se Oc 05 c r 10, 1973 Dociet No.

3.m

".ctropolitan Edison Conpany A ~ i:

Mr. John G.

v. iller Vice Presihnt P. O. 30:e 541

.9a adin3, ?cansylvania 19o33 Gentle:nen:

The Regulatory staff has had the subject of anticipated transients without scran (ATWS) in water-cooled reactor power plants under study for sone cine. This matter was cited in the Advisory Cccmittee on Reactor Safeguards (ACRS) report and/or in the staff safety evaluation report on your application for a construction permit.

The staff has complaced its review of !.745 and has conrinAed that nessures should be taken to improve nuclear plant designs in this regard. Details of the staff review and conclusions and of the steps that should be taken to deal with ATJS are given in the staff

" Technical Raport on Anticipatad Transients Without Scra:a for Water-Coolad Power Reactors," Septenber 1973, a copy of which is enclosed for your infor=ation. The improvement measures acceptable to the staff are outlined in the staff position on ATVS, Appendi:t A, of the enclosed report in descending order of preference; that is, the "A" sections of the staff position describe tha ultimate objective. For those facilities for which the imposition of the requirements of the "A" sections is not practical, the staff vill accept the siternate approaches of the "B" or "C" sections subject to the linitations specified in the staff position. The rationale and bases for this approach are given in the enclosed report.

Acceptable nessures that should be taken for the subject facility (s) are either those in the "A" or the "B" sections of the staff position.

If there is reasonable assurance that the provisions of the "A" sections can be net satisfactorily on a schedule consistent with that of the subject facility (s), you need not analyze the consequences of ATVS.

You must, however, provide sufficient analyses and discussion to justify cmcr >

x

.. 7,y..

l sunaw >

Datt > I

! k.!..k....

~ ~. &r' " --

2... O f.

,,,, u c.,,.

,, o ucw ~

i30424C / 527

)

ao

. "atremolitan :dicen Cc=eany Cetob e r 10, 1273 your position and a ecenitmant that you will r. set th.s provisions of the "A" sections or revert to the provisions of the "3" aections if required by the staff. You should advise the staff by no later than January 1, 1974, of the approach you intend to take and submit a detailed report addressing fully, either the "A" or "3" sections of the staff position by October 1,1974, as an M'="t to the Safety Analysis Raport or with your application for an operating licansa, whichever is later.

The staff is prepared to discuss this natter with you at a mutually agreeable ti=a.

Sincerely, A. Giambusso Deputy Director for Reactor Projects Directorate of Licensing

Enclosure:

Technical Report on AT'JS for Water-coolad Power Reacters, Septe:aber 1973 cc:

Ganaral Public Utilities Sarvica Corecratica A1T.l :

"r.

R. W. Heward Project F.anager 260 Gerry Hill Fead Parsippany, :?cv Jersey 07054 General Public Utilites Service Cor >crarten AT21:

Ir. T. A. Cri== ins, Jr.

Safeey and Licensing :'.anager 260 Qerry E111 Road Parsi;:pany, :iew Jersey 07054 Gerald Darnof f, Esquire SIsaw, Pittman, Potts, Trc%b ridge and ' adden 310 17 th S tree t, :TJ

  • iasisin g t en, 'J. C. 20005 I

I l

cmer > [....

i i

...... p..

t i

l l

$ URN AME >

i OAN b.

L,')

((,* jy For.n Arc.u s aev 1.m AECM mo a i-a-e na s-i uses

a O

e -.;.,,...

a............

rc

.-w t e r.,1 O. n 3 us v.

a,,.2

4.1, sau..-.

p'.i..

7.

O..g 3.;.4

.3 R.

C.

3@.* c un g J. '4eadrie A.

.Annese

3. N. RieC'427 wu
o. n.

3 M.

Service 2.

Eisenhut Project Manas'er Karl "niel R.

R. 'iaccary

'i. S telic R.

L. Tedesco H.

2.

Deaten AC?S (16)

R. S. Scyd A.

Gia:b uss o

.e n

,at

.se e.U

=

h CCC U.)

e e, g f

_