ML19207C068

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99900262/79-01 on 790618-21 & Notice of Deviation
ML19207C068
Person / Time
Issue date: 07/16/1979
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Campbell B
BABCOCK & WILCOX CO.
Shared Package
ML19207C065 List:
References
REF-QA-99900262 NUDOCS 7909060404
Download: ML19207C068 (2)


Text

'

MdU

~

fga necqs

+.

o, UNIT ED STATES 8;

j NUCLEAR REGULATORY COMMISSION s.,

gg*3..j REGION IV

. O, '

g 611 RYAN PLAZA OfilVE, SUITE 1000

'O U

o AR LINCTo N, T EXAs 76012 16 Jul,.1979 Lacket No. 99900262/79-01 Bab':ock & Wilcox Control Components, Inc.

Atta:

Mr. R. J. Campbell Acting Executive Officer 2~67 S. E. Main Street Irvine, California 92714 Gentlemen:

1 This refers to the QA Program inspection conducted by Mr. Um. D. Kelley of this office on June 18-21, 1979, of your facility at Irvine, California, associated with the manufacture of ASME Sectica III, "E" Class 1, 2, and 3 valves and to the discussions of our findings with Mr. H. Miller and members of your staff at the conclusion of the inspection.

This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others. You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findings.

Areas examined and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection it was found that the implementation of.your QA Program failed to meet certain NRC requirements. The specific findings and references to the pertinent requirements are identifier 1 in the enclosures to this letter.

Please provide us within thirty (30) days of your receipt of this report a written statement containing, (1) a description of steps that have been or will be taken to correct these items, (2) a description of steps that have been or will be taken to prevent recurrence, and (3) the date your corrective actions and preven-tive measures were or will be completed.

7 9 0 90 6 0 kO((

~

Q 0.i O ? N

Babcock & Wilcox s In accordance with Section 2.790 of the Commission's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter with enclosures and your reply, together with the enclosed inspection report will be placed in the Cocaission's Public Document Rocm.

If this report contains any information that you believe to be proprietary, it is necessary that you make a written application withia thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the infor=ation is propriatary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, l

/

/

Uldia Potapovs, Ch'e Vendor Inspection Branch

,,7,,

Enclosures:

1.

Notice of Deviation 2.

Inspection Report No. 99900262/79-01

. <,. n

'j [ p r...) 9