TENNESSEE VALLEY AUTHORITY CH ATTANOOG A. TENN ESSEE 37401 400 Chestnut Street Tower II September 28, 1979 Mr. James P. O eilly, Director Office of Inspec on and Enforcement U.S. Nuclear Regu tory Cotaissica Region II - Suite 3 0 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - REACTOR VESSEL INSULATION -

NCR CEB 79 THIRD INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector W. T. Cottle on June 5, 1979, in accordance with 10 CFR 50.55(e).

Interim reports were submitted on July 3, 1979, and August 31, 1979.

We expect to submit our next report before fuel load. Thic nonconform-ance was reported for Watts Bar Nuclear Plant as NCR CES 79-21.

Westinghouse has investigated the problen and provided a response to TVA. TVA is continuing to review this rasponse.

If you have any questiont. concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.

Very truly yours, TENNESSEE VALLEY AUTHOLITY L. M. Mills, Manager Nuclear Regulation and Safety cc: Mr. Victor Stello, Jr., Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 6

% to 1\

t 7910100 3 3 6  ; ) 35 3c;7