Forwards LER 79-007/01T-0
Date released: 08/11/2019 Download: ML19209D113


LER 79-007/01T-0:on 790929,main Steam Line B Isolation Valve Failed to Close During 20% Steam Flow,W/Unit Off Line.Caused Not Stated.Packing Was Loosened & Atwood Morrill Reverse Swing Check Valve Closed
ML19209D123
Person / Time
Site: Point Beach 
Issue date: 10/10/1979
From: Fay C
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19209D123 (2)
Forwards LER 79-007/01T-0
ML19209D112
Person / Time
Site: Point Beach 
Issue date: 10/10/1979
From: Fay C
WISCONSIN ELECTRIC POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19209D112 (1)