--v T4xc /L.w:

.. ~.

~ ~. -. - -

~

A ri1 10, 1979 p

Metropolitan Edison Company - Docket 50-320 Three MI'e Island Nuclear Station - Unit No. 2 Middletown, Pa.

Based on our evaluativo of the current status and operational require-ments of the Three Mile Island Nuclear Station - Unit Nos.

2, we hereby issue the following temporary change to the Technica' Speci-fication with regard to operability of the RB Emergency Cooling booster pumps.

Section 3.6.2.3.d of the Technical Specification shall be

r. hanged to read as follows:

3.6.2.3 d.

With all RB Emergency Cooling Bo7 ster pumps i nope rabl e,

operation may continue provided that RS temperatore is maintained less than 130 F and RB pressure is naintained no greater tnan -0.3 psig.

Fan-coil units shall be maintained operating during this time.

Mode applicability is 3 and 4

/

FOR TH7 U.S.

NUCLEA1 REG"LATORY CCKMISSION JK 7

ichard H. Vollmer Assistant Director for Systems and Frsjects Nuclear Reactor Regulation

[

f.

I30 UOJ

?905190 g56 e

e