ML19210A182

From kanterella
Jump to navigation Jump to search
Abnormal Occurrence 50-289/75-28:on 750823,MS-V-13A Valve Turbine Drive Emergency Feed Pump Failed to Remain Open. Caused by Control Circuit Pressure Switch Failure,Due Possibly to High Ambient Temp
Date released: 08/12/2019 Download: ML19210A182


Abnormal Occurrence 75-28:on 750820,during Test of Turbine Drive Emergency Feed Pump,Associated Valve Failed to Remain Open.Caused by Failed Pressure Switch
ML19210A184
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 08/23/1975
From: Colitz J
METROPOLITAN EDISON CO.
To:
References
Download: ML19210A184 (2)
Abnormal Occurrence 50-289/75-28:on 750823,MS-V-13A Valve Turbine Drive Emergency Feed Pump Failed to Remain Open. Caused by Control Circuit Pressure Switch Failure,Due Possibly to High Ambient Temp
ML19210A181
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 09/02/1975
From: Arnold R
METROPOLITAN EDISON CO.
To:
References
Download: ML19210A181 (4)