Forwards IE Bulletin 79-13, Cracking in Feedwater Sys Piping. No Action Required
ML19224D612
Person / Time
Site: 05000484
Issue date: 06/25/1979
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Dienhart A
NORTHERN STATES POWER CO.
References
NUDOCS 7907130142
Download: ML19224D612 (1)


Text

T

[

[

  • W,k UNITED STATES 4

NUC LE AR REGULATORY COMMISSION

f.,

REGloN 111 l ;,

s 799 ROOSE V E LT RO AD G LE N E L L Y N. IL LINOIS 60137 Q'

' 4 a

0,,. *g June 25, 1979 Docket No. 50-484 Northern States Power Company ATTN:

Mr. A. V. Dienhart Vice President - Tyrone Energy Park 100 North Barstow Street Eau Claire, WI 54701 Gentlemen:

The enclosed IE Bulletin No. 79-13 is forwarded to you for information.

No written response is required.

If you desire additional information regarding this matter, please contact this office.

Sincerely, f

2A~

- Tames G. Keppler Director Enclosurc.s:

1. IE Bulletin No 79-13
2. Listing of IE Bulletins Issued in Last 12 Months cc w/ encls:

Central Files Director, NRR/ DPM Director, NRR/ D0R PDR Local PDR NSIC TIC Regions I & IV 369 048

/ }l 9 7907130 #8 k

U.S. NUCLEAR REGULATouY COMMISS'.ON OFFICE OF INSPECTION AND ENFORCEMENT REGION III June 25, 1979 IE Bulletin No. 79-13 CRACKING IN TEEDWATER SYSTEM PIPING Description of Circumstances:

On May 20, 1979, Indiana and Michigan Power Company notified the NRC of cracking in two feedwater lines at their D. C. Cook Unit 2 facility. The cracking was discovered following a shutdown on May 19 to investigate leakage inside containment. Leaking circumferential cracks were identified in the 16-inch feedwater elbows adjacent to two steam generator nozzle elbow welds.

Subsequent radiographic examination revealed crack iadications in all eight steam generator feedwater lines at this location on both Units 1 and 2.

On May 25, 1979, a letter was sent to all PWR licensees by the Office of Nuclear Reactor Regulation which informed licensees of the D. C. Cook failures and requested specific information on feedwater system design, fabrication, inspection and operating histories. To further explore the generic nature of the cracking problem, the Office of Inspection and Enforcement requested licensees of PWR plants in current outages to immediately conduct volumetric examination of certain feedwater piping welds.

As a result of these actions, several other licensees with Westinghouse steam generators reported crack indications. Southern California Edison reported on June 5, 1979, that radiographic examination revealed indications of cracking in feedwater nozzle-to-piping welds on two of three steam generators of San Onofre Unit 1.

On June 15, 1979, Carolina Power and Light reported that radiography showed crack indications in similar locations at their H. B. Robinson Unit 2.

Duquesne Power and Light confirmed on June 18, 1979, that radiography has shown cracking in their Beaver Valley Unit 1 feedwater piping to vessel nozzle weld. Public Service Electric and Gas Company reported on June 20, 1979 that Salem Unit 1 also has crack indications. Wisconsin Public Service company decided on June 20, 1979 to cut out a feedwater nozzle-to-pipe weld which contained questionable indication, for metallurgical examination. As of June 22, 1979 and since May 25, 1979 seven other PWR facilities have inspected the feedwater nozzle-to-pipe welds without finding cracking indications.

The feedwater nozzle-to-pipe configurations for D.C. Cook and for San Cnofre are shown on the attached figures 1 and 2.

A typical feedwater pipe-to-nozzle weld joint detail showing the principal crack locations for D.C. Cook and San Onofre are shown on the attached figure 3.

m-

.m m._

on March 17, 1977, during heat-up for hot DUPLICATE DOCUMENT Unit 1, a leak was discovered in the vesse

(

the 16-inch diameter feedwater piping to s e

nondestructive examination of all nozzle w h Entire doctunent previously entered Into system under:

k

- i ANO

~~/900'1 9 348' f vases:

la 369 049 1

(

.c

.