ML19209C130
| ML19209C130 | |
| Person / Time | |
|---|---|
| Site: | Wood River Junction |
| Issue date: | 08/24/1979 |
| From: | Martin W NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Bowers C UNC RECOVERY SYSTEMS, UNITED NUCLEAR CORP. (SUBS. OF UNC, INC.) |
| Shared Package | |
| ML19209C131 | List: |
| References | |
| NUDOCS 7910120010 | |
| Download: ML19209C130 (2) | |
Text
e ff4 pm reg UNITYD STATES f
- o NUCLEAR REGULATORY COMMLSslON 8
REGION I o
431 PARK AVENUE f
KING OF PRUS$1 A, PENNSYLVANIA 19406
\\*****/
AUG 2 41979 Docket No.70-820 United Nuclear Corporation ATTN: Mr. C. E. Bowers General Manager UNC Recovery Systems Wood River Junction, Rhode Island 02894 Gentlemen:
Subject:
Inspection 70-820/79-12 This refers to the inspection conducted by Mr. H. Zibulsky of this office on May 21-25, 1979 of activities authorized by NRC License No. SNM-777 and to the discussions of our findings held by Mr. Zibulsky with Mr. D. Daigler of your staff at the conclusion of the inspection.
Areas examined during this inspection are described in the Office of Inspection and Enforcement Inspection Report which is enclosed with this letter. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, measurements made by the inspector, and observations by the inspector.
Within the scope of this inspection, no items of noncompliance were observed.
In accordance with Section 2.790(d) of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, documentation of your control and accounting procedures for safeguarding special nuclear materials and your facility security procedures are exempt from disclosure; therefore, the enclosed inspectior report will not be placed in the Public Document Room and will receive limited distri-bution.
No reply to this letter is required; however, should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,
[
Walter G. Martin, Chief Safeguards Branch i,
J
Enclosure:
Office of Inspection and Enforcement Inspection Report Number 70-820/79-12 (Contains 2.790 Information) 791012oUO, b
United Nuclear Corporation 2
Mj 2 4 E.
cc w/rpt cover sheet only:
D. F. Cimnin, Manager, Nuclear and Industrial Safety D. M. Schultz, Manager, Compliance J
.