conditions. The solenoid valve in question is Catalogue No. HT-8331A45, manufactured by the Automatic Switch Company (ASCO) of Florham Park, New Jersey. This pilot valve is used to pilot control the pneumatic valve actuators which are installed on the containment ventila-tion butterfly valves at this facility.

The deficiency in these solenoid valves identified in the Part 21 Report concerns the parts made of acetal plastic material.

The acetal dice holder assembly and bottom plug in the pilot valve assembly are stated by ASCO to have a maximum service limit of 400,000 Rad integrated dosage and 200 degrees F temperature. According to ASCO, exposure of these acetal plastic parts to specified maximum environmental conditions may render the solenoid pilot valve inoperable which would cause the associated butterfly valve to malfunction.

Further investigation at ASCO by the h3C staff has revealed that the valve seals in most ASCO solenoid valves contain Buna "N" clastomer material, which reportedly has a maximum service limit. of 7,000,000 Rad integrated dosage and IPO degrees F temperature. The investigation further revealed that ASCO has available a line of qualified solenoid operated pilot valves (ASr0 Catalogue No. NP-1) which have no plastic parts, utilize ethylene propylene or viton elastomers and have a continuously energized operating life of four years, under normal ambient conditions up to 140 degrees F.

According to the manu-facturer, at the end of this period, th;

% val operator (optional fea-ture) and all resilient parts must be d ' j DUPLICATE instructionsarespecifiedintheinst(j T

~

are provided to the purchaser with each IEntire d U

finto system under:ent previous 2y entered The final items of concern identified,

application of Class "A," "B," or "F,"

ANO 70 W accident environment.

In this regard,

/( W (/g No.

Pages:

p

,f-

/u" Q 1 't D L!

_. _ _