a nuou

/

'o UNITED STATES

! T ),, g,E,,g NUCLEAR REGULATORY COMMISSION REGION 111

/. r k' O 799 ROOSEVELT HOAD g

o,,,

8 oLEN ELLYN,ILL.NOIS 60137

~

g,.'....,o MEMORANDUM FOR: Those on Attached List FROM:

Helen Pappas, Chief, Administrative Branch

SUBJECT:

IE Circular No. 79-15 The attached IE Circular No. 79-15, titled " Bursting of iligh Pressure Hose and Malfunction of Relief Valve "0" Ring in Certain Self-Coutained Breathing Apparatus" was sent to the following licensees on August 8, 1979, for information:

American Electric Power Service Corporation Indiana and Michigan Power Company D. C. Cook 1, 2 (50-315, 50-316)

Commonwealth Edison Company Dresden 1, 2, 3 (50-10, 50-237, 50-249)

Quad-Cities 1, 2 (50-254, 50-265)

Zion 1, 2 (50-295, 50-304)

Consumers Power Company Big Rock Point (50-155)

Palisades (50-255)

Dairyland Power Cooperative LACBWR (50-409)

Iowa Electric Light & Power Company Duane Arnold (50-331)

Northern States Power Company Monticello (50-263)

Prairie Island 1, 2 (50-282, 50-306)

Toledo Edison Company Davis-Besse 1 (50-346)

Wisconsin Electric Power Company Point Beach 1, 2 (50-266, 50-301)

Wisconsin Public Service Corporation Kewaunee (50-305) 1131 227 7 910110 M7d>

0

Those cu Attached List AUG131979 Allied Chemical Corporation (SUB-526)

Battelle Memorial Institute (70-08)

Combustion Engineering, Inc.

(70-36)

General Electric Company (70-1308, 70-1309, 70-1220)

Goodyear Aerospace Corporation (70-01489)

Kerr-McGee Nuclear Corporation (70-925, 70-1193)

Purdue University (70-152)

Parkwell Laboratories (SNM-1347)

Amersham Searle (12-12836-01)

Picker Corporation (34-07225-09)

Minnesota Mining and Manufacturing Company (22-00057-06)

Monsanto Research Corporation (SNM-567)

Mallinckrodt Incorporated (24-04206-01) 113i 228

O D

. gg,,

Those on Attached List Abbott Laboratories (12-00621-03)

Cerac, Incorporated (STB-1027)

Sincerely, Helen Pappas, Chief Administrative Branch

Enclosures:

1.

IE Circular 79-15 2.

List of IE Circulars Issued in Last Six Months cc w/encls:

Central Files Reproduction Unit NRC 20b Local PDR NSIC TIC D. W. Kane, Sargent and Lundy 8

1

,g..,.

s I -,

t a

a h

f i

e 1

\\*

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 August 8, 1979 IE Circular No. 79-15 BURSTING OF HIGH PRESSURE HOSE AND MALFUNCTION OF RELIEF VALVE AND "O"-RING IN CERTAIN SELF-CONTAINED BREATHING APPARATUS Description of Circumstances:

The Nuclear Regulatory Commission (NRC) has been informed by mailgram (copy enclosed) from the National Institute of Occupational Safety and Health (NIOSH) of occurrences of bursting of the high-pressure hose assembly, and malfunction of the relief valve and of the "0"-Ring in the main line assembly of the SurvivAir Mark I self-contained breathing apparatus. Anyone of these failures would result in immediate loss of air supply to a user.

Licensees who use the SurvivAir Mark I SCBA should:

1.

Discontinue use of the apparatus until the units have been inspected by the manufacturer and all necessary repairs or replacements have been made.

2.

Cortact the manufacturer or supplier of the equipment for instptctions on arranging for inspection and repair.

No written response to this circular is required.

If you require additional information regarding this subject, please contact the office specified in the enclosed mailgram.

Enclosure:

Mailgram e

1131 230 g

M O

+.me e,

em

.q

..q_

. e -,

eye y

am e.pe me w asum e.

e e-.

=.. '

MAILGRAM RESPIRATOR USERS WARNING The National Institute for Occupational Safety and Health (NIOSH) advises workers to discontinue using the SurvivAir Mark I self-contained breathing apparatus until the units have been inspected by the manufacturer and all necessary repairs or replacements have been sede.

NIOSH has learned that the high pressure hose assembly installed by the manufacturer in some of these respirators is not the assembly originally tested and approved by NIOSH for this respirator.

In addition, reports from two fire departments indicate the following serious malfunctions have occurred recently during use:

1.

Bursting of the high pressure hose assembly (part no.

960627).

2.

Malfunction of the relief valve (part no. 912620).

3.

Malfunction of the 0-ring in the main line assembly (part no. 824193).

Any one of these failures would result in imediate loss o' 'tir supply to the user.

In response to a NIOSH request, SurvivAir has agreed to d.iscontinue sale and distribution of the respirators until all three problems are -

corrected. Nn NIOSH has detennined that the three problems have been corrected, you will be advised that the stop sales request has been with-drawn page 1 of 2

))

{

^

^

~

-.:..~..;--

()

')

MAILGRAu SurvivAir has also agreed to inspec't all units,in the field and make necessary repairs in accordance with a plan to be approved by NIOSH.

In the meantime, owners of SurvivAir Mark I self-contained breathing apparatus should contact the manufacturer or supplier for further instructions.

For further information contact NIOSH. Division of Safety Research. 944 Chestnut Ridge Road. Morgantown. West Virgina 26505. Telephone:

(304) 599-7595 113i 232

~

~

~

page 2 of 2

IE Circular No. 79-15 Enclosure August 8, 1979 Page 1 of 2 LISTING OF IE CIRCULARS ISSUED IN LAST SIX MONTHS Circular Subject Date of Issued to No.

Issue 79-03 Inadequate Guard Training-2/23/79 All Holders of Qualification and Falsified and applicants Training Records for Special Nuclear Material Licenses in Safeguards Group I 79- 04 Loose Locking Nut on 3/16/79 All Holders of Limitorque Valve Reactor OLs or cps Operators 79-05 Moisture Leakage In 3/20/79 All Holders of Stranded Wire Conductors Reactor OLs or cps 79-06 Failure to Use Syringe 4/19/79 All Holders of and Battle Shields in Medical Licensees Nuclear Medicine except teletherapy licensees 1,

79-07 Unexpected Speed Increase 5/2/79 All Holders of of Reactor Recirculation BWR OL's or CP's MG Set Resulted in Reactor Power Increase 79-08 Attempted Extortion - Low 5/18/79 All Fuel Facilities Enriched Uranium Licensed by NRC 79-09 Occurrences of Srlit or 6/22/79 All Materials Punctured Regulator Diaphragms Priority I, Fuel In Certain Self Contained Cycle and Operating Breathing Apparatus Reactor Licensees 79-10 Pipefittings Manufactured 6/26/79 All Power Reactor from Unacceptable Material Licensees with a CP and/or OL 79-11 Design / Construction 6/27/79 All Applicants Interface Problem for, and Holders of Power Reactor cps il3i 233

IE Circular No. 79-15 Enclosure August 8, 1979 Page 2 of 2 LISTING OF IE CIRCULARS ISSUED IN LAST SIX MONTHS Circular Subject Date of Issued to No.

Issued 79-12 Potential Disel Generator 6/28/79 All Power Reactors Turbocharger Problem Operating Facilities and all Utilities having a CP 79-13 Replacement of Diesel 7/10/79 All Power Reactor Fire Pump Starting Operating Facilities Contactors and all Utilf'ies having a CP 79-14 Unauthorized Procurement and 7/13/79 All Medical Licensees Distribution of IE-133 except Teletheraphy Medical Licensees and to all Radiopharmaceu-tical Suppliers L

113i 234

s,,

Addressees - Memorandum dated August 9,'1979 AUSl 3 $79 IE FILES AD/FFMSI/IE NMSS/FCSL (AD)

NMSS/FCWM (AD)

NMSS/FCMS (AD)

HPA/DTS CENTRAL FILES REPRO UNIT

. FDR NSIC 113i 235

T y

't Addressees - Memorandum dated August 9,'1979 AUSI 3 gi79 IE FI 1/4E NMSS/FCSL (AD)

NMSS/FCWM (AD)

NMSS/FCMS (AD)

MPA/DTS CENTRAL FILES REPRO UNIT-FDR NSIC 1131 236