._
{irg-'
Nuclear Engineering Company:Inc.'
u,,3 92co SHELBYVILLE ROAD. SutTC 526 P. o. Box 7246 D1 l
LoulSVILLC. K ENTUCK Y 4o207 P.~.ON E (5o2) 426 -7160-
.... Il 0 7 u,-
December 21, 1979
'_h!.
- ; CEG.
b.".
1W Mr. Charles E. MacDonald, Chief
"' ' SECTION Transportation Certification Branch i
Division of Fuel Cycle & Materials Safety U. S. Nuclear Regulatory Commission Washington, DC 20555 Docket 71-6144
Dear Mr. MacDonald:
Enclosed are seven copies of each of the following documents as 3
referenced in my November 27, 1979 letter to you:
1.
Bill of Material No. 6901-002C 2.
An Engineering Evaluation of the Structural Ability of Kenasco Corporation's Radioactive Material Waste Container, Drawing No. 6901-002B USA DOT 7A, Type B, to meet the Special Tests of the Department of Transportation's Rules and Regulations Paragraph 173.398 3.
Drawing No. 6901-002B - DOT Type B Radioactive Waste Container 4.
A TWX from Garlock stating that the Model 23 Split Klosure is an improved design replacing the previous Model 21 Split Klozure 5.
Gasket-Seal Replacement Schedule Nuclear Engineering Company, Inc., as an owner and principle licensee of the B-2 cask, hereby recuests that the Certificate of Compliance be renewed.
Sincerely, NUCLEAR ENGINEERING COMPANY, INC.
4,(smas,[/Ar/d.
T ' T 3p Thomas S.
Baer
--f
'.U i
/ddb 2/[ -
Vice President
- 846 TSB/bt Enclosures 1765 209
'r. "n g 8001180 0,
4 GASKET-SEAL REPLACEMENT SCHEDULE The lip-type gaskets which form the seal for the container must be in the best possible condition to provide the desired containment.
The following criteria will be used to deter-mine the gasket replacement schedule:
I.
Inner and Outer Gasket Condition - Two lip-type gaskets form the seal for the container.
Both are located on the lid of the container and shall be inspected for signs of damage and/or deterioration.
Any indications of damage shall require replacement of the affected gasket prior to customer usage.
II.
The gaskets and seals will be replaced annually or sooner as required by criteria I.
1765 210
.e-
KENASCO CORI> ORATION Drawing No. 6'101 -002C 131LL OF AIATERIAL f
~
l'a rt l
- .o.
No.
.\\la te rial
.\\ lea s u remen ts Rema rk s
_ _ p,j r. ij i
e i
! A 1" plate 91" x 142" No Bevel i
D 1,.
.,_2 i
8 t" x 132" No Bevel 1
I 3
"~
- C 81" x 132" Bevel 4 ed es 40" 1/8" landi I:
all bevels trom tne same siue i
D 77" x 128" No Bevel
!1
[
E l 79" x 130" No Bevel I
j l
F 31" x 140" Bevel one 140" edge & two 51" 2
edges from the same side 40 1/8" landinc l
,G 39" x 128" 2
H 38" x 126" Bevel one 126" edge 40 1/8" 2
landing, bevel other 126" edge 60 1/2" landinc ocoosite side I
31" x 91" Bevel one 91" edge 40 1/8"landinc
- 2 J
39" x 79" Bevel one 79" edge 40 1/8" landing, 2
bevel other 79" edge 60 1/2" landing cocosite side K
38" x 75" Bevel one 75" edge 40 1/8" landing 2
[
bevel other 75" edge 60 1/2" i
i landing opposite side l
1 L i
1 " x 3 " fla t 91" Bevel one 91" edge 40 1/8" landine 12 3
hi 1" x 3" flat 136" Bevel one 136" edge 40 1/8" landing l2 bevel both ends occ_ osite side i
N 1" R 8" x 81" Bevel one 81" edge 40 1/8" landing 2
bevel other 81" edge 4001/2" landing same side O
1" R 8" x 13 2" Bevel one 132" edge 40 1/8" landing {2 bevel other 132" edge 40 1/2" landine same side
\\
P
- 6. 625 O. D.
4-7/8"
\\
40 x 6. 065 I. D.
Y seamless tubing Q
8.625 O.D.
4-7/8" 16 x 8. 071 I. D.
seamless tubing R
3 /4" x 3 /4" 81" Chamfer after welding h place 2
S l
3 /4" x 3/4" 132" 2
T Liachine or 81" 2
l I
weld as
- showm 1765 211 r Q,_,
132" l 2 Ilevel one 128 erige an<l two 39" eclaes 400 1/8" lancling from the same sicle - bevel othe r 128" c<lce 600 172" landin : from opposite sido15UUFl
. MECIIANICS RESEARCH INC.
e p.,,,. _g.
.<... w.,~. y
. --.;ns g-ti -
g i
[.
t:
~
- c..
I.
(
1 STDYNECO LVL WU INF0 MASTER l-003984D354 12/20/79 I
TLX GARLOCK PAMY 01 PALMYRA NEW YORK DEC 90 79 TVX 81053534?S TDYNECO LVL ATTN 9ECKY CROPPER
- 5..
t
,MODEL 23 SPLIT KLOZURE IS AN IMPROVED DESIGN REPLACING
?
PREVIOUS MODEL 21 SPLIT KLOZURE
[.
.\\.
FJ POTTER GARLOCK IN
[
TLX 978291 GARLOCK PAMY 1016 EST TDYNECO LVL
,?
ame 9.
sE 1765 212 0