Forwards IE Info Notice 79-17, Source Holder Assembly Damage from Misfit Between Assembly & Reactor Upper Grid Plate
ML19224C457
Person / Time
Site: Dresden, Byron, Braidwood, Quad Cities, Zion, LaSalle  
Issue date: 06/20/1979
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Brian Lee
COMMONWEALTH EDISON CO.
References
NUDOCS 7907020409
Download: ML19224C457 (1)


Text

o arco

/

'o, UNITED STATES

[ ',,.,. '. [g NUCLEAR REGULATORY COMMISSION g.'

,/

r REGION lli o,

799 ROOSEVELT ROAD NW j' GLEN Y.

S 60137 Docket Nos. 50-10, 50-237, 50-249, 50.-254, 50-265, 50-205, 50-504, 50-373, 50-374, 50-454, 50-455, 50-456 and 50-457 Commonwealth Edison Company ATTN:

Mr. Byron Lee, Jr.

Vice President Post Office Box 767 Chicago, IL 60690 Gentlemen:

This Information Notice No. 79-17 is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities.

No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding this matter, please contact the Director of this office.

Sincerely, hb

(/ James G. Kepp er Director

Enclosure:

IE Information Notice No. 79-17 cc w/ encl:

Mr. B. B. Stephenson, Mr. R. Cosaro, Project Station Superintendent Superintendent Mr. N. Kalivianakis, Central Files Station Superintendent Director, NRR/DPM Mr. N. Wandke, Station Director, NRR/ DOR Superintendent PDR Mr. L. J. Burke, Site Local PDR Project Superintendent NSIC Mr. T. E. Quaka, Quality TIC Assurance Supervisor Anthony Roisman, Esq.,

Mr. R. H. Holyoak, Station Attorney Superintendent Mr. Dean Hansell, Office Mr. Gunner Sorensen, Site of Assistant Attorney Project Superintendent General 271 298 7 9 0 7 0 2 0"C9 q

U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMFNT REGION III June 20 1979 IE Infomation Notice hv. 79-17 SOURCE HOLDER ASSEMBLY DAMAGE FROM MISFIT BETVEEN ASSEMBLY AND REACTOR UPPER GRID PLATE Description of Circumstances:

Recently, the NRC was infomed of a problem at two Westinghouse PWR facilities resulting from an apparent misfit between secondary source holder assemblies and the reactor upper grid plate.

The misfit problem was first identified by Carolina Power & Light, licensee for H. B. Robinson Unit 2, who infomed the NRC on May 6,1979, of the circum-stances. During the current refueling outage at H. B. Robinson 2, CP&L deter-mined that two secondary source holder assemblies had been damaged during the previous refueling in February 1978, by a misfit between the assembly and the reactor upper grid plate. The misfit resulted from insufficient clearance (i.e. 1/2 to 3/4 inch) between the source holder assembly hub and the grid plate at the core locations containing thermocouple mixing vanes. This lack of sufficient clearance caused minor deformation of the uppcr grid plate com-ponents at the core location and of the source holder assemblies. The deforma-tion also resulted in some bending of the fuel rods in the assembly, however, in no case did this bending result in fuel cladding perforation.

On May 16, 1979, the licensee of D. C. Cook Unit 1 infomed the NRC that the present refueling outage would be extended 15 to 20 days to remove the reactor head, which had already been reinstalled following completion of refueling, to correct this misfit problem. They learned of.the problem from Westinghouse.

Subsequently, the licensee's inspection revealed that the source holder asse::.bly hubs were in contact with the vanes. The source holder was removed from cne assembly readily with no apparent damage while in the other the source holder was found stuck in the assembly. The problem was corrected prior to return to operations.

The secendary source assembly rods are normally inserted into rod cluster control assemblies and placed at symmetrical locations in the core. Each such assembly contains a symmetrical grouping of four secondary source rods and between zero and twenty burnable poison rods. Locations in the assembly not The lack filled with a source or burnable poison rod contain a thimble plug.-

of sufficient clearance for these sourc only at the core locations which contai DUPLICATE DOCUMENT 271 299 Entire document previously entered into system under:

ANO No. of pages: