ML19224A644

From kanterella
Jump to navigation Jump to search
Requests Addl Info Re Analysis of Cooling Tower & Thermal Discharge.Amend to Environ Rept Containing Responses to Encl Questions Should Be Submitted by 790615 in Order to Continue Environ Review
ML19224A644
Person / Time
Site: New Haven
Issue date: 04/23/1979
From: Regan W
Office of Nuclear Reactor Regulation
To: Kintigh A
NEW YORK STATE ELECTRIC & GAS CORP.
References
NUDOCS 7905070316
Download: ML19224A644 (4)


Text

[

  1. 1[

(4, UNITED STATES 4

NUCLEAR REGULATORY COMMISSION f

]

WASHINGTON, D. C. 20555 Y&' ~ vf i

\\, ".!' /

APR 2 31979

+..

Docket Nos. STN 50-596 STN 50-597 Mr. A. E. Kintigh Vice President-Generation New York State Electric & Gas Corporation 4500 Vestal Parkway East Binghamton, New York 13902

Dear Mr. Kintigh:

As a result of our continuing environmental review of the application for the proposed New Haven Nuclear Station, Unit Nos. 1 and 2, we have found additicaal areas where information is required. The enclosed questions were developed as a result of our review of your analysis of the cooling tower and thermal discharges from the Station.

It would be helpful if these specific questions could be addressed at the initial meeting at the time of the site visit on May 7,1979.. In addition, it is felt that a short presentation on each of the alternative sites at this initial meeting would be appropriate. This would help the NRC reviewers in placing the New Haven site in proper perspective. A more detailed agenda for the sitt visit, beginning May 7,1979, is now being worked out.in conjunction with the NYSEG staff and the New York State Public Service Commi:sion. This agenda will be sent to you as soon as it is fully developee.

It is suggested that responses to these questicns, and any others still pr ng, be formally addressed in an amendment to the Environmental Report af., the concl" ' a of the site visit. This will allow you to include responses to an. questions that may be generated during the site visit in your next amendment to the Environmental Report.

If it is necessary to obtain further clarification of this request, please contact Donald E. Sells, the Environmental Project Manager (301) 492-8445.

a uosD103a\\

c HJf I

t

Mr. A. E. Kintigh APR 2 319f3 The anendment to your Environmental Report containing the responses to these questions and any that may be developed during the site visit should be. submitted by June 15, 1979 in order for us to continue our environmental review.

Sincerely,

,\\

i

/

3 Wm.j

.x 2w.

H. Regan, Jr., Chief L F Environmental Projects Branch 2 s

Division of Site Safety and Environmental Analysis

Enclosure:

As stated 452 126

Mr. A. E. Kintigh APR 2 3 59 cc:

Roderick Schutt, Esq.

Paul Vaninski, PH.D.

!!uber, Magill, Lawrence & Farrell Vice President 99 Park Avenue Mexico Academy and f:ew York, New York 10016 Central School Mexico, New York 13114 Andrew W. Wofford, Vice President Long Island Lighting Compary Michael Flynn, Esq.

175 Old Country Road Robert Gray, Esq.

Hicksville, New York 11801 Craig Indyke, Esq.

State of New York Department Edward M. Barrett, Esq.

of Public Service General Counsel Empire State Plaza Long Island Lighting Company Albany, New York 12223 250 Old Country Road Mineola, New York 11501 David A. Engel Esq.

New York State Department E. J. Walsh, Jr., Esq.

.of Environmental Conservation General Attorney 50 Wolf Road Long Island Lighting Company Albany, New York 12233 250 Old Country Road Mineola, New York 11501 William Keeping, Supervisor Town of Gardiner Ms. Anne T. Curtin Gardiner, New York 12525 R. D. 1 Box 82A40 Dr. Stephen J. Egemeier, Valatie, New York 1218?

Chairman Environmental Management Council Stanley B. Klimberg, Esq.

300 Flatbush Avenue Acting Counsel Kingston, flew York 12401 New York State Energy Office 2 Rockefeller Plaza Peter D. G. Brown Albany, New York 12223 Chaiman of the Board Mid-Hudson Nuclear Opponents Ecology Action P. O. Box 666 c/o Mrs. Helen Daly New Poltz, New York 12561 W. River Road, R.D. 5 Oswego, New York 13126 John M. Cianci Office of Environmental Analysis Safe Energy for New Haven New. York State Department of c/o Mrs. Linda Clark Environmental Conservation Box 122, R.D. I 50 Wolf Road Mexico, New York 13114 Albany, New York 12233 Oswego County Farm Bureau Karl Abraham c/o Ms. Nancy K. Weber Thomas C. Elasser R.D. 3 Nuclear Regulatory Commission Mexico, tiew York 13114 Region I Office of Inspection & Enforce-ment 631 Park Avenue King of...Prussi4, 194C6 43d I

Environmental Report - Co.struction Permit Stage, New Haven Nuclear Station, Units 1 and 2 Request for Additional Information 1.

Provide the record high 1-hr wet bulb temperature and associated relative humidity at Syracuse for the period of record, 1955-1964. Also provide the average wet bulb temperatures used to determine the average discharge temperature.

Provide any updated data since 1964.

2.

Provide the cooling tower design curve, i.e. the cold water temperature as a function of wet bulb temperature and relative humidity.

3.

What is the exact distance between the centers of the natural draft cooling towers? How is plume merging treated in the plume rise and drift deposition models?

4.

What are the criteria for plume visibility used in the_ plume model?

5.

Present available validation for the plume, drift, fogging, and icing models.

6.

In which specific areas of calculation are cloud cover, visibility, ceiling height, and precipitation used?

7.

What is the reference for the table of values of p in Eq. (6.1-38) on page 6.1-59?

8.

What is the reason for using 3 cycles of concentration in drift calcu-lations instead of the more critical 6 cycles of concentration?