Omaha Public Power District 1623 HARNEY a
OMAHA. NEBRASMA 66102 e TELEPHONE S36-4000 AREA CODE 402 November 6, 1979 Director of Nuclear Reactor Regulation ATTN:
Mr. Robert W. Reid, Chief Operating Reactors Branch No. 4 U. S. Nuclear Regulatory Commission Washington, D. C.
20555
Reference:
Docket No. 50-285 Telephone Conversation:
Mr. K. Morris, OPPD, and Mr. H. Shaw, NRC, October 1, 1979 Gentlemen:
In response to the subject telephone conversation, the follo"ing information is provided to indicate the status of charging pump modifi-cations:
(1) All accumulators are installed on charging pumps CH-1B and CH-1C, with damaging vibration and cavitation problems eliminated.
(2) An accumulator on suction piping of charging pump CH-1A has been installed. An accumulator on discharge piping vill be installed by the end of the next refueling out-age, scheduled to commence in mid-January, 1980.
Completion of modifications described in items (1) and (2) are expected to eliminate all vibration induced failures of charging pump discharge and suction piping.
Sincerely,
[ 1
~#
W. C. Jones Division Manager Production Operations WCJ/KJM/BJH:jmm cc: LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, N. W.
Washington, D. C.
20036 h001 s
u: '
355 do 7911200
?