8 to Updated Final Safety Analysis Report, Chapter 3, Appendix 3D, Containment Tendon Anchorage Hardware Capacity Tests
ML19150A450
Person / Time
Site: Ginna 
(DPR-018)
Issue date: 05/10/2019
From:
Exelon Generation Co, Pittsburgh Testing Lab
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19150A453 List: ... further results
References
Download: ML19150A450 (36)


Text

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 668 of 769 Revision 28 5/2019 APPENDIX 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS by PITTSBURGH TESTING LABORATORY

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 669 of 769 Revision 28 5/2019 Compressive Load Tests of 90 Wire Tendon Base Plate - Test on Concrete Stand

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 670 of 769 Revision 28 5/2019 Sheet 2 of Report

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 671 of 769 Revision 28 5/2019 Sheet 3 of Report

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 672 of 769 Revision 28 5/2019 Sheet 4 of Report

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 673 of 769 Revision 28 5/2019 Compressive Load Tests of 90 Wire Tendon Base Plate - Test on Concrete Stand

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 674 of 769 Revision 28 5/2019 Sheet 2 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 675 of 769 Revision 28 5/2019 Sheet 3 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 676 of 769 Revision 28 5/2019 Sheet 4 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 677 of 769 Revision 28 5/2019 Sheet 5 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 678 of 769 Revision 28 5/2019 Sheet 6 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 679 of 769 Revision 28 5/2019 Sheet 7 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 680 of 769 Revision 28 5/2019 Sheet 8 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 681 of 769 Revision 28 5/2019 Compression Tests of 90-Wire Anchor Head Assembly

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 682 of 769 Revision 28 5/2019 Sheet 2 of Report

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 683 of 769 Revision 28 5/2019 Compression Tests of 90-Wire Anchor Head Assembly

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 684 of 769 Revision 28 5/2019 Sheet 2 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 685 of 769 Revision 28 5/2019 Sheet 3 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 686 of 769 Revision 28 5/2019 Sheet 4 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 687 of 769 Revision 28 5/2019 Sheet 5 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 688 of 769 Revision 28 5/2019 Sheet 6 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 689 of 769 Revision 28 5/2019 Sheet 7 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 690 of 769 Revision 28 5/2019 Load Tests of Coupler and Adaptor 90-11

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 691 of 769 Revision 28 5/2019 Sheet 2 of Report

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 692 of 769 Revision 28 5/2019 Load Tests of Coupler and Adaptor 90-11

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 693 of 769 Revision 28 5/2019 Sheet 2 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 694 of 769 Revision 28 5/2019 Sheet 3 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 695 of 769 Revision 28 5/2019 Sheet 4 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 696 of 769 Revision 28 5/2019 90 Wire Tendon Test

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 697 of 769 Revision 28 5/2019 90 Wire Tendon Test

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 698 of 769 Revision 28 5/2019 90 Wire Tendon Test

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 699 of 769 Revision 28 5/2019 Sheet 2 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 700 of 769 Revision 28 5/2019 Sheet 3 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 701 of 769 Revision 28 5/2019 Sheet 4 of Notes

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 702 of 769 Revision 28 5/2019 Load Tests of 90-X7 Coupler

GINNA/UFSAR Appendix 3D CONTAINMENT TENDON ANCHORAGE HARDWARE CAPACITY TESTS Page 703 of 769 Revision 28 5/2019 Sheet 2 of Report