ML19211A581

From kanterella
Jump to navigation Jump to search

Discusses Review of Pipe Cracks in Chemical Vol Control Sys. Addition of Horizontal multi-stage Centrifugal Charging Pumps Will Not Cause Pressure Fluctuations.Effects from One Positive Displacement Auxiliary Charging Pump Possible
ML19211A581
Person / Time
Site: Maine Yankee
Issue date: 12/07/1979
From: Reid R
Office of Nuclear Reactor Regulation
To: Groce R
Maine Yankee
References
TAC-7845, NUDOCS 7912200150
Download: ML19211A581 (2)


Text

TE(Lf4

~

kB RIGO y

UNITED STATES j

NUCLEAR REGULATORY COMMISSION y)Q;.g(

s-,

WASHINGTON, D. C. 20555 E

December 7,1979 Docket No. 50-309 Mr. Robert H. Groce Licensing Engineer Maine Yankee Atomic Power Company 20 Turnpike Road Westboro, Massachusetts 01581

Dear Mr. Groce:

'On May 17,1978, we requested information concerning pipe cracks in the Chemical Volume Control System (CYCS) due to excessive charging pump vibrations with respect to the Maine Yankee nuclear facility. The requesi.ed infomation was provided in letters dated June 5,1978, February 14, 1979 and November 6, 1979.

Based upon our review of the information submitted, we have detemined that the operation of the three horizontal multi-stage centrifugal charging pumps will not cause pressure fluctuations. As a result, no fa'igue cracks in the CVCS piping are anticipated due to the pumps operation.

Maine Yankee does have one positive displacement auxiliary charging pump whose operation will cause pressure fluctuation.

The pump is operated about two hours per year in the range of 300 to 700 psig line pressure.

The design pressure for these lines exceeds 2500 psig.

Therefore, we do not anticipate fatigue failures in the piping system caused by the operating pressure fluctuation of this pump in its operating range.

Based on the above, we conclude that our concerns regarding pipe cracks in the CVCS due to vibration caused by charging pumps at the Paine Yankee nuclear facility have been satisfactorily resolved.

No further action on this issue will be required.

Sincerely, vL.l,.

bY-0 Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors cc: See next page 7

10 7012 3 0 hO

~

Yankee Atomic Electric Company CC:

E. W. Thurlow, President Mr. Robert R. Radcliffe Maine Yankee Atomic Power Company Office of Energy Resources 9 Green Street 55 Capitol Street Augusta, Maine 04330 Augusta, Maine 04330 Mr. Donald E. Vandenburgh Vice President - Engineering Yankee Atomic Electric Company 20 Turnpike Road Westboro, Massachusetts 01581 John A. Ritsher, Esquire Ropes and Gray 225 Franklin Street Boston, Massachusetts 02110 Mr. John M. R. Paterson Assistant Attorney General State of Maine Augusta, Maine 04330 Mr. Nicholas Barth Executive Director Sheepscot Valley Conservation Association, Inc.

P. O. Box 125 Alna, Maine 04535 Wiscasset Public Library Association 632 358 High Street Uiscasset, Maine 04578 Mrs. L. Patricia Doyle, President SAFE POWER FOR MAINE Post Office Box 774 Canden, Maine 04843 4

..