Tech Spec Change Request 11 Amend 2 Supporting Licensee Request to Change DPR-50,App a Re Inaccessible Tendon Problems During Insp.Certificate of Svc Encl
ML19210A618
Person / Time
Site: Crane 
Issue date: 06/16/1975
From: Arnold R
METROPOLITAN EDISON CO.
To:
Shared Package
ML19210A616 List:
References
NUDOCS 7910300653
Download: ML19210A618 (5)


Text

,

METROPOLITAN EDISON COMPANY JERSEY CENTRAL POWER & LIGHT COMPANY AND P3NSYLVANIA ELECTRIC COMPANY THREE MILE ISLAND NUCLEAR STATION UNIT 1 Operating License No. DPR-50 Docket No. 50-289 Tec_hnical Specification Change Reg"est No. 11, Amendment 2 This Technical Specification Change Request is submitted in support of Licensee's request to change Appendix A to Operating License No. DPR-50 for Three Mile Island Nuclear Station Lhit 1.

As a part of this request, a proposed replacement page for Appendix A is also included.

IETROPOLITAN EDISON COMPANY By

[

Vice Presfdent-Generation Sworn and subscribed to me this /6 day of bw 1975 9

^ 0 kdZ$

Notary Public

r. : 2 ca.

E/ CJCA5a C.1 i4; lic;.4 1973

..,u 1492 177 7910s00 6 9 3

UNITED STATES OF NCRICA NUCLEAR REGULATORY CO3RIISSION IN THE MATTER OF DOCKET NO. 50-239 OPEPdTING LICENSE NO.- DPR-50 METECDOLITAN EDISON CC12ANY This is to certify that a copy of Technical Specification Change Request No.11, Amendment 2 to Appendix A of the Operating License for Ihree IEle Island Nuclear Station, Unit 1, dated June 16, 1975, and filed with the U.S.

Nuclear Regulatory Commission June 16, 1975, has this 16th day June,1975, been served on the chief executives of Londonderry Township, Dauphin County, Pennsylvania, and of Dauphin County, Pennsylvania, by deposit in the United States Mail, addressed as follows:

Mr. Weldon B. Arehart, Chaircan Mr. Charles P. Hoy, Chairman Board of Supervisors of Board of County Cornissioners of Londonderry Township Dauphin County R.D. #1, Geyers Church Road Dauphin County Courthouse Middletown, Pennsylvania 17057 Harrisburg, Pennsylvania 17120 METROPOLITAN EDISON COMPANY By

/s/ R. C. Aracld Vice President-Generation

} kh.

Metropolitan Edison Company (Met-Ed)

Three Mile Island Nuclear Station Unit I (TMI-1)

Docket No. 50-289 Operating License No. DPR-50 Technical Specification Change Request No.11, Amendment 2 Licensee requests that the enclosed page h-36a be substituted for the existing page h-36a of Technical Specification Change Request 11.

Reason for Chance Request While beginning the first-year Tendon Surveillance Inspection, it was discovered that the Met-Ed testing equipment was too large to test several of the tendons selected for inspection. In an effort to ninimize 'any changes to the required program, a call was made to our vendor to determine the size of the vendor's testing equipment. It then appeared that the vendors equipment would fit all but one tendon, and it was requested that this tendon be changed in Amendment 1 to Change Pequest 11.

When the vendor actuall.' attempted to utilize his equipment on tendons H-2h-009 and H-2h-Oh7, it was found that they were not accessible for testing without extre=e, inappropriate acticns such as chipping of concrete. With the incorporation of this change, all tendons to be tested during the first inspection period have been verified to be accessible.

Preliminary review indicates that similar inaccessible tendon problems may exist for subsequent inspection periods. Changes regarding these tendons vill, however, be submitted at a later date.

Safety Analysis Justifying Change The proposed change involves substitution of two tendons in the first tendon surveillance inspection period. The tendons (H-2h-009 and H-24-018 and replacement tendons H-2h-021 and H-2h-Oh7) are estimated to have approxinately the same probability of corrosion and have a similar function in overa:.1 structural capabilities and properties of the structure. The substitution does not affect the randomness or the representative nature of the hoop tendons selected for inspection. Thererore, we have determined that the change does not involve an unreviewed safety question as, if implemented, it:

a.

vill not increase the probability or occurrence of consequences of an accident as analyzed in the TMI-l Final Safety Analysis Report (FSAR) b.

vill not increase the probability of an accident not described in the FSAR c.

vill not reduce the margin of safety defined as the basis for any Technical Specification.

1492 179

C.._ age Request No. 11 Amendment 2 TABLE 4.4-1 SELECTED TENDONS AND CORRESPONDING INSPECTION PERIODS 1.

Dome Tendons Inspection Period Tendons 1

D-101, D-116, D-201, D-220, D-301, D-316 2

D-102, D-117, D-202, D-219, D-302, D-317 3

D-103, D-ll8, D-203, D-218, D-303, D-318 4, 7, 10 D-116, D-220, D-316 5, 8 D-102, D-202, D-302 6, 9 D-118, D-218, D-318 2.

Vertical Wall Tendons Inspection Period Tendons 1

V-16, V-2 7, V-61, V-86, V-158 2

V-24, V-48, V-72, V-9 7, V-119 3

V-18, V-31, V-55, V-105, V-138 4, 7, 10 V-16, V-86, V-158 5, 8 V-24, V-48, V-119 6, 9 V-18, V-105, V-138 3.

Hoop Tendons Inspection Period Tendons 1

H-13-028, H-13-034, 7-13-046, H-24-021, H-24-047, l.

H-35-010, H-35-028, H-51-012, H-62-010 H-62-016 l

2 H-13-029, H-24-01C, H-24-019, H-35-Oll, H-35-029, H-46-020, H-46-024, H-51-010, H-51-034, H-62-011 3

H-24-Oll, H-24-0'8, H-35-009, H-46-018, H-46-022, H-2h-020, H-51-Oll, H-51-035, H-62-012, H-62-028 4, 7, 10 H-13-046, H-24 18, H-35-028 I

492 180 5, 8 H-46-024, H-51-03h, H-62-011 6, 9 H-24-020, H-51-Oll, H-51-035 4-36 a

UNITED 6TATES OF AMERICA NUCLEAR REGULATORY COMMISSION IN THE MATTER OF DOCKET NO. 50-289 OPERATING LICENSE NO. DPR-50 METROPOLITAN EDISON CDMPANY This is to certify that a copy of Technical Specification Change Request No.11, Amendment 2 to Appendix A or the Operating License for Three Mile Island Nuclear Station, Unit 1, dated June 16, 1975, and filed with the U.S.

Nuclear Regulatory Commission June 16, 1975, aas this 16th day of June,1975, been served on the chief executives of Londonderry Township, Dauphin County, Pennsylvania, and of Dauphin County, Pennsylvania, by deposit in the United States Mail, addressed as follows:

Mr. Weldon B. Arehart, Chairman Mr. Charles P. Hoy, Chairman

.30ard of Supervisors of Board of County Commissioners of Londonderry Township Dauphin County R.D. #1, Geyers Church Road Dauphin County Courthouse Middletown, Pennsylvania 17057 Harrisburg, Pennsylvania 17120 FETROPOLITAN EDISON COMPANY By

_t Vice Prd51 dent-Generation 1492 181