Forwards LER 79-116/03L-0
Date released: 08/12/2019 Download: ML19210D113


LER 79-116/03L-0:on 791025,HPCI Steam Line Inboard Valve Failed to Isolate During Calibr & Testing.Caused by Conservative Setting of Torque Switch.Engineering Package Review Revealed That Higher Setting Should Be Used
ML19210D118
Person / Time
Site: Hatch 
Issue date: 11/14/1979
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19210D118 (2)
Forwards LER 79-116/03L-0
ML19210D112
Person / Time
Site: Hatch 
Issue date: 11/14/1979
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19210D112 (1)