ML19169A245
| ML19169A245 | |
| Person / Time | |
|---|---|
| Site: | Salem (DPR-70, DPR-75) |
| Issue date: | 06/13/2019 |
| From: | Duke P Public Service Enterprise Group |
| To: | James Kim Plant Licensing Branch 1 |
| References | |
| L-2019-LLA-0018 | |
| Download: ML19169A245 (3) | |
Text
1 NRR-DRMAPEm Resource From:
Duke, Paul R. <Paul.Duke@pseg.com>
Sent:
Thursday, June 13, 2019 3:03 PM To:
Kim, James Cc:
Thomas, Brian J.
Subject:
[External_Sender] RE: Confirmation on: RAI Response for Salem TSTF-547 LAR Jim, see below for our confirmation. Please let us know if you need any other information.
Paul PSEGSC From: Kim, James [1]
Sent: Wednesday, June 12, 2019 9:24 AM To: Thomas, Brian J.
Cc: Duke, Paul R.
Subject:
[EXTERNAL] FW: Confirmation on: RAI Response for Salem TSTF-547 LAR Email sent from outside of PSEG. Use caution before using links/attachments.
- Brian, See Dr. Pengs email shown below. He would like to get a confirmation on a couple of items shown below.
- Thanks, Jim Kim From: Peng, Shie-Jeng Sent: Wednesday, June 12, 2019 9:15 AM To: Kim, James <James.Kim@nrc.gov>
Cc: Peng, Shie-Jeng <Shie-Jeng.Peng@nrc.gov>
Subject:
Confirmation on: RAI Response for Salem TSTF-547 LAR
- Jim, I have reviewed the RAI response as well as the relevant TS amendments etc. I would like to have a confirmation from the licensee that:
- 1. The 50% power and 6 steps of rod motion restrictions are originated from the concern that the analog rod position indicators (ARPI) are susceptible to drift due to thermal transients. (Ref. 5-22-89 Supplement),
Confirmation: The ** footnote proposed in the May 22, 1989 supplement and added to the Salem TS by Amendment 103-80 was added to address the de-calibration (drift) of the Analog Rod Position Indication (ARPI) due to thermal effects following rod motion.
- and,
- 2. The allowed one hour thermal socked time is sufficient to let the above mentioned thermal transients and associated ARPI drift be reduced to reaching an equilibrium state. (TSTF-547).
2 Confirmation: As discussed in Salem Amendments 78-43 and 103-80, the one hour soak period currently in the Salem TS and proposed in TSTF-547 is sufficient time to allow the ARPI indication to reach equilibrium such that the rod position of the ARPI can be compared to the group demand counters and verify that rods are within the insertion limits.
Your help would be appreciated.
Peng From: Kim, James Sent: Wednesday, June 12, 2019 7:32 AM To: Peng, Shie-Jeng <Shie-Jeng.Peng@nrc.gov>
Subject:
FW: RE: RAI Response for Salem TSTF-547 LAR Dr. Peng, The licensee has provided your requested Amendments and submittal letters.
Thanks, Jim Kim The information contained in this e-mail, including any attachment(s), is intended solely for use by the named addressee(s). If you are not the intended recipient, or a person designated as responsible for delivering such messages to the intended recipient, you are not authorized to disclose, copy, distribute or retain this message, in whole or in part, without written authorization from PSEG. This e-mail may contain proprietary, confidential or privileged information. If you have received this message in error, please notify the sender immediately. This notice is included in all e-mail messages leaving PSEG. Thank you for your cooperation.
Hearing Identifier:
NRR_DRMA Email Number:
57 Mail Envelope Properties (2187d93e31834ef7880cfefa754a88ee)
Subject:
[External_Sender] RE: Confirmation on: RAI Response for Salem TSTF-547 LAR Sent Date:
6/13/2019 3:03:16 PM Received Date:
6/13/2019 3:03:31 PM From:
Duke, Paul R.
Created By:
Paul.Duke@pseg.com Recipients:
"Thomas, Brian J." <Brian.Thomas@pseg.com>
Tracking Status: None "Kim, James" <James.Kim@nrc.gov>
Tracking Status: None Post Office:
pseg.com Files Size Date & Time MESSAGE 2935 6/13/2019 3:03:31 PM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: