HOLTEC Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 T E R IA TI 0 1 AL June 14, 2019 Yen Chen, Project Manager - Licensing Branch Division of Spent Fuel Management

  • Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032

Reference:

[l]

"Acceptance Review of Request for Amendment No. 5 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Cask System -

Request for Supplemental Information" (Letter from Yen Chen (NRC) to Joyce Tomlinson (Holtec) dated February 13, 2019)

[2]

"Response to HI-STORM FW Amendment 5 RSis" (Letter from Joyce Tomlinson (Holtec) to Yen Chen (NRC) dated April 1, 2019.

Subject:

Supplemental Information to HI-STORM FW Amendment 5 RSis 8-1 and 11-1

Dear Ms. Chen:

By letter dated April 1, 2019 [2], Holtec responded to the NRC's request for additional information (RSis) [l] needed to complete their acceptance review of HI-STORM FW Amendment 5 to the Certificate of Compliance No. 1032. Following the phone call between NRC staff and Holtec, May 14, 2019, Holtec agreed to provide additional information to clarify the responses to RSI 8-1 and RSI 11-1. Attachment 1 contains the additional infom1ation in response to the RSis. Attachment 2 contains the non-proprietary HI-STORM FW FSAR changed pages with changes specific to this supplemental response highlighted in yellow. There is no proprietary information contained on these pages.

Please contact me at (856)797-0900 extension 3765 if you have any questions or require any additional information.

Document ID 5018068 Page I of2

HOLTEC INTER ' AT I O t AL Sincerely, Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 e0--*---

Joyce Tomlinson Adjunct Licensing Manager Holtec International cc:

(letter only without attachments)

Mike Layton (NRC)

John McKirgan (NRC)

Attachments: : Supplemental Information to Response to RSls 8-1 and 11-1 on HI-STORM FW Amendment 5 (non-proprietary) : HI-STORM FW FSAR (Proposed Rev. 5.G), changed pages (non-proprietary)

Document ID 5018068 Page 2 of2