Tech Spec Change Request 28 Supporting Licensee Request to Change DPR-50,App a Re Accessibility of Tendons to Be Tested.Certificate of Svc Encl
ML19210A497
Person / Time
Site: Crane 
Issue date: 12/29/1975
From: Arnold R
METROPOLITAN EDISON CO.
To:
Shared Package
ML19210A495 List:
References
NUDOCS 7910300534
Download: ML19210A497 (7)


Text

,

METROPOLITAN EDISON COMPANY JERSEY CENTRAL POWER & LIGHT COMPANY AND PENNSYLVANIA ELICTRIC COMPANY THREE MILE ISLAND NUCLEAR STATION UNIT 1 Operating License No. DPR-50 Docket No. 50-289 Technical Specification Change Request No. 28 This Technical Specification Change Request is submitted in support of Licensee's request to change Appendix A to Operating License No. DPR-50 for Three Mile Island Nuclear Station Unit 1.

As a part of this request, proposed replacement pages for Appendix A are also included.

METROPOLITAN EDISON COMPANY By

[6bf Vice PresTdent-GeneE tion Sworn and subscribed to m' this day of

, 1975 nOT;.-': F uc.:c h., : c:: ;, - r:

9y Commi::i:.1 Empires Nu, 13, 1979 Notary Public 1491 1 U 381030cF3y

/

?

/

'5 4 f]M11 l

.-m

/

f METHOPOLil'AN EDISON COMPANY

,., o w, r u /

/

POST OFFICE BOX 542 PEADING, PENNSYLVANI A 19603 TELEPHONE 215 - 929-3601 December 29, 1975 GQL 0166 Director of Nuclear Reactor Regulation ATTN:

R. W. Reid, Director Operating-React or Branch No. 4 U.S. Nuclear ".egulatory Connission Washington, o.C.

20555

Dear Mr. Reid:

Three Mile Island Nuclear Station Unit 1 Docket No. 50-289 License No. DPR-50 Technical Specification Change Request No. 28 Attached are three signed originals and thirty-seven conformed copies of Technical Specification Change Request No. 28, requesting amendment to Appendix A of Operating License No. DPR.50.

As a part of this request, proposed replacement pages for Appendix A are also attachef, Also attached is one signed copy of a Certificate of Servi - of Technical Specification Change Reques t No. 28 to the chief executives of the township and county in which the facility is located.

Sincerely,

/s/ R. C. Arnold 9..

C. Arnold tice President RCA:CWS:cas File:

20.1.1 En closures : (1) Tuchnical Specification Change Request No. 28 and Appendix A Proposed Replacement Pages 4-36a and 4-36b.

(ii) Certificate of Service for Technical Specification Change Request No. 28 1491 154

METROPOLITAN EDISON COMPANY JERSEY CENTRAL POWER & LIGHT COMPANY AND PENNSYLVANIA ELECTRIC COMPANY THREE MILE ISLAND NUCLEAR STATION UNIT 1 Operating License No. DPR-50 Docket No. 50-289 Technical Specification Change Request No. 28 This Technical Specification Change Request is submitted in support of Licensee's request to change Appendix A to Operating License No. DPR-50 for Three Mile Island Nuclear Station Unit 1.

As a part of this request, proposed replacement pages for Appendix A are also included.

METROPOLITAN EDISON COMPANY

/s/ R. C. Arnold By Vice President-Generation Sworn and subscribed to me this 29tn day of Dece=ber

, 1975

/s/ Lawrence L. Lavfer Notary Public 1491 155

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION IN THE MATTER OF DOCKET NO. 50-289 OPERATING LICENSE NO. DPR-50 METROPOLITAN EDISON COMPANY This is to certify that a copy of Technical Specification Change Request No. 28 to Appendix A of the Operating License for Three Mile Island Nuclear Station, Unit 1, dated December 29, 1975, and filed with the U.S. Nuclear Regulatory Commission December 29, 1975, has this 29th day December,1975, been served on the chief executives of Londonderry Township, Dauphin County, Pennsylvania, and of Dauphin County, Pennsylvania, by deposit in the United States Mail, addressed as follows:

Mr. Weldon B. Arehart, Chairman Mr. Charles P. Hoy, Chaiman Board of Supervisors of Board of County Com=issioners of Londonderry Township Dauphin County R.D. #1, Ceyers Church Road Dauphin County Courthouse Middictown, Pennsylvania 17057 Harrisburg, Pennsylvania 17120 METROPOLITAN EDIS0N COMPANY

/s/ R. C. Arnold By Vice President-Generation 1491 156

Three Mile Island Iluelear Station Unit 1 (TMI-1)

Operating License IIo. DPR-50 Docket :io. 50-289 Technical Soecification Change Recuect :*o. 28 The licensee requests that the atteched pages 4-36a and 4-36b replace pages h-36a and h-36b of the existing Technical Specifications.

Reason for Proposed Change

'4hile conducting the Tendon Surveillance Program during June,1975 field personnel were exposed to excessively high te=peratures (approximately 135 F) while testing Hoop Tendon H-13-028.

Further, during the first inspection period it was noted that during the inspection of certain tendons personnel were required to work in the discharge path of the steam vents (these tendons were inspected during an outage). Also, other tendons designated for inspection by our present Technical Specifications are not accessible. The reason for this proposed change, therefore, is to change the Technical Specifications so that only accessible tendons are specified to be tested.

Safety Analysis Supporting Change The substitute tendons designated in this change request vill provide

(

approximately the same probability of corrosion, have similar structural functions and have been selected to provide a rando= but representative sa=pling. The substitute tendons do, therefore, satisfy the same requirements by which the original specified tendons had been selected, and for this reason this change request does not constitute an unreviewed safety question, and does not pose a threat to the health and safety of the public.

1491 157

(

TABLE h.h-1

(

SELECTED TEUDOU3 AUD CORRESPONDING INSPECTl")N PERIODS 1.

Dome Tendons Inspection Period Tendons i

D-101, D-11t, D-201, D-220, D-301, D-316 1

2 D-130, D-lh8, D-202, D-219, D-33h, D-3h8 3

D-431, D-lh7, D-203, D-218, D-336, D-3h6 h, 7, 10 D-132, D-220, D-3h7 5, 8 D-lh8, u-219, D-330 6, 9 D-131, D-218, D-346 2.

Vertical Wall Tendons Inspectien Period Tendons 1

V-16, V-27, V-61, V-86, V-158

{

2 V-2h, V h8, V-72, V-97, V-119 3

V-18, V-31, V-55, V-105, v-138 h, 7, 10 V-16, V-86, V-158 5, 8 V-2h, V h8, V-119 6, 9 V-18, V-105, V-138 3.

Hoop Tendons Inspection Period Tendons 1

H-13-028, H-13-03h, H-13-Oh6, H-2h-021, H-2k-OhT, H-35-010, H-35-028, H-51-012, H-62-010, H-62-016 2

H-62-Oh7, H-2h-Oh8, H-2h-019, H-35-011, H-35-029, H-h6-028, H-h6-02h, H-51-013, H-62-053, H-62-011 3

H-2h-Ok9, H-2h-028, H-35-017, H h6-030, H h6-032, H-2h-020, H-51-011, H-62-051. H-62-012, H-62-028 h, 7, 10 H-62-030, H-2h-C21, H-35-028 5, 8 H h6-02k, H-2h-Oh8, H-62-011 j

6, 9 H-2h-020, H-51-011, H-62-051 h-36a 1491 158

TABLE h.k-2

(

TE:CC:!S SELEC"ED FOR TENDON PHYSICAL CONDITION TEST TENDON LOCATIC:!

Insrection Period Dome Wall Hoon 1

D-301 V-27 H-35-010 2

D-202 V-119 H-62-Oh7 3

D-336 V-18 H k6-030 h

D-220 V-86 H-35-028 5

D-1L8 V-h8 H-k6-024 6

D-218 V-105 H-51-011 7

D-132 V-158 H-62-030 8

D-33h V-24 H-62-011 9

D-131 V-138 H-2h-020

(

10 D-3h7 V-16 H-2h-021 1491 159 L-36b