ML19208A595

From kanterella
Jump to navigation Jump to search
Forwards Amend 30 to License DPR-2,safety Evaluation & Notice of Issuance & Availability
ML19208A595
Person / Time
Site: Dresden Constellation icon.png
Issue date: 08/09/1979
From: Ziemann D
Office of Nuclear Reactor Regulation
To: Reed C
COMMONWEALTH EDISON CO.
Shared Package
ML19208A596 List:
References
NUDOCS 7909170052
Download: ML19208A595 (3)


Text

4, m) tl %,

s"%g UNITED STATES

,,1 NUCLEAR REGULATORY COMMISSION y

Te g

t W ASHINGTON. D. C. PORMB

?

o August 9,1979

%.... /

+

Docket No. 50-10 Mr. Cordell Reed Assistant Vice President Commonwealth Edison Company Post Office Box 767 Chicago, Illinois 60690

Dear Mr. Reed:

The Comission has issued the enclosed Amendment No. 30 to Facility Operating License No. DPR-2 for the Dresden Nuclear Power Station, Unit No.1.

This amendment adds license conditions relating to the completion of facility modifications and implementation of administrative controls for fire protection.

The enclosed Safety Evaluation (SE) addresses your submittals dated October 8, 1976, November 30, 1976, December 28,1976, March 17,1977, March 29,1977, July 19,1977, March 20,1979, May 30,1979, and July 5,1979, and our obser-vations at the Dresden site during the week of March 20-22, 1979.

We have discussed the contents and conditions of this license amendment with members of your staff and we understand that you have agreed to this license amendment.

Nevertheless, you understand that by the provisions of 10 CFR Part 2, Paragraph 2.204, you may demand a hearing with respect to all or any part of the amendment within twenty (20) days from the date of this letter.

If you do not demand a hearing, this amendment will become effective on the expiration of that twenty (20) day period.

By letter dated March 22, 1978 (License Amendment No. 25), we issued Technical Specifications to incorporate limiting conditions for operation and surveillance requirements for existing fire protection systems and administrative controls.

You are requested to propose revised Technical Specifications related to facility modifications described in the enclosed SE and sutxnit them for our review no later than 90 days before the modifications are implemented.

Certain items listed in Section 3.0 of the enclosed SE are marked with an asterisk to indicate that the NRC staff will require additional information in the form of design parameters, test results, or acceptance criteria to assure that the design is acceptable prior to actual implementation for these modifications.

951105 99091'70 0 @

9 A

.g, v

Mr. Cordell Reed August 9,1970 We have detennined that no license amendment fee is required to accompany your response to the aforementioned request. This determination is limited to those applications or requests to incorporate our recommended Technical Specifications and those to add surveillance and other requirements for Any other unrelated operable systems that have been added at our request.

changes or requests that you might choose to include in the fire protection request:; would be subject to amendment fees in accordance with section 170.22 of 10 CFR Part 170.

Copies of the Notice of Issuance and the report of our fire protection consultant, letter from Robert E. Hall to R. L. Ferguson dated July 3,1979, are also enclosed.

Sincerely, QBoh T hh Dennis L. Ziemann,,J ief Operating Reactors Branch #2 Division of Operating Reactors

Enclosures:

1.

Amendment No. 30 to License No. DPR-2 2.

Safety Evaluation 3.

Notice of Issuance 4.

Consultant's Report cc w/ enclosures:

See next page 35110G

u17 Mr. Cordell Reed August 9,1979 cc w/ enclosures:

Isham, Lincoln & Deale Director, Technical Assessment Counselors at Law Division One First National Plaza, 42nd Floor Office of Radiation Programs Chicago, Illinois 60603 (AW-459)

U. S. Environmentsi Protection Mr. B. B. Stephenson Agency Plant Superintendent Crystal Mall #2 Dresden Nuclear Power Station Arlington, Virginia 20460 Rural Route #1 Morris, Illinois 60450 U. S. Environmental Protection Agency V. S. Nuclear Regulatory Commission Federal Activities Branch ATTN:

Jimmy L. Barker Region Y Office P. O. Box 706 ATTN:

EIS COORDINATOR Morris, Illinois 60450 230 South Dearborn Street Chicago, Illinois 60604 Susan N. Sekuler Assistant Attorney General Environmental Control Division 188 W. Randolph Street Suite 2315 Chicago, Illinois 60601 Morris Public Library 604 Liberty Street Morris, Illinois 60451 Chairman Board of Supervisors of Grundy County Grundy County Courthouse Morris, Illinois 60450 Department of Public Health ATTN:

Chief, Division of Nuclear Safety 535 West Jefferson Springfield, Illinois 62761 c J.m s e v~

4.Bt i e