From: Rowley, Jonathan To: PETERS Gary (Framatome)
Cc: HOTTLE Nathan (Framatome); HOLM Jerald (EXTERNAL Framatome)
Subject:
RAIs for ANP-10337 Date: Wednesday, May 15, 2019 11:32:00 AM Attachments: ANP-10337 Supp 1 RAIs.pdf Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome Inc.
3315 Old Forest Road Lynchburg, VA 24501
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING FRAMATOME INC.
TOPICAL REPORT ANP-10337P, REVISION 0, SUPPLEMENT 1P, REVISION 0, DEFORMABLE SPACER GRID ELEMENT (EPID: L2018TOP0037)
Dear Mr. Peters:
By letter dated September 21, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession Number ML18268A141), Framatome, Inc. (Framatome) submitted for U.S. Nuclear Regulatory Commission (NRC) staff review and approval Topical Report (TR) ANP-10337, Revision 0, Supplement 1P, Revision 0, Deformable Spacer Grid Element. Upon review of the information provided, the NRC staff has determined that additional information is needed to complete the review. On May 13, 2019, Jerald Holm, Framatome Licensing Engineer, and I agreed that the NRC staff will receive the response to the attached Request for Additional Information (RAI) questions by September 27, 2019.
If you have any questions regarding the enclosed RAI questions, please contact me at 3014154053.
Jonathan Rowley, Project Manager U.S. Nuclear Regulatory Commission (NRC)
Office of Nuclear Reactor Regulation (NRR)
Division of Licensing Projects (DLP)
Licensing Processes Branch (PLPB)
Phone: 301-415-4053 Email: jonathan.rowley@nrc.gov