Forwards IE Bulletin 79-14, Seismic Analysis for As-Built Safety-Related Piping Sys. Action Required
ML19225A298
Person / Time
Site: Maine Yankee
Issue date: 07/02/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Groce R
Maine Yankee
References
NUDOCS 7907180776
Download: ML19225A298 (1)


Text

y[

[o, UNITEc ;ATES y,

g NUCLEAR REGULAl-. RY COMMISSION

- C REGION I S

[

631 PARK AVENUE

,o#

KING OF PRUSSIA, PENNSYLVANIA 19406

\\d Docket No. 50-309 Ji!L :

3 Maine Yankee Atomic Power Company ATTN

Mr. Robert H. Groce Licensing Engineer 20 Turnpike Road Westborough, Massachusetts 01581 Gentlemen:

The enclosed Bulletin 79-14 is forwarded to you for action. Written responses are required.

If you desire additional information regarding this matter, please contact this office.

Sincerely,

},3 f

w/Y,

.6-oyce H. Grier d irector

Enclosures:

1.

IE Bulletin No. 79-14 2.

List of IE Bulletins Issued in Last 12 Months cc w/encls:

E. Wood, Plant Superintendent E. W. Thurlow, President US 067 an. 2co 77c

ENCLOSURE 1 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C.

20555 IE Bulletin No. 79-14 Date:

July 2, 1979 Page 1 of 3 SE.TSMIC ANALYSES FOR AS-BUILT SAFETY-RELATED PIPING SYSTEMS Description of Circumstances:

Recently two issues were identified which caa cause seismic analysis of safety-related piping systems to yield nonconservac.ive results.

One issue involved algebraic summation of loads in some seismic analyses.

This was addressed in show cause orders for Beaver Valley, Fitzpatrick, Maine Yankee and Surry.

It was also addressed in IE Balletin 79-07 which was sent to all power reactor licensees.

The other issue involves the accuracy of the information irput for seismic analyses.

In this regard, several potentially unconservatte factors were discovered and subsequently addressed in IE Bulletin 79-02 (pipe supports) and 79-04 (valve weights).

During resolution of these concerns, inspection by IE and by licensees of the as-built confiauration of several piping systems revealed a number of nonconformances te design documents which could potentially affect the validity of seismic analyses.

Nonconformances are identified in Appendix A to this bulletin.

Because apparently significant non-conformances to design documents have occurred in a number of plants, this issue is generic.

The staff has determined, where design specifications and drawings are used to obtain inpet information for seismic analysis of safety-related piping systems, that it is essential for these documents to reflect as-built con-figurations.

Where subsequent use, damage or modifications affect the con-dition er cnnfiguration of safety-related piping systems as described in documents from which seismic analysis input information was obtained, the licensee must consider the need to re-evaluate the seismic analyses to con-sider the as-built configuration.

Action to be taken by Licensees und Permit Holders:

All power reacter facility licensees and construction permit holders are requested to verify, unless verified to an equivalent degree within the last 12 months, that the seismic analysis applies to the actual configura-tion of safety-related piping s' j" ' ' - "' nininn includes Seismic Category I systems as d' jDUPLICATE DOCUMENT