Notice of Violation from Insp on 770808-19
ML19220B734
Person / Time
Site: Crane 
Issue date: 09/20/1977
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19220B716 List:
References
50-320-77-32, NUDOCS 7904270275
Download: ML19220B734 (1)


Text

i License fio. CPPR-66 4

SEP 21 1977 APPENDIX A j

i fl0TICE OF VIOLATION Based on the results of an tiRC Inspection conducted on August 8-19, 1977, it appears that certain of your activities were not conducted in full compliance with the conditions of your Facility License flo. CPPR-66 as indicated belcw.

This item is an Infraction.

10 CFR 50 Appendix B, Criterion X1, Test Control, states ' n part,

...all testing required to demonstrate structures system:

and components will perform satisfactorily in service is iden",ified and performed with written test procedures which incorporate the require-ments and acceptance 1-imits...."

The licensee's Test Manual, Test Instruction T1-9, Conduct of Test, section 3.3.2.6 states that, d... changes to test procedures are made by making an exception to it or by initiating a Test Change Notice (TCN)

Contrary to the above, during the period from August 8-19, while perfonning Hot Functional Testing the licensee failed to initiate test exceptions or TCN's for the following tests:

TP 600/5 Chemical Addition and Sampling Operational Test.

The licensee failed to initiate an exception or TCN when the prerequisite was not completed prior to performance of para-graph 9.7, Lithium Hydroxide Addition, and paragraph 9.8, the Verification of ESF Valve test sequence, as required by Hot Functional Test Control procedure TP 600/28; and, TP 600/28 HFT Centrol Procedure.

The licensee failed to initiate an exception or TCH for a change made to the chemistry requirements of the Reactor Coolant System (RCS) involving increasing the RCS Temperature to greater than 250 F with the Lithium requirements out of specifications.. The specification required LiOH >0.2 ppm, while the RCS analysis recorded 0.09 ppm LiOH.