05000271/LER-1979-031-03, /03L-0:on 791110,during Refueling/Maint Outage, Hangers RCIC-H-82 & HPCI-HD-67B Removed from Svc.Removal Unnoticed During Review.Caused by Personnel Error.Hangers Returned to Svc

From kanterella
(Redirected from ML19211A297)
Jump to navigation Jump to search
/03L-0:on 791110,during Refueling/Maint Outage, Hangers RCIC-H-82 & HPCI-HD-67B Removed from Svc.Removal Unnoticed During Review.Caused by Personnel Error.Hangers Returned to Svc
ML19211A297
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 12/14/1979
From: Conway W
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19211A296 List:
References
LER-79-031-03L, LER-79-31-3L, NUDOCS 7912170329
Download: ML19211A297 (2)


LER-1979-031, /03L-0:on 791110,during Refueling/Maint Outage, Hangers RCIC-H-82 & HPCI-HD-67B Removed from Svc.Removal Unnoticed During Review.Caused by Personnel Error.Hangers Returned to Svc
Event date:
Report date:
2711979031R03 - NRC Website

text

\\

(7 77)

LICENSEE EVENT REPORT LER 79-31/3L CONTROL BLOCK: l l

l l

l l

l (PLEASE PRINT OR TYPE ALL REQUIREO INFORMATION) i e

o 1! lV T I V l Y l s l 1 l@l 0 l o l-l 0 l o 0 l 0 l 0 l-l0 l0 l@l4 1lil1l1l@l l

7 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE J0 57 CAT 58 CON'T 5ObRC l L hl 0 l 510101012 l 7 l1 @l11111 0 l 7 19 @ 1 12 l1 l 4 7 l9 l@

o 1

i 8

60 61 DOCKET NUMB ER 68 69 EVENT DATE 74 75 REPORT D ATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h 0

2 l l

See attached sheet g

, y 4

0 4

0 5

l 0

6 l

0 7

l l

0 8

80 7

8 9 E

CODE SU8CO E COMPONENT CODE SU8 Coo'E SU E

l Wl A lh Wh lC h l Sl Ul Pl 0l Rl Tlh l B lh lZ lh O

9 7

8 9

10 11 12 13 18 19 20 SEQU ENTI AL OCCURRENCE REPORT REVISION LER RO EVENT YE AR REPORT NO.

CODE TYPE NO.

h aE g l21 7 l9 l l-l0 3 l1 l l/l l 013 l Ll l-l l0l yu 22 23 24 26 27 28 29 30 31 32 T K N A ON ON PL NT MET HOURS S8 i FOR b 8.

SUPPLIE MANUFACTURER I l2 l0 l7 l@

lD l@lH l@

l Z l@

lZ lh l/ Ol 0l Ol 0l l Yl@

l N l@

l Al@

33 34 35 36 3

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 1

0 l See attached sheet i

,,,,j I

mi l

LLL3J

' I 8

7 8 9

r'2NIS S

sPOWER OTHER STATUS DIS O RY DISCOVERY DESCRIPTION NA l

l Blhl Review of Records l

M lElh 10l9l7l@l ACTIVITY CO TENT RELE ASED OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE NA NA l

d h [h]

1 6 7

8 9 to 11 44 45 80 PERSONNEL FXPOSURES NUMBER TYPE

DESCRIPTION

NA l

l0l0 0l@l2lhl 1

7

,ERSONNa'IN;UJIES

' S oeSCR,P1lO~e 1592 306 v

~UM-R l

10l0l01@l NA i

a 80 7

8 9 11 12 LOSS OF OR DAMAGE TO FACILITY TYPE D ESCRIPTION l

121@l NA i 9 80 7

8 9 to d@o sCRIPTION@

79121703cl7 PUBLiCliY NRC USE ONLY l

ll llIIIllIII I

l NA 2

O 68 69 80 ;

7 8 9 to 802-257-7711 i

W.

F. COnway PHONE:

NAME OF PREPARER

T VTVYS1 05000271 LER 79-31/3L EVENT DESCRIPTION AND PROBABLE CONSEQUENCES During the continuing effort to determine and insure the adequacy of the Seismic Class I hangers, as described in the NRC Bulletin 79-02, hangers SW-R-76, RCIC-H-82, and HPCI-HD-67B were removed from service during the post Fall Refueling / Maintenance Outage.

Prior to the sche-duled plant startup, all outstanding items were reviewed for their affect on system operability.

These three hangers went unnoticed during the review.

Tech. Spec. Section 3.6.I.1 requires that all seismic hangers be operable during power operation (based on interpretation as-sociated with RO 79-15). As allowed by Tech. Spec. Section 3.6.I.2, all hangers were repaired within the 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> time period.

There have been no similar occurrences reporte'd to the Commission.

CAUSE DESCRIPTION AND CORRECTIVE ACTION 3 The cause of this occurrence is the f ailure to recognize that a seismic restraint was not returned to service prior to plant startup.

The affected hangers were returned to service within the required 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> following the discovery. Appropriate personnel were reinstructed on the requirements for hanger operability and the necessity to perform more careful reviews of the documentation.

1592 307