Text
p** "8 coq 4,
UNITED STATES
$, ' ' b
+[
jw
' 'g NUCLEAR REGULATORY COMMISSION
% J-3 REGION V S
5 1990 N. CAllFORNIA BOULEVARD
% ' %'d,8 SUITE 202, WALNUT CREE K PLAZA WALNUT CREEK, CALIFORNIA 94596 August 8, 1979 Docket No. 50-344 Portland General Electric Company 121 S. V. Salmon Street Portlan J, Oregon 972C4 Attention: Mr. Charles Goodwin, Jr.
Assistant Vice President Gentiemen:
TN enclosed Circular 79-15 is forwarded to you for information.
If there are any questions related to your understanding of the suggested t.ctions, please notify NIOSH at the telephone number listed in the enclosure to the Circular.
Sincerely, Jh Mtv t R. H. engelken Director
Enclosures:
1.
IE Circular No. 79-15 2.
Listing of IE Circulars Issued in the Last Six Months cc w/ enclosures:
B. Withers, PGE F. Gaidos, PGE c,,.-
- c.,,
=>.A. s' $ e, L e. 4 7909060
a UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 August 8, 1979 IE Circular No. 79-15 BURSTING OF HIGH PRESSURE HOSE AND MALFUNCTION OF RELIEF VALVE AND "0"-RING IN CERTAIN SELF-CONTAINED BREATHING APPARATUS Description of Circumstances:
The Nuclear Regulatory Commission (NRC) has been informed by mailgram (copy enclosed) frca the National Institute of Occupational Safety and Health (NIOSH) of occurrences of bursting of the high-pressure hose assembly, and malfunction of the relief valve and of the "0"-Ring in the main li~e assembly of the SurvivAir Mark I self-contained bredthing apparatus.
nny one of chese failures would result in i'
" ate loss o' air supply to a user.
Licensees who use the SurvivAir Mark I SCBA should:
1.
Discontinue use of the apparatus until the units have been inspected by the manufacturer and all necessary repairs or replacements have been made.
2.
Contact the manufacturer or supplier of the equipment for instructions on arranging for inspection and repair.
No written response to this circular is required.
If you require additional information regarding this subject, please contact the office specified in the enclosed mailgram.
Enclosure: