U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN OFFICE OF NUCLEAR REACTOR REGULATION SECTICN 2.4.10 TLOODING PROTECTION REQUIREMENTS RtVIIW RESPONSIBIllTY
~
PriMry Hydroloqv "eteoroloqy Branch ( HM B )
Secondary - None I.
f'E AS OF REVIEW The locations and elevations of safety related facilitics and of structures and components required for protection of safety related f acilities are compared with the estimated static and dynamic effects of design basis flood conditions identified in safety analysis report (SAR) Section 2.4.2.2, to determine whether ficod ef fects need be considered in plant design or emergency procedures.
If flood protection is required, the type of flood protection (" hardened facilities",
sandbags, flood doors, bulkheads, etc.) is reviewed. Any emergency procedures required to implement ficod protection anrl warring times available for implementation thereof are reviewed, based on the flood conditions identified in other sections.
e If there ir, evidence of potential structural ef fects, the Structural Engineering Branc's (SEB) will be requested by HMB to ascertain whether these effects are properly considered 6.-
in the structural design bases for the plant; similarly, ASB will be requested by HMB to ascertain whether these ef fects are properly considered in the systems design bases for the plant. Guidance for determining whether these potential effects are considered properly is outlined in the appropriate SEB and ASB SRP sections.
II.
ACCEPTANCE CRITERIA The flood design basis for each facility must be ct>mparable with t e positions in Regula-tory Guide 1.59.
For construction permit (CP) reviews, the types ;f flood protection (discussed in Regulation Guide 1.102) proposed must be capable o protecting those safety-related structures, systems, and components identified f, Regulatory Guides 1.59 and 1.29.
For operating license (OL) reviews the specific designs of flood protectien measures are reviewed to assure the protection levels are adequate (including static and dynamic effects) for the controlling flond conditions and that any necessary technical specifica-tions are considered.
USNRC STANDARD REVIEW PLAN stendeed rev e pi.no e,e p,e,
.d f., th. go.cence of th. omce of N ci, R ctor R ogvienen eegef r.epen.. bio fe, the review of oppucatione to constrwet end operete neceeer pew $ plente These documente see mode sweelebie to the puhtec se part of the Comsniemen e polley to 6pform the nucleet indvetry and the generos publ64 el rogdefery procedures and poi 6csee Stenderd rewtow p4ene are not pubetitutee for reguletory gw6dee er the Cefemess%n e regulettene end coenpitence with these le not regelred The etendard tow 4ew plan secteene are beyed to Rewtesen 2 Of 39te Stenderd Formet and Centent of Safety Ane8ysie Reporte fea Nucteet Power Ptente Not est sectione of efie Stenderd Formet have e correcpond*ng rev$ew plan Pubsiehed stonderd cov6ew p4ene w*Ie be rowseed pertodkaary. se appropriete. to accommodete commenee and to reMeet new informetlen end espertence Cee ee of etendard review p6ene mov be obteened by request to the U S Neciese Regwiero v Commisesen. WeeMagton. D C. 20h66 Attent6en-Oo' ice of Nocteer Remetoe Regusation Coenmente and avggestione foe emprovement wel be co e6dered and showed esse be sent to the Ot'ic e of Nwcseer Reector Regulation 7907120013
Standard engineering practice in riositive flood control and shore protection, such as that developed by the Corps of Engineers, provides the basis for acceptance of methods to be employed for protection. Where sites are " hardened," that is, where emergency action is required, the time available t-implement emergency procedures must be estimated by analysis of the hydrologic design event.
The environmental conditions likely to prevail during all potential flooding events up to and including events uf the severity of the controlling event ne compared with the requirements for implementing flood emergency procedures, if the enviror, mental conditions likely are such that the procedures can be carried out, they will be considered acceptable. An appropriute item in the plant fechnical Specifications will be required in cases where emergency.ocedures are required to assure adequate flood protection.
" Hardened" flood protection (as discussed in Regulatory Guide 1.59, for facilities identified in Regulatory Guide 1.29) will be interpreted to mean
a most always in place."
III. REVIEW PROCEDURES The estimated design basis flood level is compared with the locatione and elevations of ifety-related components. The staff will independently determine 'rnm analyses of postulated individual hydrologic events whether flood protection is required, and if so, what protective levels (including static and dynamic effects) are applicable. These data are transmitted to Structural Engineering Branch (SEB) for determination of structural design criteria adequacy and to Auxiliary Systems Branch ( ASB) and Instrumentation and Con'rol Systems Branch (ICSB) for determination of safety system adequacy. For flood pr otection requiring emergency action, the design basis flood conditions, and other less
~
severe events, are reviewed to establish the minimum time available for implementatien of eme gency procedures. Physical parameters such as rate-of-rise (of river or lake levels),
as wel! as evaluation (based on experience and engineering judgment) of ficod warning networks, provide the staff with an independent estimate of available time.
These data are provided to ASB and IC5B fer their independent e g!uation of the time required to l
implement shutdown and flood protective measures.
For OL reviews, the design of flood protection measures is reviewed to assure compati-bility with the original design basis. For those p.onts for which shutdown (if required under Fequlatory Guide 1.59, Position 2) and installation of protective measures is required in the event of a major flood, the procedures for carrying out these measures are reviewed for compatibility of available and required times as established above.
The Technical Specifications must reference an emergency plan which allows for tte orderly installation of required flood protection.
The above reviews are performed only when applicable to the site or site region. Some items of review may be done on a generic basis.
Rev. 1 2.4.10-2 145 334
IV.
IVALUATION FINDINGS for CP reviews, the findings will consist of statements of flood design bases for safety-related facilities. If emergency procedures are required, the findings will i n<lic a t e staff conclusions that timo for implementation and methods of providing flood protection provide the necessary protection.
For Ol rev ie n the findings will indicate the flood protection measures provided for safely-related faci:: ties, and will ieJicate t he type of technical specifications n auired to assure that the pr otect ion will be in place.
If Rogulatory Guido 1.59, Position 2, is elected by the applicant, a statement describing lesser design bases will be included in the findings with the staf f's conc lusion of adequacy.
A sample CP-stage statement follows-
"The applicant states, and we concur, that the station is above the flood level of a Protnble Max imum F lood (PMI ), ei ther on the A River or the two intermittent streams crossing the site.
"fu.ther, the applicant has state 1 that the roofs of safety-related buildings will f.e constructed to safely dispose of, or store, local precipitation as severe as toe Probable M ximum Pr ec ipit ation (PMP).
Further, v conclude that the bases for 9
plant grading and drainage will be sufficient to prevent a threat to safety-related facilities by a localized PMP."
V.
Rif f RINCf 5 Other $RP sections in tha 2.4 series provide hydrologic design basis flood Icvels and environmental condition descriptions Reports of the Corps of Engineers, llnited States Geologic Survey, Bureau of Reclamation, National Oceanic and Atmospheri t Administration, and others will be used on an "as wailable" hasis to evaluate flood warning systems if applicable.
The references for acceptability of protection will be completed pro.jects of the Cor ps of Engineers and other federal, state, and local arjonc ies, and similar type, of proiection previously reviewed and found acceptable for other nuclear plants.
1.
Regulatory Guide 1./0, " Standard fermat and Contents of Safety Analysis Peports for Nuclear Power Plants "
2.
Regulatory Guido 1. ';9, " Design Bas is f lood f or Nuclear Power Plants. "
1 i T' 1' / F 3.
Regulatory Guide 1.29, " Seismic Design Classifiration."
i ItJ Jj 4.
Regulatory Guide 1.102, " flood Protection for Nuclear Power Plants."
2.4.10-3 I"v-I
5.
ANSI N170, " Standards for Determining Design Basis Flooding at Power Reactor Sites".
6.
Regulatory Guide 1.125, Physical Models for Design and Operation of Hydraulic Structures and Systems for Nuclear Power P ants."
7.
Regulatory Guic*e 1.127, " Inspection of Water-Control Structures Associated with Nuclear Power Plants."
I 'l 145 w.
Rev. 1 2.4.10-4