ML19210D076

From kanterella
Jump to navigation Jump to search
Forwards Second Interim Deficiency Rept Re Tensile Anchor Capacities Lower than Assumed in Design Allowables
Date released: 08/12/2019 Download: ML19210D076


Second Interim Deficiency Rept:On 790507,general R&D Program Tests Revealed Cracking of heat-affected Zone of Welded Stud Anchors.Final Rept by 791221
ML19210D091
Person / Time
Site: Hartsville 
Issue date: 08/13/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19210D091 (1)
Forwards Second Interim Deficiency Rept Re Tensile Anchor Capacities Lower than Assumed in Design Allowables
ML19210D075
Person / Time
Site: Hartsville 
Issue date: 08/13/1979
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19210D075 (1)