ML19220A596

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 770321-24
ML19220A596
Person / Time
Site: Crane 
Issue date: 04/25/1977
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19220A592 List:
References
50-320-77-11, NUDOCS 7904230150
Download: ML19220A596 (1)


Text

-

License No. CPPA-66 APPENDIX A NOTICE OF VIOLATICN Based on the results of an NRC inspection conducted on March 21-24, 1977, it appears that one of your activities was not conducted in full ce=pliance with conditions of your NRC Facility License No. CPPR-66 as indicated below. This ites is an infraction.

A.

10 CFR 50, Appendix 3, Criterion X states, in part, "A progra=

for the inspection of activities affecting quality shall be executed... to verify conformance with the documented instructions, procedures, and drawings for accomplishing the j

activity...."

The licensee's FSAR, paragraph 17.1.10.4 s ts.t e s,

in part, " Activities affecting quality are verified by inspections....

Their (UE&C) activities are conducted in accordance with written procedures, instructions, and checklist...."

UE&C procedure ECP-9-2 requires verification for low voltage penetrations that the " Insulation resistance between conductors and between conductors and metal f ramework or headerplate shall be greater than 108 ohms a t ro em t emperature...."

Contrary to the above, on June 10, 11, and 28, 1976, electrical penetrations R516, R414, and R520 were accepted by QC personnel t

although the resistance tests between conductors had not been performed.

S 7904eao e crito t

f W

w

-