Text
TMI DOCUMENTS f -d!g DOCUMENT NO:
]
0F DOCUMENT PROV D ED BY COFf MADE ON %,
METROPOLITMi EDISON COMPANY.
M -
'Jilda R. Mullinix, NRC
,/
-4 C y)
(1
~'
178 165 r.
7906130n.bo-
,r '
~r
's
MM7f7CNV 195o 1 C01UR0LLED COPP"'"'"6 v-DO itTi~ REMOVE THREE MILE ISLAND NUCLE AR STATION STATION CHEMISTRY PROCEDURE 1950.1 DETERMINATION OF GROSS ALPHA Table of Effective Pages Page Date Revision Pagc Date Revision Page Cate R evision 1.0 11/10/76 1
26.0 51.0 2.0 27.0 52.0 3.0 28.0 53.0 4.0 29.0 54.0 5.0 30.0 55.0 6.0 31.0 56.0 7.0 32.0 57.0 3.0 33.0 58.0 9.0 34.0 59.0 10.0 35.0 60.0 11.0 36.0 61.0 12.0 37.0 62.0 13.0 38.0 63.0 14.0 39.0 64.0 15.0 40.0 65.0 16.0 41.0 66.0
_ 17.0
. _ 4 2.0
_ 67.0 _
18.0 43.0 68.0 19.0 44.0 69.C 20.0 45.0 70.0 21.0 46.0 71.0 22.0 47.0 72.0 23.0 48.0 73.0 24.0 49.0 74.0 25.0 50.0 75.0 Unit 1 Staff Recer.1 nd *A
- roval Unit 2 Staff Recom 2nds A roval A pproval
/
Date Approval k
Date Cogniarh DeM. deai Co.3niza/t 6d'/Hejd Unit 1 PORC Pecommends Approval Unit PORC Recommends Approval MVn-Z~
Date //-l-7G bM*Tu::Gu aS Date #~ ~ ' E-ggChairman of PORC Chairman of PORC PORC comments of inc!uded PORC comments of included (date)
(date)
T 3V D a t e --
By Oste AG apprcval Y$Ef W}/f'/'
)) ' /g l/ / StatigSuperintenden'/
/ 55^
' 7*
Unit Su;:ermtendent f
178 16e
1950.1 Revision I 11/10/76 STATION CHEMISTRY PROCEDURE NO. 1950.1 l
Determination of Gross Alpha 1.0 SU.*: MARY This procedure is to be used for a quick screening of a sample to detect alpha. Where an accurate activity is desired use SCP 1962.
Gross alpha measurements are made on samples from the Reactor Coolant System and, under certain circumstances, on liquids prior to release to the environment.
Since alpha particles are readily absorbed by even icw density materials, self-absorption should be minimized by keeping the layer of samole as thin as possible.
2.0 APP 2RATUS 2.1 See 1950 3.0 _ REAGENTS
~- -
3.1
.;one 4.0 _PRCCEDURE a.1 Pipet an appropriate volume of the sample into a planchet.
if the pipet is designated TC, rinse it twice with demin. water into the planchet.
4.2 Ory under an infra-red lamp, cool, and count.
4.3 Calculate the activity and s'andard deviation using stept 4.6 and 4.7 from Procedure No. 1950.
5.0 REFERENCES
5.1 Radiological Health Hand 3cok.
5.3 TMI HPP 1703,1706,1712 and 1712.
1 l.0 l
~
T/8 fff 4
5 0
..... k