ML19208D578

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-445/79-12 & 50-446/79-12 on 790412-0720.No Noncompliance Noted
ML19208D578
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/22/1979
From: Seidle W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Gary R
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
Shared Package
ML19208D579 List:
References
NUDOCS 7909280637
Download: ML19208D578 (2)


See also: IR 05000445/1979012

Text

b

/an neogs

UN!TED STATES

, y,.

, ,o,,

NUCLEAR REGULATORY COMMISSION

y;

g

E

REGION IV

G?

-:; f

611 RYAN PL AZA DRIVE, SUITE 1000

9,

9 . . . . . ,o#

%

ARLINGl oN, TE X AS 76012

In Reply Refer To:

RIV

Docket No.

50-445/Rpt. 79-12

30-446/Rpt. 79-12

Texas Utilities Generating Company

ATTN:

Mr. R. J. Gary, Executive Vice

President and General Manager

2001 Bryan Tower

Dallas, Texas 75201

Gentlemen:

This refers to tF a investigation conducted by Mr. R. G. Taylor of our staf f on

April 12 through July 20, 1979, of netivities authorized by NRC Construction

Permits No. CPPR-126 and 127 for the Comanche Peak facility, Units No. 1 and 2,

concerning allegations by a former Comanche Peak Employee.

The investigation and our findings are discussed in the enclosed investigation

report.

No items of noncompliance or deviations were identified.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,

Title 10, Code of Federal Regulations,.a copy of this letter and the enclosed

investigation report will be placed in the NRC's Public Docr.atent Room.

If the

report contains any information that you believe to be proprietary, it is

necessary that you submit a written application to this office, within 20 days

of the date of this letter, requesting that such information be withheld from

public disclosure. The application must include a full statement of the reasons

why it is claimed that the information is proprietary.

Ths application should

be prepared so that any proprietary information identified is contained in an

enclosure to the application, since the application without the enclosure will

also be placed in the Public Document Poom.

If we do not hear from you in this

regard within the specified period, the report will be placed in the Public

Document Room.

.

1037

.J

790928063 7

.

Texas Utilities Generating Company

2

August 22, 1979

Should you have any questions concerning this investigation, we will be pleased

to discuss them with you.

Sincerely,

f/

Mb c_

w

W. C. Seidle') Chief

Reactor Conptruction and

Engineci'ing Support Branch

Enclosure:

IE Investigation Report No.

50-445/79-12

50-446/79-12

cc: w/ enclosure

Texas Utilities Generating Company

ATTN:

Mr. H. C. Schmidt, Project Manager

2001 Bryan Tower

Dallas, Texas

75201

.