July 23, 2019
Mr. Frank Payne
Site Vice President
FirstEnergy Nuclear Operating Company
Perry Nuclear Power Plant
Reg Affairs-A210
10 Center Road, P.O. Box 97
Perry, OH 44081-0097
SUBJECT: PERRY NUCLEAR POWER PLANT, UNIT 1NOTIFICATION OF AN NRC
TRIENNIAL HEAT SINK PERFORMANCE INSPECTION AND REQUEST FOR
INFORMATION; INSPECTION REPORT 05000440/2019004
Dear Mr. Payne:
On December 2, 2019, the U.S. Nuclear Regulatory Commission (NRC) will begin the onsite
portion of the Triennial Heat Sink Performance inspection at your Perry Nuclear Power Plant,
Unit 1. This inspection will be performed in accordance with NRC baseline Inspection
Procedure 71111.07.
In order to minimize the impact that the inspection has on the site and to ensure a productive
inspection, we have enclosed a request for documents needed for the inspection. The
documents have been divided into two groups.
The first group lists information necessary for our initial inspection scoping
activities. This information should be available to the lead inspector no later than
September 16, 2019. By September 20, 2019, the inspector will communicate the initial
selected set of approximately 2-3 risk significant heat exchangers.
The second group is needed to support our in-office preparation activities. This set of
documents, including the calculations associated with the selected heat exchangers,
should be available to the inspector no later than November 18, 2019. This information
should be separated for each selected component, especially if provided electronically
(e.g., folder with component name that includes calculations, condition reports,
maintenance history, etc). During the in-office preparation activities, the inspector
may identify additional information needed to support the inspection.
It is also requested that corrective action documents and/or questions developed during the
inspection be provided to the inspector as the documents are generated.
All requested documents are to be for the time period from the onsite inspection period back
to the documents that were provided in response to the previous Heat Sink Performance
Inspection. If no activities were accomplished in that time period, then the request applies to
the last applicable document in the previous time period. It is important that these documents
be as complete as possible, in order to minimize the number of documents requested during
the preparation week or during the onsite inspection.
F. Payne
-2-
The lead inspector for this inspection is Lionel Rodriguez. We understand that our licensing
contact for this inspection is George Dujanovic of your organization. If there are any questions
about the inspection or the material requested in the enclosure, please contact the lead
inspector at 630-829-9609 or via e-mail at Lionel.Rodriguez@nrc.gov.
This letter does not contain new or amended information collection requirements subject
to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information
collection requirements were approved by the Office of Management and Budget, Control
Number 3150-0011. The NRC may not conduct or sponsor, and a person is not required to
respond to, a request for information or an information collection requirement unless the
requesting document displays a currently valid Office of Management and Budget Control
Number.
This letter and its enclosure will be made available for public inspection and copying at
http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in
accordance with 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely,
/RA Jorge Corujo-Sandin Acting for/
Lionel Rodriguez, Reactor Engineer
Engineering Branch 2
Division of Reactor Safety
Docket No. 50-440
License No. NPF-58
Enclosure:
Document Request for Triennial Heat Sink
Performance Inspection
cc: Distribution via LISTSERV
F. Payne
-3-
Letter to Frank Payne from Lionel Rodriguez dated July 23, 2019.
SUBJECT: PERRY NUCLEAR POWER PLANT, UNIT 1NOTIFICATION OF AN NRC
TRIENNIAL HEAT SINK PERFORMANCE INSPECTION AND REQUEST
FOR INFORMATION; INSPECTION REPORT 05000440/2019004
DISTRIBUTION:
RidsNrrPMPerry Resource
RidsNrrDorlLpl3
RidsNrrDirsIrib Resource
DRPIII
DRSIII
ADAMS Accession Number: ML19205A425
OFFICE
RIII
NAME
JCorujo-Sandin for
LRodriquez:cl
DATE
07/23/19
OFFICIAL RECORD COPY
DOCUMENT REQUEST FOR TRIENNIAL HEAT SINK PERFORMANCE INSPECTION
Enclosure
Inspection Report: 05000440/2019004
Inspection Dates:
December 2-6, 2019
Inspection Procedure:
71111.07, Heat Sink Performance
Lead Inspector:
630-829-9609
Lionel.Rodriguez@nrc.gov
Please provide the information electronically in pdf files, Excel, or other searchable formats,
preferably on some portable electronic media (e.g., CD-ROM, DVD). The portable electronic
media should contain descriptive names, and be indexed and hyperlinked to facilitate ease of
use. The information can also be provided via an internet file sharing system, so long as the
inspectors are provided access to the system throughout the inspection process and the system
allows the files to be downloaded. Information in lists should contain enough information to be
easily understood by someone who has knowledge of light water reactor technology.
I.
Information Requested By September 16, 2019
1.
List of the Generic Letter (GL) 89-13, Service Water System Problems Affecting
Safety-Related Equipment, heat exchangers in order of risk significance.
2.
Copy of heat exchanger performance trending data tracked for each GL 89-13
heat exchanger.
3.
List of Corrective Action Program (CAP) documents (with a short description)
associated with GL 89-13 heat exchangers, heat sinks, silting, corrosion, fouling,
aging, heat exchanger testing, ultimate heat sink (UHS), and safety-related
service water systems for the previous 3 years or since the last CAP document
list was sent to the U.S. Nuclear Regulatory Commission for the Previous Heat
Sink Performance Inspection. The list should include all CAP documents not on
the last CAP document list.
4.
Copy of any self-assessment done on any of the GL 89-13 heat exchangers,
UHS, and safety-related service water systems since the last Heat Sink
Performance Inspection.
5.
Last two System Health Report(s) and maintenance rule system notebooks for all
the GL 89-13 heat exchangers, UHS, and safety-related service water systems.
6.
List of engineering-related operator workarounds (with a short description)
associated with GL 89-13 heat exchangers. The requested documents are to be
for the time period from the onsite inspection period back to the documents that
were provided in response to the previous Heat Sink Performance Inspection.
DOCUMENT REQUEST FOR TRIENNIAL HEAT SINK PERFORMANCE INSPECTION
2
7.
List of permanent and temporary modifications (with a short description)
associated with GL 89-13 heat exchangers, UHS, and safety-related service
water systems. The requested documents are to be for the time period from the
onsite inspection period back to the documents that were provided in response to
the previous Heat Sink Performance Inspection.
8.
Electronic copies of the current Final Safety Analysis Report, Technical
Specifications, Technical Specifications Basis, and Technical Report Manual.
II.
Information Requested By November 18, 2019
1.
Copies of the GL 89-13 responses.
2.
Copies of procedures developed to implement the recommendations of GL 89-13
(e.g., the GL 89-13 Heat Exchanger Program description).
3.
A schedule of all inspections, cleanings, maintenance, or testing of any
safety-related plant heat exchanger to be performed during the onsite portion
of the inspection.
4.
For the specific heat exchangers selected:
a.
Copy of system description and design basis document for the heat
exchangers (as applicable).
b.
Copy of the design specification, heat exchanger data sheets, and vendor
documents including component drawings applicable for the selected
heat exchangers.
c.
Copies of normal, abnormal, and emergency operating procedures
associated with the selected heat exchangers.
d.
Copy of the operating procedure that ensures that the maximum cooling
water system inlet temperature limit is not exceeded.
e.
Copies of the Aging Management Programs (AMP) and the
implementing procedures that manage aging of the selected heat
exchangers (as applicable).
f.
Information regarding any alarms which monitor on-line performance.
g.
Copy of the document which identifies the current number of tubes in
service for each heat exchanger.
h.
Provide a list of calculations (with a short description) which currently
apply to each heat exchanger.
i.
Provide the calculations or evaluations that:
i.
establish the limiting (maximum) design basis heat load required
to be removed by each of these heat exchangers;
DOCUMENT REQUEST FOR TRIENNIAL HEAT SINK PERFORMANCE INSPECTION
3
ii.
demonstrate the heat exchangers capacity to remove the limiting
heat load;
iii.
correlate surveillance testing and/or inspection results from
these heat exchangers with design basis heat removal capability
(e.g., basis for surveillance test and/or inspection acceptance
criteria);
iv.
establish the maximum number of tubes which can be plugged in
each heat exchanger;
v.
evaluate the potential for water hammer in each heat exchanger
or associated piping; and
vi.
evaluate excessive tube vibration in each heat exchanger and the
documents that describe the controls that prevent heat exchanger
degradation due to excessive flow induced vibration during
operation.
j.
Copies of the two most recent completed tests and evaluation data
confirming thermal performance for those heat exchangers which are
performance tested. Include documentation and procedures that
identify the types, accuracy, and location of any special instrumentation
used for the two most recently completed thermal performance tests for
the heat exchangers (e.g., high accuracy ultrasonic flow instruments or
temperature instruments). Include calibration records for the instruments
used during these tests.
k.
Copy of the document describing the inspection results of each heat
exchanger. The requested documents are to be for the time period from
the onsite inspection period back to the documents that were provided in
response to the previous Heat Sink Performance Inspection.
l.
The thermal performance testing, cleaning, and inspection maintenance
schedule for each heat exchanger for the next 5 years.
m.
Copy of the periodic flow testing at or near maximum design flow.
The requested documents are to be for the time period from the onsite
inspection period back to the documents that were provided in response
to the previous Heat Sink Performance Inspection.
n.
Copies of those documents that describe the methods taken to control
water chemistry in the heat exchangers.
o.
Copies of the documents that verify the structural integrity of the heat
exchanger (e.g., eddy current summary sheets, ultrasonic testing results,
and visual inspection results).
p.
Copy of any operability determinations or other documentation of
degradation associated with the heat exchangers or the systems that
support the operation for the selected heat exchangers.
DOCUMENT REQUEST FOR TRIENNIAL HEAT SINK PERFORMANCE INSPECTION
4
5.
For the UHS and the safety-related service water systems (or equivalent):
a.
Copy of system description and design basis document (as applicable).
b.
Copy of any operability determinations or other documentation of
degradation associated with the UHS and the safety-related service
water systems.
c.
Copy of the document (e.g., Updated Final Safety Analysis Report or
Technical Requirements Manual) that states the maximum cooling water
system inlet temperature limit that still allows full licensed power operation
of the nuclear reactor.
d.
Copy of the construction code and design specification.
e.
Copies of normal, abnormal, and emergency operating procedures
associated with the UHS and safety-related service water systems
including procedures for loss of these systems.
f.
Copies of the AMPs and the implementing procedures that manage aging
of the UHS (including the intake structure) and the safety-related service
water systems (as applicable).
g.
Copies of CAP documents associated with waterhammer or hydraulic
transients in the safety-related service water systems since the last Heat
Sink Performance Inspection.
h.
If available, provide an electronic copy of piping and instrumentation
diagrams for the safety-related service water systems, including the
intake structure.
i.
Provide a list of calculations (with a short description), which currently
apply to UHS and safety-related service water systems.
j.
Provide a list of instruments (with a short description) associated with
automatic or alarm functions for the UHS and safety-related service water
systems.
k.
Provide a list of any design change (with a short description) performed
on the UHS or safety-related service water systems since the last Heat
Sink Performance Inspection.
l.
For the review of the performance testing of the safety-related service
water system (or equivalent) and the UHS:
i.
Copies of the last two performance tests, such as the
American Society of Mechanical Engineers inservice test, for
the pumps, valves, and, if applicable, the cooling tower fans in
the safety-related service water system. If the components are
not performance tested, please provide documentation verifying
performance by the methods actually used.
DOCUMENT REQUEST FOR TRIENNIAL HEAT SINK PERFORMANCE INSPECTION
5
ii.
Copies of the documents that demonstrate that flow balance
testing was performed during the last 3 years. If the last flow test
was performed longer than 3 years, then provide the last flow test.
iii.
Copies of the documents that demonstrate that flow balance
testing will continue to be periodically done in the future.
iv.
Copies of procedures used to monitor interface valves between
the safety related section of the service water system and the
nonsafety-related section. Include completed results of the
monitoring. The requested documents are to be for the time
period from the onsite inspection period back to the documents
that were provided in response to the previous Heat Sink
Performance Inspection.
v.
Copies of the procedures that verify the performance of risk
significant non-safety functions of the safety-related service water
system (or equivalent) and the UHS. Include completed results of
the verifications. The requested documents are to be for the time
period from the onsite inspection period back to the documents
that were provided in response to the previous Heat Sink
Performance Inspection.
m.
For the review associated with the system walkdown of the service water
intake structure:
i.
Copies of corrective maintenance for the last 6 years associated
with service water strainers, traveling screens and trash racks.
ii.
Copies of the last two inspections and/or surveillances associated
with service water strainers, traveling screens and trash racks.
iii.
List of preventive maintenance, including frequency, associated
with service water strainers, traveling screens and trash racks.
iv.
Copies of abnormal procedures for the traveling screens and
service water strainers.
v.
Copies of the last two inspections and/or surveillances
documenting that component mounts have not excessively
degraded (i.e., due to corrosion). For example, inspections for the
mounts for the, service water pumps, service water strainers,
traveling screens and trash racks.
vi.
Copies of the documents associated with the monitoring, trending,
and remediation of silt accumulation at the service water pump
bay.
DOCUMENT REQUEST FOR TRIENNIAL HEAT SINK PERFORMANCE INSPECTION
6
vii.
Copies of surveillance procedures and testing results performed
on the service water pump bay water level instruments. The
requested documents are to be for the time period from the onsite
inspection period back to the documents that were provided in
response to the previous Heat Sink Performance Inspection.
viii.
Copies of procedures associated with operating during adverse
weather conditions (e.g., icing, high temperatures, or low level).
ix.
Copy of the evaluation for the potential effects of low flow/level
on underwater weir walls intended to limit silt or sand intake, if
applicable.
x.
Copies of any credited AMP monitoring/inspection results for
the intake structure, including components within the intake
structure (as applicable). For example, documentation of intake
structure inspections performed under the Structures Monitoring
AMP. The requested documents are to be for any completed
monitoring/inspection in the time period from the onsite inspection
period back to the documents that were provided in response to
the previous Heat Sink Performance Inspection.
If the information requested above will not be available by the dates specified, please contact
Lionel Rodriguez as soon as possible at 630-829-9609 or e-mail Lionel.Rodriguez@nrc.gov.