ML19208D182

From kanterella
Jump to navigation Jump to search
IE Insp Rept 50-255/79-10.Noncompliance Noted:Licensee Does Not Conduct Searches Per Security Plan Commitments.Details Withheld (Ref 10CFR2.790)
ML19208D182
Person / Time
Site: Palisades 
Issue date: 07/24/1979
From: Creed J, Hind J, Madeda T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19208D177 List:
References
50-255-79-10, NUDOCS 7909280088
Download: ML19208D182 (2)


See also: IR 05000255/1979010

Text

.

.

U.S. NUCLEAR REGULATORY COMMISSION

OFFICE OF INSPECTION MiD ENFORCEMENT

i

REGION III

Report No.

50-255/79-10

Docket No. 50-255

License No. DPR-20

Safeguards Group No. IV

Licensee:

Consumers Power Company

212 West Michigan Avenue

Jackson, MI 49201

Facility Name:

Palisades Nuclear Power Plant

Inspection At: Palisades Site, Covart, MI

Inspection Conducted: June 11-15, 1979

Date of Last Physical Security Inspection Visit:

January 22-26, 1979

Type of Inspection: Unannounced Physical Security

.h.

/N

Inspectors

J. Madeda

.

hysi al Se urity Specialist

(Date)

'

J. F. Schaper

%

  • 1!o-Y!W

Physical Security Specialist

(D Ate)'

e#J

g.A. Hind, Chief

,

Approved By:

2,/79

7

Safeguards Branch

(Date)

'

, Inspection Summary

Inspection on June 11-15, 1979 (Report No. 50-255/79-10)

Areas Inspected:

Included review of: Security Plan; Security Program Audit;

Security Organization; Physical Barriers (Protected Area); Physical

Barriers (Vital Area); Lighting; Access Control (Identification, Authorization,

and Badging); Access Control (Search); Access Control (Escorting); Acces:

Control (Vital Areas); Alarm Stations; Detection aids; Assessment aids;

Communications; Testing and Maintenance, Compensatory Measures; Pcuer Supply;

Response; Locks, Keys, and Combinations; Records an'd Reports.

The inspection

involved 85 inspector-hours onsite by two NRC inspectorq.

The inspection was

begun on the da) shift; 24 inspection-hours were accomplished during off-shift

periods.

Results:

Ihe licensee was found to be in compliance with NRC requirements

within the 20 areas examined during the inspection except for the following

6 items:

1051

330

7 9 0928 0Dg'g

~

~

1.

Access Control (Identification Authorization, and Badging) - The

licensee did not conduct proper personnel screening in accordance

with security plan commitments. (Infraction)

2.

Access Control (Search) - The licensee does not conduct searches

in accordance with security plan commitments.

(Infraction)

3.

Detection Aids - One of the perimeter / intrusion alarm systems did not

perform in accordance with security plan commitments.

(Infraction).

4.

Compensatory Measures - The licensee failed to develop and implement

compensatory procedure f6r a piece of security equipment when it

failed.

(Infraction)

5.

Access Control (Identification, Authorization, and Badging) - Licensee

Designated Vehicles were not adequately controlled in accordance with

. security plan commitments.

(Deficiency).

6.

Records and Reports - The security force failed to document all abnormal

occurrences while on security tours.

(Deficiency).

1051

331

.