ML19208C714

From kanterella
Jump to navigation Jump to search
States NRC Understanding of Util Program for Review,Analysis & Repair of Cracks Found in Steam Generator nozzle-to- Feedwater Pipe Welds,As Discussed in 790703 Telcon Between Cw Fay of Util & DC Boyd of NRC
ML19208C714
Person / Time
Site: Point Beach 
Issue date: 07/05/1979
From: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Burstein S
WISCONSIN ELECTRIC POWER CO.
References
NUDOCS 7909270268
Download: ML19208C714 (1)


Text

~

M4EDi ATE' ACTION lETifR

/

o UNITED STATES 8

.,([g NUCLEAR REGULATORY COMMISSION

' $7/.
j REGION 111 o

a 799 ROOSEVELT ROAD g

GLEN ELLYN, ILLINOIS 60137 July 5, 1979 Docket No. 50-301 Wisconsin Electric Power Company ATTN:

Mr. Sol Burstein Executive Vice President Power Plants 231 West Michigan Milwaukee, WI 53201 Cent] emen:

This refers to telephone discussions between Mr. C. W. Fay and Mr. D. C.

Boyd of this office on July 3, 1979, ragarding your program for the review, analysis, and repair of the cracks found in your Unit 2 steam generator nozzle-to-feedwater pipe welds.

The NRC interest and concern in this matter are substantial.

There is a particular interest in assuring that the cause(s) for these failures is analyzed for consideration in the repair and corrective actions program.

It is our understanding that Poi.:t Beach Unit 2 will remain shutdown until:

1.

The repair program and corrective actions have been reviewed with the NRC.

2.

All pertinent information available from the licensee's investiga-tion into the pipe cracking problem have been made available for NRC review.

NRR is aware of, and in agreement with, the above requirements and will be available for this review at your earliest convenience.

P' ease inform us immediately if your understanding of these items is different from that stated above.

Sincerely, Rc s

JamesG.Keppled Director cc:

Mr. G. A. Reed, Manager Central Files

.% roduction Unit NRC 20b 4g jg}

Iocal PDR QC y 9 09 2 7C ZrP Sandra A. Bast, Lakeshore ED! ATE ACWOfFLETTER Citizens for Safe Energy