ML19207C220
| ML19207C220 | |
| Person / Time | |
|---|---|
| Site: | Rancho Seco |
| Issue date: | 08/29/1979 |
| From: | Raasch D SACRAMENTO MUNICIPAL UTILITY DISTRICT |
| To: | Doug Garner Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19207C221 | List: |
| References | |
| NUDOCS 7909100499 | |
| Download: ML19207C220 (5) | |
Text
.
esuun
' SACRAMENTO MUNICIPAL UTILITY DISTRICT C 6201 s street, Box 15830 sacramento, California 95a13; (916) 452 3211 August 29, 1979 Mr. Dan Garner Nuclear Reactor Regulation Operator Reactors, Branch No. 4 U. S. Nuclear Regulatory Commission Washington, D. C.
20555
Dear Mr. Garner:
In accordance with the request of your Mr. Earny Sylvester to R. C. Lawrence of our staff, we are submitting the following drawings and information. We understand that this data is to be used in your preparation of a model of our Make-Up Pump Room for fire testing.
DRAWINGS Number Revision Title Comments 48762-3" HE2 6
ISO-Nuclear Service Raw Water DCN 1A-48762-3" HE2 6
IS0-Nuclear Service Shows pipe in-Raw Water sulated for fire protection 48752-3" HE2 5
ISO-Nuclear Service Raw Water DCN 1A-48752-HE2 5
ISO-Nuclear Service Shows pipe in-Raw Water sulated for fire protection DCN 3C-E775 2
Shows detector locations E735-S1 20 Conduit and Tray Shows conduit and Arrangement tray arrangement in Make-Up Pump Room E735-52 1
Conduit and Tray Shows conduit and g
Arrangenent tray arrangement in Make-Up Pump Roca 9r t
p-5 330iG37 9 0 910 0 ff DLo%g5 W o *e, m m m ic mn m-un rm s u.m is m mu u my,
Mr. Dan Garner August 29, 1979 Number Revision Title Comments M 135 10 Auxiliary Piping Shows Make-Up Room Area 3 piping M 136 6
Auxiliary Piping Shows Make-Up Room Area 3 piping M 137 6
Auxiliary Piping Shows Make-Up Room Area 3 piping 6292-M 31.01-118 51 Auxiliary Bldg.
Shows (-) 20 Sprinkler Below Grade supply Sprinklers M 31.01-118, Sheet 2 0
Wet Pipe Sprink-Shows Make-Up Pump ler System Room sprinklers DCN 9 M 424 7
Auxiliary Bldg. HVAC Shows Make-Up Pump Room air exhaust DATA Make-Up Pumo Room Sprinkler Heads Cleveland Automatic #38E (Additional identifying information
-- 38-600ES, 246G-SSU)
Make-Up Pump Room Detectors Pyrotronics Ionization Detectors - Model ISD-5A or ISD-5B Make-Up Pumo Lube Oil System Capacity 25-30 gallons Type oil - Mobile DTE-26 System pressure 25 PSI Service History:
No oil additions between major pump overhauls Make-Up Pump Room HVAC Fire Damper American Warming Model DAF-P-475C, 30" diameter We hope t.his information satisfies your needs; however, if you have any further questions, please do not hesitate to ask.
Sincerely, l } j$dC&
D. G. Raasch, Manager Generation Engineering Department Enclosures D30164