ML19208A085

From kanterella
Jump to navigation Jump to search
Forwards LER 79-071/03L-0
Date released: 08/10/2019 Download: ML19208A085


LER 79-071/03L-0:on 790808,RHR Sys Pump 2D Vibrated at Level Higher than Allowable Limit During RHR Sys Operational Component Test.Caused by Spring Part Lodged in Vane of Impeller.Part Removed,Pump Inspected & Tested
ML19208A096
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 09/06/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19208A096 (2)
Forwards LER 79-071/03L-0
ML19208A084
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 09/06/1979
From: Banks H
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19208A084 (1)