VIRGINIA ELECTRIC AND PownN CowIwNy Rxcitwowri,Vanoan sA cou61 August 28, 1979 L
Mr. James P. O'Reilly, Director Serial No.
622]
Office of Inspection and Enforcement F0/FHT:baw E
Jo U. S. Nuclear. Regulatory Commission Docket No. 50-338 Region II License No. NPF-4" 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303
Dear Mr. O'Reilly:
, North Anna Power Station Unit 1 In response to the subject Bulletin, " Pipe Cracks in Stagnant Borated Water Systems at PWR Plants", we are performing the review requested to identify applicable piping systems.
However, due to the volume of material that must be reviewed, we will not be able to meet your requested response date of August 25, 1979. We expect our review to be completed within the next two weeks and will provide the results by September 14, 1979.
Very truly yours,
[l([./-
C.M.Sta17ngs Vice President-Power Supply and Production Operations cc: Director Division of Operating Reactors s90.m Q90b0 7909240?>