ML19224A198
| ML19224A198 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 08/24/1978 |
| From: | Durr J, Fasano A, Haverkamp D NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | |
| Shared Package | |
| ML19224A193 | List: |
| References | |
| 50-320-78-24, NUDOCS 7810190006 | |
| Download: ML19224A198 (1) | |
Text
.
2 4 AUG 1Fd APPENDIX A NOTICE OF VIOLATION Metropolitan Edison Company Docket No. 50-320 Based on the results of the NRC inspection conducted on July 18-21 and July 31 - August 3,1978, it appears that one of your activities was not conducted in full compliance with conditions of your Facility License No. OPR-73 as indicated below.
This item is an Infraction.
10 CFR 50, Appendix B, Criterion V, states, in part:
" Activities affecting quality shall be prescribed by... procedures...and shall be accomplished in accordance with these... procedures...."
The accepted Operational Quality Assurance Program (FSAR Section 17.1.5.1) states, in part:
"The Met-Ed Quality Assurance Plan...contains the J
.equirements that activities affecting quality be documented by
/!
/
instruction, procedures...."
}
Mechanical Construction Procedure, MCP-2-2, Revision 12, specifies l
the requirement that weld rods, if not issued, shall be placed in j
holding / storage ovens and maintained at 250 F + 25'F.
Contrary to the above, on July 20, 1978, the holding / storage furnace containing the low hydrogen weld rods was found to be at an indicated temperature of 190 F.
l 2c5 l
1
.("
qs[olgoo06
-_.-~m-*
- '