Responds to NRC Ltr Re Violations Noted in IE Insp Rept 50-320/75-08.Corrective Actions:Approved Installation Procedure for Comprehensive Strength Test Submitted
ML19220B615
Person / Time
Site: Crane 
Issue date: 08/21/1975
From: Arnold R
Metropolitan Edison Co
To: O'Reilly J
NRC Office of Inspection & Enforcement (IE Region I)
Shared Package
ML19220B599 List:
References
GQL-1407, NUDOCS 7904270109
Download: ML19220B615 (4)


Text

.

9 i

i

/.

i.-__.

./

72..

n:.. ='

,/

w.

.., ~.u METROPOLITAN EDf SON COMPANY :.... a.u oc cu.rn.= nrur unun:a r=w m i

/

T OFFICE DOX 542 RE ACING, PENNsYLVANI A 19c02 TELEPHONE 215 - 3:3 :501 m

,-e nu J:..c.,

Ws o

GQL ILC7 Mr. J.

P. O'Reilly, Director Office of Inspection and Enforce = cat Region I United States Nuclear Regulatory Cc::ission 631 Park Avenuc King of Prussia, Pennsylvania 19406

Dear Mr. O'Reilly:

subject:

License N,.

CPPR-66 Inspection No. 75-08 Docket No. 50-320 This ic:ter is in :aspense t: the subject inspection repc : resulting frc Mr. A. Varela's inspectica en June 16-17, 25-26, 1975, and the findin;;s thereof.

Following is a listing of the deviations and responses to these deviations:

Deviation A Contrary Oc the c = 1:= cat in FSAR See:1cn 3.8.1.6.5 and Project Specifica:ica 2555-30 to construe:icu cf the Reac::: Euildinz in accordance vi:h ACI Standarc 3C1, cube strength testing to =casure the seven day ccepressive s:rength of the grou: used for the post tensioned tendcas was not perfor=ed.

Response A Specifica:ica 2555-30, paragraph 4.5, sta:es that "all groutin; operations shall c:nfor= :o the requiremen:s and rec==endations of PCI Recon ended Pras: ice for Greutir; cf ? st-Tensiened Pre-stressed Cencrete and ACI 301 excep: as = edified herein".

Para -

graph 4.0 recuires :ha: the cen::sc:or devel p a :endon ins:alla-tion and grou:ing procedure and submi: this precedure : the Engin-eer for appr val.

Since this approved :.nstallation preceduri: is a direct bypr:cuct of the specificati:n 1 is censidered :: be an extensica :o :ha: Opecifica:10n. Any ::difica:icn to either cf the docu=en:s not'ed abcve are appreved cnd accepted by :he engineer.

The a:::crel ins:allctice recedure : uiref : c:=presrice strenrih tes to be ac::npiiched c: 2d day: en :he gr:u- : rial

x for inicr-

=ation caly. Thia was d:ne and the results are c:: ached.

7904270.109

?. J. F. O' Reill; tesconce A (Cent'd' is not It shculd be noted tha: the cc:gressive strength of the greut a factor in the design and analysis of the tenden ins:cllction 1:.

Three Mile Island Unit 2.

Deviation ?

in FSAR Appendix C, Section 2C.1.4 to cen-Contrary to :he ec =1:: cat in accordence with the AS::I struction of the pos: tensiened sys c:

BLPV Code, See:1cn III, Divisica 2, tests to sensure the chloride and nitrate concentrctions of the grou: used for the pos: tensioned tendens were not perfor ed.

Resoonse 3 Referenec to the ASMI 31PV~ Cede,Section III, Divisica 2, was orig:-

nally intended to apply only to perfernance require:ents of the code rather than := cceplete and literal cc pliance with all aspects of This s:a:e ent vill be a= ended to be. = ore exclusive and the code.

definitive as fc110ws:

tensiening "The Stresstecl high efficiency S/H 54-5 EE post anchorage sys:c= cc plies with the performance require =ents established in sub-subarticles CC 2450 and CC 2460 of ' Stand-ard Code for Concrete Reactor Vessels and Centainnents (Section III, Division 2 of the ASMI Sciler and Pressure Ccde)'".

A=end:eut 32 to the ISAR due in Septc=ber 1975 vill incorpora:e this revised wording.

Sections of this cede other than these ref erenced above vill not be applicable.

Deviatien C Contrary to an accepted industry cede, ACI Cc==ittee 349, " Criteria Structures," a for Reinforced Concrete Nuclear Pcver Contain=en:

and test to =easure the alkalinity of spe:ial =a:erial recuire en:

tensiened tendon ducts was the vet grout =1x used to fill the post not perfor=ed.

Reseense C ACI Cc==ittee 349, Ti:le No. 69-2, " Criteria fer Reinforced Cencrete Nuclear Pcwcr Contain=en: Struccures" was not invoked or referenced in the design for Three Mile Island Uri: 2.

It should be noted that

. 277 On

c. J. P. O ' hc111;.

_3_

itecponse C (C e n t ' d 'i Portland cceen: 3rcut has historie:11y provided a high alkaline enviren=ent cc p :ible vi:h corrosion protection require =ents for Prestressin; steel.

Test perfor:ed by Sika Chc ical Ccrcoratien show that the p:4 of the wet mixed greut is approxt:ately'12,3, no coder currently in effect require p:4 =easurc ents of Portland ce=ent grout.

Very truly yours, I

/

R. C. AYhold Vice President irh 41e:

20.1.1 / 7.7.3.2.2 ee 9

0 e

9 9

80-278

Pirm,0U..

H TESTING LABOi,,.Tv.. i

" ~ " "

.......:..,3....

PITT!., b u R G H. P/..

Or der f.'u. I! W

.I, ;

,.......,..e.,c.,-................,...........,u.,,....

..........u.............

.....,e

..,..........m........~.....a.,..,,....

acy,,1 no.

e c,.,..,., f 7,/

REPQRT Date_5/C'^/ ei'd REPORT OF TEST OTJ COr.' CRETE CYLINDECO 6" DIN.1ETER BY 12 LENGTH l'nited I.r'rineers !. Cons' ',cter<. I:': ironr: ted hct. t:On:

\\I41"T:.t.n Ldn..::.\\E!..:t 1%r::

Tlirce '.ide !.'a nd t -

l'nited En; m:cr> h Cor.trect.ns. It.or:w:ted S 1~<d'~ C 5 ik*d L fuf/.'i' ////.'d.0

., cretc haen,cnt r 's/T&T d bir!? /~iO'fftib Vdt:7~id/c 'itude w -

N*~- $c >

.M'I3' Cor crete C! ass

_8d Co P.S. I.

{ff C'/ W ~L.

G.6Ui~

SIon.p l

g;, g Cmn't Aus Cate Act i To :' Lead j

Cor;. S t.

Inches 1

Temp.CF.

So. la.

Tested Dr.s 1

' b s.

i P.S !.

I f/hca n 'b/c.

I

4. O I // 20l 2R;

/4, ib -,

5 S, cc

'l 1

l l

l /5 e.-.;m 3 '7:5*c e

5 i

1 i

I i

i / d,. /< 73 3 3 So 9

i I

i Woi I S r 70 l

I I

I

'I flouUble-I

\\

d.o l //.,cc i I ZS;

/d Qeg

,53q c t

I I

l I

I l

/</./:'ce) 8 7c c, 1

I I

i i

l I /d c r.m

! ;5 :y e. r:

L_

J. _._.

l_

I l

! A'9 4

. 3 f S,a I

l

.T i

TT !

I l

i I

i i

i i

i I

I I

l l

I i

i I

I i

l i

I I

r I

i I

I I

I i

I i

i I

i I

l I

l l

I.

l l

1 I

I i

l i

I I

I I

I I

I I

1 I

i l

i i

)

I I

i i

i i

l

-1 I

i i

t

. 21' i ' ' s i i

i i

i s

t i

i i

i i

i i

l i

I I

i r

) 0.b'. C /

  • GUr c.s*1 b !',/1 dr# k/*//

thJ N l.

.r-sad A s,// & < < 4 9.. p, u,s.. x g no,<9

_./?5'.cc( /:u ii,i sN/'

/

J/

//'

i

//MC d LYf.bYer[

PITTS'ibnGH TESTING !.6r.CG ATORY x

,x /

.i.(.4 <f.,./,.- / '. /....,1 m,~ ~ _ w z*t}"I 5 -_.,.

.- -