Notice of Violation from Insp on 780417-21
ML19207B195
Person / Time
Site: Crane  
Issue date: 05/25/1978
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19207B193 List:
References
50-289-78-08, 50-289-78-8, 50-320-78-16, NUDOCS 7908230534
Download: ML19207B195 (2)


Text

'

s APPENDIX,3 NOTICE OF VIOLATION Metropolitan Edison Company Reading, Pennsylvania 19603 Docket No. 50-289 Based on the results of an NRC inspectien conducted on April 17-21, 1978, it appears that certain of your activities were not conducted in full compliance with NRC regulations and the conditions of your NRC Facility License No. DPR-50, as indicated below. ' Item A is categorized as an Infraction.

Items B and C are Deficiencies.

7 A.

10 CFR 20.105(b)(1) "Pemissible levels of radiation in unrestricted areas," requires that radiation levels in unrestricted areas be limited so that if an individual were continuously present in the area, he could not receive a dose in excess of two millirems in any one hour.

Contrary to this requirement, on a number of days, including April 18 and 19,1978, radiation levels existed in an unrestricted area along and outside the fence enclosing the Unit 1 Borated Water Storage Tank (SWST) of up to 10 millirems per hour, such that if an individual had been continuously present in the area, he could have received a dose in excess of two millirems in one hour.

S.

Section 4.4.a and Table 3 of the Environmental Technical Specifi-i- -

cations (ETS) require, in part, that air particulates and air im iodines be sampled and analyzed on a weekly basis at each of the y=

specified locations.

F-(1)

Contrary to these requirements, air particulates were not sampled and analyzed weekly at a number of required locations, including:

TM-AP-lCl May 11 - June 1, 1977 TM-AP-lS2 May 15 - June 8, 1977 TM-AP-1231 June 8 - June 22, 1977 TM-AP-5Al August 17 - September 7, 1977 (2)

Contrary to these requirements, air iodines were not sampled and analyzed weekly at a number of required stations, including:

TM-AI-lS2 May 11 - June 8, 1977 TM-AI-5Al August 17 - September 7, 1977.

=

7908230539'

%,.e*-

..ra ;-x ----.. _ _--

.: -:-m p&=a T.i'-hht-4Et ?;:L22WEC -%'a ' Fn'. 7F." 6_ ~c ~ d 7 22-2 -e

. h i,:+ r 2 - e y m. g. g==- y g - i; m.

w-

~ - :- - ;-._,: :..

- --.~ ::
7. _ _~.m -g-z

~

Appendix A 2

C.

Section 4.4.a and Table 3 of the ETS require, in part, that water samples collected at the City of Columbia water intake be analyzed with sufficient sensitivity to meet the minimum analytical sensi-tivities specified in Table 3.

Contrary to these requirements, the water samples, collected from the City of Columbia water intake during the Second, Third and Fourth Quarters of 1977, were not analyzed with sufficient analyt-ical sensitivity to meet the specified minimum sensitivity for Sr-89.