  • I TENNESSEE VALLEY AUTHOR:TY sN ANOOGA TENNESSEE 37401 400 Chestnut Street Tower II 2: @dptember 28, 1979 g( - -

Mr. James P. O'Reilly, Director Office of Inspec:1on and Enforcement U.S. Nuclear Regslatery Commission Region II - Suita 3100 101 Marietta Street Atlanta, Ceorgia 30303

Dear Mr. O'Reilly:

SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - REACTOR VESSEL INSULF NCP CEB 79 THIRD INTERIM REPORT The subject deficiency was initially reported to NRC-OIE Inspector W. T. Cottle on June 5,1979, in accordance with 10 CFR 50.55(e).

Interim reports were submitted on July 3, 1979, and August We expect to submit our next report before fuel load.

31, 1979.

This nonconform-ance was reported for Watts Bar Nuclear Plant as NCR CEB 79-21.

Westinghouse has investigated the problem and provided a response to TVA.

TVA is continuing to review this response.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.

Very truly yours, TENNESSEE VALLEY AUTHORITY

~

l.

. M. Mills, P ger Nuclear Regulation and Safety Mr. Victce'Stello, Jr., Director cc:

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555

\\

1174 019 F

\\0 L/] T 7910190 S

An Equal Opportunity Employer OFFICIAL COPY