NRC MILK S AMPLING PROGRAM e

The NEC milk sampling program was initiated to provide the NRC staff with information relative to the current levels of radioiodine in milk on a prompt basis, such that plant activities / operations could be modified or expedited, if need be, to assure that the I-131 in milk remained at acceptable levels.

The NRC onsite priority for information was geared toward the rapid screening of environmental samples for unusual radioactivity levels, rather than the more deliberate, less timely, in-laboratory measurements.

j NRC milk samples were obtained from milk samples split by Met Ed on alternate days from four or five of the Met Ed routine milk sampling locations and from additional samples collected from time to time as deemed appropriate.

'Ihese samples were analy::ed using field techniques at the NRC Mobile Laboratory at the TMI site; providing "same day" results. Table I provfies the specifics regarding the milk sampling locations.

Analytical Procedure _:

Ten (10) milligrams of iodide carrier were added to a four liter aliquot of raw, unpreservea uf.1k.

The sample was then passed through a 40 cm> Dowex 1x8 (25-50 mesh) anion exchange column.

The colu=n was cinsed with water and counted in a fixed geometry for 50 minutes on a 3"x3" NaI (T1) detector or for 60 minutes on a Ge(Li) detector. Typical detection limits were 10 to 15 pCi 1-131/11ter milk, dependent on current background rates and count times.

The analytical results are tabulated in Table 3.

Quality Assurance:

The quality assurance program included the use of counts on simulated I-131 standards and background measurements with each set of data; comparison of the results with the licensee's data on split samples; intra-comparison of measurements of " positive" results betucen the NaI and Ge(Li) detection systems; and the participation in the counting of the EPA " spiked" sample crosschecks. The NRC results for the EPA cross checks samples are tabulated in Table 2.

Farminst Practices :

Cattle from the locations from which milk was sampled were on stored feed until May 5, 1979.

Beginning on April 28 cattle from 7B3 were on pasture.

Cattle from 14D1 and 2G1 were placed en pasture between May 5 and May 7.

Farm 431 cows are maintained on stored feed until May 15, 1979. Water supplies were from wells. During the pasture grazing season, the cattle also have access to streams and pond water.

Coats at farm 1B1 were allowed to graze throughout the interval of the TMI incident although stored feed supplement was provided.

253 127 f*

7 9 0 6 2 2cm Potsmn 7147

A

~

Milk Use:

With the exceptien of the milk from f arm 4B1, the milk was used' in processed food.

Milk from 4B1 was variously used, including fresh sales and for processed milk products.

Goat milk, when available, is sold for fresh use or cheese products.

5 m

f/, j )

I r.'.i.)

l 4

__J Table I NRC MILK SAMPLING LOCATIONS A

Azimuth Distance Type of Approx Number Location Description (decrees)

(miles)

Milk of Animals 431 1.1 miles ENE 62.5 1.1 cow 40 of site 7B3 1.6 miles SE 296 1.6 cow 30 o t'

<:i t e 14D1 2.7 miles w:M 297 2.7 cou 40 of site 2G1 2 milas NNE of 22.5 10.5 cow 30 Hershey 131 1.2 miles N of 5

1.2 goat 10 site Hoover Farm l '. 2 6.5 cow 85 Table II NRC RESULT 3 0F EPA MILK CROSS CHECK SAMPLES Detector p ei I-131/1 NaI(TIT 21 i 3 Ge(Li) 22 1 2 Results corrected to 2000 hr on 4/28/79 a.d based on 3.79 liter sample received.

EPA reported "true" value as of 2000 hr on 4/28 /79 wa s 23.1 pe i/1.

\\

o2 [ ~~'j ).. '} L. <)-

)

1

Table IIIs l

NRC MILK ANALYTICAL RESULTS Location 4B1,1.1 miles at 62.5 Ccw Milk Sample Date Milkings Analytical Method I-131 (oci/1) 4 12

  • 4/3/79 am e

a/ (1)

< 90 x4/3/79 am 4/4//9 am c

< 5 b/ (1)

< 30 4/7/79 am 4/7/79 am c

< 5 b/ (c)

< 30 4/11/79 am 4/11/79 am c

< 3 4/15/79 am b/ (1) et 30

  • 4/17/79 am b/(1)

< 30

  • 4/17/79 am b/(2)

-< 9

  • 4/19/79 am b/ (2)

<(

7

  • 4/19/79 am b/(2)

<t l5 4/21/79 am b/ (2)

't 10 b/(2)

< 17 4/23/79 am 4/23/79 am b/(2)

< 10 4/29/79 am b/ (2)

% 11 5/1/79 am b/ (2)

< 12 5/3/79 am b/(2)

< 12 5/5/79 am b/(2)

< 11

  • 5/7/79 am b/(2)

< ll

  • 5/7/79_

am b/(2) s!10 5/9/79 am b/(2)

< ll b/(2)

< 12 5/11/79 am b/(2)

<11 5/13/79 am 5/15/79 am b/(2) 5 11 5/17/79 am b/(2) 5 11 5/19/79 am b/(2) 5: 10 b/(2) 512 5/19/79 am 5/21/79 3 milkings, last at b/(2)

  • 012 am 3/21 5/23/79 am b/ (2)

T12 5/25/79 am b/ (2) 5til 5/27/79 am b/(2)

'Cll P

LJ) l:U

Table IIIb l

NRC MILK ANALYTICAL RESULTS Location 7B3, 1.6 miles at 296 cow milk Sample Date Milking Time.

Analytical Method I-131 (pci/1) 4/4/79 as c

<10

  • 4/7/79 am b/(1) 430
  • 4/7/79 am c

4 6

  • 4/11/79 am b/ (1)

< 30

  • 4/11/79 am c

4 6 4/17/79 am b/ (1)

< 30

  • 4/19/79 am b/(2)

( 15

  • 4/19/79 am b/(2)

<7 b/(2)

<11 4/21/79 am 4/23/79 am b/(2)

< 13 4/25/79 am b/(2)

< 11 4/27/79 am b/(2) 4 11 4/19/79 am b/(2) 4 11 5/1/79 am b/(2) 4 12 5/3/79 am b/(2) 4 12 5/5/79 am b/(2)

< 12 5/7/79 am b/(2)

<11 5/9/79 am b/(2)

< 11 5/11/79 3 milkings to am on 5/11 b/ (2)

< 12 5/13/79 pa b/(2)

< 11 b/(2)

< 12 5/15/79 am 5/17/79 am b/(2)

< 11 5/19/79 am b / (2)

< 12 5/21/79 am b/(2)

< 12 5/23/79 a=

b/(2) 4 12 5/25/79 3 milkings, last at am b/ (2)

< 11 on 5/25 5/27/79 3 milkings, last at am b/(2) 4 11 on 5/27

%3

\\ 1 \\

t. s l

I Table IIIc NRC MILK ANALYTICAL RESULTS Location 14D1, 2.7 miles @297, Cow Milk

  • Sample Time Milking' Time Analytical Method I-131 (pCi/1)
  • 4/11/79 (4 milkings to am 4/11) b/(1) c30

~

  • 4/11/79 am c

4 3

  • 4/17/79 am b/(1)

< 30

  • 4/17/79 am b/(2)

<7 4/18/79 am b/(2)

< 7 4/19/79 pm b/(2) 4 15

  • 4/21/79 (4 milkings to am 4/211 b/(2)

( 10

  • 4/21/79

(

"')

b/(2)

< 12 4/23/79 (4 milkings to am 4/23) b/(2)

< 17 4/25/79 am b/(2)

< 12 4/26/79 pm b/(2) 4 12 4/28/79 pm b/(2) 4 12 5/1/79 am b/(2)

< 12 5/2/79 pm b/(2)

< 13 5/5/79 as b/(2) c 11 5/7/79 am b/(2)

< 11 5/9/79 am b/(2)

< 11 5/11/79 am b/(2) 4 11 5/12/79 pm b/(2)

<.12 5/17/79 am b/(2)

<s 12 5/18/79 pm b/(2)

( 11 b/(2)

< 12 5/21/79 am 5/22/79 pm b/(2)

< 12 5/24/79 pa b/(2)

< 12 5/26/79 pm b/(2) 4 12 i

L) ( )

1c J

e l

4 1

)

Table IIId NRC MILK ANALYrICAL RESULTS_

Location 2G1, 10.5 miles 022.5 Cow Milk Sample Date Milking Time Analytical Method I-131 (oci/1)

  • 4/11/79 am b/(1)

< 30

  • 4/11/79 am c

% 3 4/13/79 am a / (1)

< 90

  • 4/17/79 am b/ (1)

< 30 24/17/79 am b/(2)

<9

< 7

  • 4/19/79 am b/(2)
  • 4/19/79 am b / (.)

< 14 4/21/79 am b/ (2)

< 11 4/23/79 am b/(2)

< 17 4/25/79 am b/(2)

< 11 4/27/79 am b/ (2) t 'l 4/29/79 am b/ (2)

% 11 5/1/79 am b/(2)

< 12 b/ (2) 5 12 5/3/79 am b/(2)

% 12 5/5/79 am 5/7/79 am b/(2)

< 11 b/(2)

< 11 5/9/79 am b/(2)

% 12 5/11/79 a,

5/13/79 pm b/ (2)

% 11 5/15/79 am b/(2)

< 12 5/17/79 am b/(2)

< 12 5/19/79 am b/ (2)

% 12 5/21/79 am b/(2)

< 12 5/23/79 am b/ (2)

  • 12 5/25/79 am b/(2)

< 11 5/27/79 am b/(2)

< 11

\\

'5 r

'j ), 3

\\:-

-..-l

Table IIIe NRC MILK ANALYTICAL RESULTS l

Location IB 1, 1.2 miles @ 5, Coats Milk Coats farm

~

Samp1 r cate Milking Time Analytical Method I-131(pCi/1) j i

4/29/79 am b/(2) 36 4

    • 4/29/79 am b/(2) 28 1 4 5/5/79 am b/(2) 24 1 3
    • 5/5/79 am b/(2) 4.11
  • 5/8/79 pm b/(2) 8.5 1 1.9 5/8/79 pm b/(1) 12.2 t 1.8 5/13/?9 am b/(2) 4 11 5/16/79 am b/(2)

< 11 5/20/79 am b/(2)

< 10 5/23/79 b/(2)

< 12 Si27/79 pm b/(2)

< 11

')D

\\"l g

1

Table IIIf NRC MILK ANALYTICAL RESULTS Location - Hoover Farm, 6.5 mile:: at 142 Cows Milk Sample Date Milking Time Analvtical Method I-131 oci/1 I'

5/20/79 p.m.

b/(2)

< 11 m

I t +,

d

~}

p.-

U

/JJ

\\

')

e a

r-i

d FOO'INOTES TO TABLE III a

- sample analyzed in 500 ml Marinelli b

- 3.79 1 sauple put through resin column c

- sample also analyzed of State of Maryland for NRC using Ge(Li) 5

~

(1) - analyzed on NRC mobile lab Ce(Li)

(2) - analyzed on NRC mobile lab NaI(Tl)

- indicates same sample was reanalyzed

    • - fluid from 5/5/79 sample af ter passing through resin d

- 1 sigma counting uncertainty e